INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 18
6. POSSIBLE FAULTS
Due to normal use of the forging machine NARGESA NF70 abnormal situations could arise, we’ll try to
describe some below in order to facilitate the use and repair of it.
These anomalies are reflected in the display of the control.
Fault
Cause
Solution
Thermal of motor
Motor overload mainly due to a material
without the correct temperature
Heat up material up to 800ºC
The rollers do not turn
Fuse F1 at 24 VDC has tripped
Replace F1 fuse with a new one and
check that the white light on the
control box is turned on.
There is a problem with the pedal.
Check the pedal and replace it if
necessary.
The machine does not
initiate properly.
The initiation inductive switch does not
detect it.
Adjust the position of the inductive
switch and check that it works well.
If the problem goes on, please contact our technical assistance in Nargesa
+34 972568085 +34 620446827 [email protected] sat2.nargesa
Содержание NF70
Страница 2: ...Thank you for choosing our machines www nargesa com...
Страница 32: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A 2 A1 List of parts...
Страница 33: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A 3...
Страница 34: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A 4...
Страница 35: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A 5...
Страница 36: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A 6...
Страница 37: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A 7...
Страница 38: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A 8...
Страница 39: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A 9 A2 Electric maps...
Страница 40: ...INSTRUCTIONS BOOK FOR THE END WROUGHT IRON MACHINE NF70 A...