background image

REPLACING THE VEIN TUBING SYSTEM

1. 

Start installing the new tubing on the left side 

of the hand. Leave about 12" of excess tubing 

out of the vein channel. 

(See Figure 1.)

2. 

The vein will follow the channel around the 

ring finger back down along the middle of 

the hand. 

(See Figure 2.) 

The vein continues 

around the lower loop at the wrist, back up 

around the thumb, and around the upper loop 

at the wrist. 

(See Figure 3.)

 Now the vein will 

overlap itself at the middle of the hand and continue around the middle finger. 

(See Figure 4.)

3. 

The vein will now go around the loop at the back of the hand and continue around the index finger. 

(See Figure 5.)

 Now run the vein down the channel to the wrist (the vein will overlap the two loops at 

the wrist) and out the end of the vein channel on the bottom of the wrist.

REMOVING THE SKIN AND VEINS

1. 

Remove the two thumb screws that 

hold the hand on the stand.  

(See Figure 7.)

2. 

Remove the old skin by cutting it with 

a pair of sharp scissors. Start at the 

wrist and cut up to the end of the 

middle finger. Carefully peel the old 

skin off the core and discard it.

3. 

Remove the old “veins” from the 

grooves and discard them.

REPLACING THE HAND SKIN

1. 

Pour a portion of the lubricant into the skin, allowing the lubricant to run down the sides (pour only 

enough lubricant into the skin to completely coat the inside surface).

2. 

Squeeze the skin between your hands. Work your hands back and forth, up and down the skin to 

coat the inside of the skin thoroughly with the lubricant.

3. 

Grasping the skin as illustrated, slide the skin down over the core until the fingers are approaching 

the finger holes. 

(See Figure 6.)

 

CAUTION: 

Work the skin on gently — pulling hard on the end of the skin can stretch or tear the 

material.

4. 

As the skin is worked down over the core, be sure the tubing remains in the channels.

5. 

Guide the fingers and thumb carefully into the proper holes as the skin is slipped further down on 

the core. If you encounter difficulty, simply slide the skin back an inch or two from the fingers and 

begin again.

6. 

After the fingers are positioned in the hand, slide the skin over the remainder of the core to provide a 

snug fit.

7. 

If air is trapped in the fingers, a 22-gauge needle can be used to puncture the fingertip and allow the 

air to escape.

POSITIONING THE TUBING

Feel along the tubing channel to be certain that the tubing is properly seated. If it has slipped out of its 

channel while the skin was being pulled on, it can usually be moved back into position by working it with 

your fingers on the outside of the skin.
The ends of the tubing should emerge from the two holes provided in the skin at the bottom of the wrist.

FINISHING INSTALLATION

Pull the skin snugly over the core. Check to be sure that the tubing has not become kinked. This can be 

done by blowing air in one end of the tubing and checking for air flow out the other end.

Warm water should be used to rinse  away any excess lubricant remaining 

on the surface of the skin. Attach the hand to the stand with the thumb screws. 

(See Figure 7.)

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7

Actual product may vary slightly from photo. Nasco reserves the right to change product color, materials, 

supplies, or function as needed.

HC190001INM17.indd   3-4

3/11/19   1:08 PM

Содержание LF01140U

Страница 1: ...F01140U LightSkin LF01147U DarkSkin LF01141U Vein INSTRUCTION MANUAL WARNING Products may contain dry natural rubber Other Available Simulators LF00698U Adult Injectable Arm Light LF00958U Pediatric Injectable Arm LF00995U Arterial Puncture Arm LF01121U Advanced IV Arm LF01131U Venipuncture and Injection Arm LF01139U Advanced IV Hand LF00698U LF00995U LF01121U HC190001INM17 indd 1 2 3 11 19 1 08 P...

Страница 2: ...slide the skin down over the core until the fingers are approaching the finger holes See Figure 6 CAUTION Work the skin on gently pulling hard on the end of the skin can stretch or tear the material 4 As the skin is worked down over the core be sure the tubing remains in the channels 5 Guide the fingers and thumb carefully into the proper holes as the skin is slipped further down on the core If yo...

Страница 3: ...slide the skin down over the core until the fingers are approaching the finger holes See Figure 6 CAUTION Work the skin on gently pulling hard on the end of the skin can stretch or tear the material 4 As the skin is worked down over the core be sure the tubing remains in the channels 5 Guide the fingers and thumb carefully into the proper holes as the skin is slipped further down on the core If yo...

Страница 4: ...F01140U LightSkin LF01147U DarkSkin LF01141U Vein INSTRUCTION MANUAL WARNING Products may contain dry natural rubber Other Available Simulators LF00698U Adult Injectable Arm Light LF00958U Pediatric Injectable Arm LF00995U Arterial Puncture Arm LF01121U Advanced IV Arm LF01131U Venipuncture and Injection Arm LF01139U Advanced IV Hand LF00698U LF00995U LF01121U HC190001INM17 indd 1 2 3 11 19 1 08 P...

Отзывы: