Caution of Pendulum Apparatus during the experiment

Caution of Pendulum Apparatus during the experiment

Caution of Pendulum Apparatus during the experiment

Caution of Pendulum Apparatus during the experiment    

 
1. Position of weights 

If  the  weights  are  hooked  like  in  Fig.1,  they  may  cause  errors  in  the  experiment.  When  using 
several weights in the experiment, hook them like in Fig.2 in order to align the center of weights 
(see Fig.1 & 2). 

 
2. Length of Pendulum (thread length) 

Common mistake in measuring the length of pendulum is: measuring the length from the bottom 
vertex  of  a  triangle,  where  weight  is  hooked  (V  shape)  to  the  bottom  surface  of  the  rod  (see 
Fig.3). The correct length of pendulum is from the center of weight to the bottom surface of the 
rod – red line (see Fig. 4). You should use the vertical line distance in Fig.4 as the correct length 
of pendulum. 
 

   

 

          [ Fig.1 ]                              [ Fig. 2 ]                              [ Fig. 3 ]                              [ Fig. 4 ] 
 
 
 

C

C

C

Complete

omplete

omplete

ompleted

d

d

d Apparatus

 Apparatus

 Apparatus

 Apparatus    

 

                         

                               

 

                                      Lever mode                                                                Pendulum mode 
 

Содержание C15-1008-W0

Страница 1: ...much very much for purchasing for purchasing for purchasing for purchasing Lever Lever Lever Lever Pendulum set Pendulum set Pendulum set Pendulum set Read all these instructions before use Read all...

Страница 2: ...as well as energy conversion of potential kinetic energy Safety Precautions Safety Precautions Safety Precautions Safety Precautions r r r read before use ead before use ead before use ead before use...

Страница 3: ...the lever total 24 holes 4 Lever holder 4 Lever holder 4 Lever holder 4 Lever holder Size ca55 50 35mm Weight ca 80g For For For For Pendulum Mode Pendulum Mode Pendulum Mode Pendulum Mode Pendulum Ap...

Страница 4: ...up Pendulum Pendulum Pendulum Pendulum 1 Loose its screw and turn the protractor plate of the pendulum unit to be mounted orthogonally on its rod see step1 2 Tighten the screw on the rod at the orthog...

Страница 5: ...align the center of weights see Fig 1 2 2 Length of Pendulum thread length Common mistake in measuring the length of pendulum is measuring the length from the bottom vertex of a triangle where weight...

Страница 6: ...aratus Storing Pendulum Apparatus Storing Pendulum Apparatus Storing Pendulum Apparatus The pendulum apparatus unit has storage mode such as the lever apparatus 1 Pull the pendulum unit out from the p...

Страница 7: ...lockwise Moment clockwise Let s set weight unit as 1w and set distance unit as 1a In Fig 1 the right side of the lever has a weight at position 4 Its moment of force is Moment clockwise 4a x 1w 4aw Th...

Страница 8: ...ange conditions of experiment such as add weights change length of the string pendulum to 25 30 cm etc and make the experiment again and again to see the different results 3 Result Length cm Weight g...

Отзывы: