LoRaWAN™ BK-G Pulse Reader
CM3060
TROUBLESHOOTING
If the device did not register to the network, it can be for 2
reasons:
• The device is not allowed in the network and it must be
registered with the service provider.
The necessary data is on a separate sticker in the package
(DevEUI, AppEUI, AppKey). Once the device is registered
repeat the switching on procedure described under point 2.
• There is no LoRaWAN reception. Contact your LoRaWAN
service provider.
3
BK-G PULSE READER INSTALLATION
Install the reader to the gas meter as indicated on the
diagram. Fasten the reader and attach the antenna.
1
SWITCHING ON
Hold the magnet against the device (see illustration below)
for at least 1 second.
• The sensor starts to initialize and the red light will flash
(at least 5 seconds).
- If the sensor failed to initialize the red light will stay on for
5 sec.
• Otherwise it will try to register to the network and the
green light is flashing (at least 5 sec).
- If it failed to join, the red light will stay on for 5 sec.
• If the network join was succesful, the green light will
stay on for 5 sec.
2
Nordic Automation Systems
www.nasys.no
1
2