EN 15821:2010

Multi-firing sauna stoves fired by natural wood logs 

for space heating in residential buildings

Kota Luosto, Luosto VS, Inari, Pallas

Fire safety (initiation, risk to adjacent 

elements)

Pass

- including declared safety

distances to combustible

materials:

Emission of combustible products

Durability

Surface temperature

Release of dangerous substances

Cleanability

Flue gas temperature

Mechanical resistance

Thermal output and

Energy efficiency, as:

- carbon monoxide emission at 13 % O2
- total efficiency
- flue draught

- refuelling loads

- thermal output

(i.e. nominal space heating output)

Back

Side

Ceiling

350 mm

300 mm

1 280 mm

Pass

Pass

NPD

Pass

Pass (0,11 %)

Pass (69 %)

12 Pa

16 kW

8.5 kg

Pass

Pass

392 ˚C 

NAR

VI Oy r

eserves the right to any changes to technical details.

Содержание Kota Inari

Страница 1: ...Made by NARVI Oy Finland GB Kota Luosto Luosto VS Inari Pallas Installation user and maintenance instructions version 1 3...

Страница 2: ...2 GB Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi en...

Страница 3: ...e sauna heater 7 3 1 Preheating 7 3 2 Regulation of the height 7 3 3 Connection with the smoke flue 7 3 4 Installation of a hatch 7 3 5 Installation of a water tank faucet models with a water tank Luo...

Страница 4: ...n or you are under the influence of substances caus ing intoxication Sauna heaters must not be used by underage people Do not leave children in the sauna without supervision A sauna is not meant for d...

Страница 5: ...na heater which will protect the floor moisture barrier and un derfloor heating pipes or cables from the thermal radiation of the sauna heater 2 3 Safety clearances When installing the sauna heater sa...

Страница 6: ...arking When installing a modu lar smoke flue safety clearances stipulated in the installation manual of the smoke flue shall be followed The minimum rec ommended diameter of a modular smoke flue is 12...

Страница 7: ...ft Check that the cover of the unconnected connective flue and cleaning hatch of the smoke pipes is securely in place Seal the unused opening with the supplied cover The sauna heater comes with a shor...

Страница 8: ...any impurities Bigger stones are placed in the bottom of the stone compartment and the rest are piled sparsely so that air can move freely between the stones Flat stones shall be stacked in upright po...

Страница 9: ...awer is closed the power of the sauna heater is at its lowest and the burning time is longer If it soughs too much in the sauna heater reduce the draft To do this close the ash drawer halfway or compl...

Страница 10: ...no glowing coal in the firebox Otherwise fumes may be released in the sauna Carbon monoxide is an odourless and colourless toxic gas If you have not used the sauna heater and smoke flue for a lon ger...

Страница 11: ...nty covers normal family use provided use installation and mainte nance meet the requirements stipulated in the instructions The warranty period starts form the moment that the goods are delivered to...

Страница 12: ...distances to combustible materials Emission of combustible products Durability Surface temperature Release of dangerous substances Cleanability Flue gas temperature Mechanical resistance Thermal outpu...

Отзывы: