English
14
Electric impact wrench ESR 500
Original operating manual (EN)
Description of the device
1 .......Variable speed switch
2 .......Switch for direction of rotation changing
3 .......Spindle – ½“ square with latch-in pin
4 .......Belt clip
5 .......Fit for belt clip
Table of contents
Description of the device ..................................................................14
General Power Tool Safety Warnings .............................................14
Technical data....................................................................................14
Special Safety Instructions ...............................................................15
Information about noise level and vibrations ..............................15
Intended use .......................................................................................15
How it works ......................................................................................15
Double insulation ..............................................................................15
Belt clip attachement .......................................................................16
Commissioning ..................................................................................16
Instructions for use ............................................................................16
Maintenance and service .................................................................16
Accessories..........................................................................................17
Storage ................................................................................................17
Environmental protection ................................................................17
Warranty .............................................................................................17
Certificate of Conformity ..................................................................17
Technical data
Type
ESR 500
Voltage (V)
230
Frequency (Hz)
50–60
Input (W)
480
NO-load speed (r.p.m.)
0–2 600
Impact rate (i.p.m.)
0–3 000
Max. tightening torque (Nm)
570
Scope of use:
Metric bolts
M10–M22*
Wood screws dia. max. (mm)
8
Drilling dia. max. (mm):
into metal
8
into wood
18
Spindle
½“ square
Spindle chucking
latch-in pin
Weight (kg)
1.52
Safety grade
II /
* Using appropriate torsion bars, bolts of M8 grade and higher can be tightened up
General Power Tool Safety Warnings
WARNING! Read all safety warnings and all instruc-
tions.
Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference!
The term “power tool” in the warnings refers to your mains-operat-
ed (corded) power tool or battery-operated (cordless) power tool.
1) Work area safety
a)
Keep work area clean and well lit.
Cluttered or dark areas
invite accidents.
b)
Do not operate power tools in explosive atmospheres, such
as in the presence of flammable liquids, gases or dust.
Pow‑
er tools create sparks which may ignite the dust or fumes.
c)
Keep children and bystanders away while operating a pow-
er tool.
Distractions can cause you to lose control.
2) Electrical safety
a)
Power tool plugs must match the outlet. Never modify the
plug in any way. Do not use any adapter plugs with earthed
(grounded) power tools.
Unmodified plugs and matching
outlets will reduce risk of electric shock.
b)
Avoid body contact with earthed or grounded surfaces,
such as pipes, radiators, ranges and refrigerators.
There is
an increased risk of electric shock if your body is earthed or
grounded.
c)
Do not expose power tools to rain or wet conditions.
Water
entering a power tool will increase the risk of electric shock.
d)
Do not abuse the cord. Never use the cord for carrying,
pulling or unplugging the power tool. Keep cord away
from heat, oil, sharp edges or moving parts.
Damaged or
entangled cords increase the risk of electric shock.
e)
When operating a power tool outdoors, use an extension
cord suitable for outdoor use.
Use of a cord suitable for out‑
door use reduces the risk of electric shock.
f)
If operating a power tool in a damp location is unavoida-
ble, use a residual current device (RCD) protected supply.
Use of an RCD reduces the risk of electric shock.
3) Personal safety
a)
Stay alert, watch what you are doing and use common
sense when operating a power tool. Do not use a power
Содержание ESR 500
Страница 4: ...4 1 5 2 3 4 4...
Страница 5: ...5...
Страница 23: ...o 23 RCD RCD 3 a 4 a 5 a a 62841 LpA 78 33 A LwA 83 99 A K 3 A ah 18 88 2 K 1 5 2 EN 62841 AD ASR 14...
Страница 34: ......