LoRaWAN™ BK-G Pulse Reader

CM3060

TROUBLESHOOTING

If the device did not register to the network, it can be for 2 
reasons: 
• The device is not allowed in the network and it must be 
registered with the service provider.
The necessary data is on a separate sticker in the package 
(DevEUI, AppEUI, AppKey). Once the device is registered 
repeat the switching on procedure described under point 2. 
• There is no LoRaWAN reception. Contact your LoRaWAN 
service provider.

3

BK-G PULSE READER INSTALLATION

Install the reader to the gas meter as indicated on the 
diagram. Fasten the reader and attach the antenna. 

1

SWITCHING ON

Hold the magnet against the device (see illustration below) 
for at least 1 second.

• The sensor starts to initialize and the red light will flash 
(at least 5 seconds).
- If the sensor failed to initialize the red light will stay on for 
5 sec. 
• Otherwise it will try to register to the network and the 
green light is flashing (at least 5 sec).
- If it failed to join, the red light will stay on for 5 sec. 
• If the network join was succesful, the green light will 
stay on for 5 sec.

2

Nordic Automation Systems

www.nasys.no

[email protected]