4.3 EXAMPLES
The desired temperature in the sauna is about 100 °C and the heater is desired to be switched
on for 2.5 hours at a time.
1. Switch on the power using the I/O button.
2. Depress the SET button -> the yellow LED flashes.
3. Depress the SET button a second time -> the green LED flashes.
4. Depress the + or - button several times until the reading 2:30 is displayed.
5. Depress the SET button -> the red LED flashes.
6. Depress the + or - button several times until the sign P14 is displayed.
7. Depress the SET button -> the heater is switched on and the set values will be saved for
the next time.
You wish to switch on the heater in about 3 hours
1. Switch on the power using the I/O button.
2. Depress the SET button -> the yellow LED flashes.
3. Depress the + or - button several times until the reading 3:00 will be displayed.
4. Depress the SET button -> the green LED flashes.
5. If you want to keep the set power-on time, depress the SET button; to change the power-on time,
use the + or - buttons
6. The red LED will flash after the SET button has been depressed. If you wish to set the temperature,
you can use the + or - buttons; if not, just depress the SET button to turn the pre-set timing on.
4.2 SETTINGS
-
When the heater is switched on, the power-on time, which will be saved in memory, can be set within
about 1 minute. After this, the heater goes into its normal operating mode, and any subsequent
settings of the power-on time will only affect the current heating session.
- When the SET button is depressed, the yellow LED will flash, and an array of zeros will be displayed.
-
After this, the desired preset time can be selected in steps of 30 min. using the + /- buttons.
-
Depress the SET button a second time to save the preset time setting in memory.
After that, the green LED will flash to indicate that you are now able to set the power-on time via the
+/- buttons. The remaining power-on time saved in the memory, will be displayed first.
After having set the desired power-on time via the +/- buttons, press the SET button again.
Now, the desired power-on time will be saved in memory.
- After the SET button is depressed, the red LED will flash. The power range setting saved in the
memory, will be displayed first. You can then set the desired power range via the +/- buttons.
The power range is set on the scale 1-16. After this, depress the SET button one more time to make
the heater go into set mode, where the LEDs are continually illuminated to indicate the current status.
- If yellow LED is illuminated, the preset timing is active, and the remaining preset time
is being displayed.
- If the the on/off LED is illuminated red, the heater is switched on, the heating elements are
turned on, and the remaining preset time is being displayed.
- If the on/off LED is illuminated green, the heater is switched on, but the elements are switched
off for the moment - the remaining preset time is being displayed.
-
Once the heater has been set, the set values will remain in memory, and when power is switched on
via the I/O button, the heater will always be warmed up in the same way for the same set period of
time. The preset time, however, will always be zero. If you wish to apply the preset timing feature,
you will always need to activate it separately.
-
If the SET button is not pressed after the setting, the LED will continue flashing for about
1 minute. After this, the heater will automatically return to its normal operating mode and the settings
will be saved in memory.