3.2 Installation of control unit
- The control unit can be installed either in the sauna or in the dressing room. In the
sauna the control unit shall be installed at a height of at most 65 cm. Cf. Fig. 5.
- Install the stand for the control unit on the wall and the control unit on the stand. Fig. 5.
- The wiring of the control unit can be shortened. The wire may not be inserted in
the connection box of the stove.
- Surface installation of control unit into contact box. Fig. 6.2.
min. 20 cm
m
ax
6
5
cm
Installation of control unit on
the wall. NOTE! The control unit
must not be installed in a wall
recess.
Fig. 5.
Use little
screwdriver
when you open
the cover. Push
with screwdriver
salients in. In the
picture arrows
shows where
salients are.
Fig. 6.1
Surface installation of control unit
in dressing room.
Fig. 8.
Surface installation of control unit in sauna.
Fig. 7.
Control unit
Fig. 9.
Surface installation of control unit
into contact box.
Fig. 6.2
4. CONTROL UNIT
4.1 Instructions for use of control unit
1. On/Off pushbutton
• When the display is off, pushing this button will switch on the control unit
and the stove. The button shall be held down for more than 1 second.
• The control unit and the stove can be switched off by pressing the button again
and holding it down (for more than 1 second).
• When the stove is switched on, the pre-selection time will be displayed
(yellow LED is on).
The pre-selection time remains on the display for 5 seconds, and then
the measured temperature is displayed (basic status).