4.4 Additional capabilities of optioned units
Your NS3 can be upgraded at any time to a full featured monitor that
displays additional information as well as stores exposure data. This
upgrade can be accomplished by entering a special code through the
NS3-TS software and enabling the upgrade.
Menu selection screens
Below are the various menu screens and their functions.
Alarm Indication
Allows for altering of the alarm indication between Audible and Vibrate,
Audible only or Vibrate only. Factory default is Audible and Vibrate.
Alarm Threshold
Allows alarm threshold levels to be altered. Alarm 1 can be set from 10%
to 100% and OFF. Alarm 2 can be set from 20% to 200%. Factory
default is Alarm 1 at 50% and Alarm 2 at 200%.
Backlight
Allows setting of display backlight times to OFF, 5 seconds, 10 seconds,
30 seconds, 1 minute and Permanent ON. Factory default is 10
seconds. Longer backlight times result in lower operating time.
Data Log
Sets data logging rate from 4 per second, 1 per second, 5 seconds, 20
seconds or 1 minute. Factory default is 1 sample per second.
Factory Defaults
Resets all monitor functions back to Factory Default values.
F/O Interface
Sets fiber optic interface for communication or remote vibrator operation.
Factory default is the communication setting.
History
Displays maximum, minimum and average readings for the last 6
minutes.
Last Calibration
Displays last calibration dates for sensor and monitor.