6.03 USE OF FILLING VALVES:
CAUTION
: Filling valves are very delicate components
that allow you to connect the cylinders to the
compressor. Filling valves must be used with care,
should not be hit, should not be cleaned with solvents or
harmful products and most importantly do not exceed the
pressure for which they are designed.
Normally 225 bar filling valves are attached to a compressor.
To attach the filling valve to the cylinder you must follow these steps:
Make sure that the compressor is turned off and that the filling
valve and the cylinder valve are closed.
Attach the filling valve to the cylinder.
Open completely the cylinder valve.
Open the filling valve.
Start the compressor and fill the cylinder.
At maximum pressure, close the cylinder valve and the filling valve.
Blow-off any residual air between the cylinder and the filling valve and disconnect the cylinder valve.
If you need to use the compressor at a pressure higher than 225 bar Nardi Compressori can provide the
material required to refill at higher pressure with different filling valves, connectors and safety valves with
higher calibration.