background image

 

 

NARDA 
Safety 
Test 
Solutions 

S.r.l. Socio Unico

 

Sales & Support: 

Via Leonardo da Vinci, 21/23 
20090 Segrate (MI) - 

ITALY

 

Tel.: +39 02 2699871 
Fax: +39 02 26998700 

Manufacturing Plant: 

Via Benessea, 29/B 

17035 Cisano sul Neva (SV) 

Tel.: +39 0182 58641 
Fax: +39 0182 586400 

               http://www.narda-sts.it

 

 

 

 

 

SERIAL NUMBER OF THE INSTRUMENT 

You can find the Series Number on the rear panel of the instrument. 
Series Number is in the form: 0000X00000. 
The first four digits and the letter are the Series Number prefix, the last five digits are 
the Series Number suffix. The prefix is the same for identical instruments, it changes 
only when a configuration change is made to the instrument. 
The suffix is different for each instrument.

 

 
Document 6000NEN-90404 –

 

Copyright

 

© NARDA 2007 

 

 

 

 

 
 
 
 
 
 
 
 
 

User’s Manual

 

PMM 6000N 

 

WIDEBAND RF POWER 

AMPLIFIER 

 

9 kHz - 230 MHz / 10 Watts

 

Содержание PMM 6000N

Страница 1: ...ou can find the Series Number on the rear panel of the instrument Series Number is in the form 0000X00000 The first four digits and the letter are the Series Number prefix the last five digits are the...

Страница 2: ...vice Nevertheless even this product will eventually become obsolete When that time comes please remember that electronic equipment must be disposed of in accordance with local regulations This product...

Страница 3: ...6 1 6 2 Installation 2 1 Introduction 2 2 Initial inspection 2 3 Packing and unpacking 2 4 Preparation for use 2 5 Installation check list 2 6 Line voltage selection 2 7 Fuse selection 2 8 Power cable...

Страница 4: ...IV Contents Figures Figure 1 1 1 2 Front Panel Rear Panel Page 1 6 1 6 Tables Table 1 1 Technical Specifications Page 1 2...

Страница 5: ...In case of connection of the device to the power mains make sure before connection that the voltage selected on the voltage switch and the fuses are adequate for the voltage of the actual mains Devic...

Страница 6: ...Via Benessea 29 B 17035 Cisano sul Neva SV ITALY complies with the following European Standards Safety CEI EN 61010 1 2001 EMC EN 61326 1 2007 This product complies with the requirements of the Low V...

Страница 7: ...conditions With an overall gain of 40 dB PMM 6000N has been designed with frequency range and performance according to Basic immunity Standard EN 61000 4 6 IEC 1000 4 6 It is ideally suited for wideb...

Страница 8: ...ut return loss Output impedance Harmonic distortion Spurious Connectors Cooling internal Power supply Dimensions W x H x L Weight Rack mounting Main fuse Protection Metering 9 kHz 230 MHz 10 Watts CW...

Страница 9: ...Typical Performances Typical Gain at Nominal Power dB 30 32 34 36 38 40 42 44 46 48 50 0 001 0 01 0 1 1 10 100 1000 MHz dB Typical Gain at Nominal Power 2 dB 30 32 34 36 38 40 42 44 46 48 50 0 001 0...

Страница 10: ...ion Power output at 1dBc W 0 0 2 0 4 0 6 0 8 0 10 0 12 0 14 0 16 0 18 0 20 0 0 001 0 01 0 1 1 10 100 1000 MHz W Compression at Nominal Power dBc 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 001 0 01 0 1...

Страница 11: ...General Information 1 5 45 40 35 30 25 20 15 10 5 0 0 001 0 01 0 1 1 10 100 1000 MHz dBc 2nd Harmonic at Pn dBc 3rd Harmonic at Pn dBc...

Страница 12: ...Front Panel Legend 1 Input BNC Connector 2 Output N Connector 3 Power Meter 4 Power On Light 5 Alarm Light 1 8 Rear panel Fig 1 2 Rear Panel Legend 1 Mains power switch 2 Fuse receptacle 3 Mains power...

Страница 13: ...ith the Users Manual Notify any damage to the carrier personnel as well as the NARDA Representative 2 4 Preparation for use This is a Safety Class I equipment it is provided with a protective earth te...

Страница 14: ...NARDA for service please complete the service questionnaire enclosed with the Users Manual and attach it to the instrument To minimize the repair time be as specific as possible when describing the f...

Страница 15: ...en internal protection is active current limiter Alarm Indicator Lights when internal temperature exceeds 60 C Panel Meter Indicator Indicates power output Watts into 50 Ohm load 3 5 Placing Equipment...

Страница 16: ...3 2 Operating Instruction This page intentionally left blank...

Страница 17: ...ike to submit to the attention of our service organization is kept in great consideration Moreover we are continuously improving our quality but we know this is a never ending process We would be glad...

Страница 18: ...Suggerimenti Commenti Note Suggestions Comments Note...

Отзывы: