3  Preparing the Nardalert S3 for use 

 

 

Nardalert S3 

13 

Items included 

  Check that all the following items have been delivered: 

 

  Carrying Case (2270/90.02) 

  Nardalert S3 Mainframe (2270/01) 

  Silicon Sleeve (2270/90.03), attached to the mainframe 

  Lanyard Clip, non-conductive (2270/90.04) 

  Belt Clip, non-conductive (2270/90.05) 

  Screwdriver Phillips 0 (2270/90.06) 

  User's Guide and CD-ROM with Software NS3-TS (2270/90.07) 

  Car Charger Adapter, USB 5V (2259/92.20) 

  Battery, rechargeable (2259/92.25) 

  Cable, USB2.0 Master/Slave - A/B mini, 0.9m (2260/90.58) 

  Power Supply, USB 5VDC, 100V-240VAC (2259/92.24, packed 

separately) 

  Calibration Certificate, Mainframe 

  Sensor Module with Calibration Certificate (2271/XX, packed 

separately) 

 

 

 

 

USB cable 

Software 

and manuals 

Mainframe and clips 

Space for AC 

power supply 

Battery 

Car charger 

adapter 

Screwdriver 

Space for a detached 

sensor module 

Содержание nardalert S3

Страница 1: ...nardalert S3 Personal Monitor Operating Manual...

Страница 2: ...l understood how it operates and consulted with your company s safety officer Narda Safety Test Solutions GmbH Sandwiesenstrasse 7 72793 Pfullingen Germany Names and logo are registered trademarks of...

Страница 3: ...ent errors 10 Sensor is not installed or operating properly 11 2 4 Dangers from AC mains charger 11 3 Preparing the Nardalert S3 for use 12 3 1 Unpacking 12 Packaging 12 Items included 13 Transport da...

Страница 4: ...Cleaning maintenance repair 28 6 1 Cleaning 28 6 2 Performing calibration 29 6 3 Repair 29 6 4 Verification overview 29 Simplified block diagram 29 Theory of operation 30 Testing RF microwave sensors...

Страница 5: ...oitation of the electromagnetic spectrum We also have various engineering considerations as well as regulatory requirements to use the electromagnetic spectrum wisely Various authorities have long def...

Страница 6: ...forms measurements for human safety purposes particularly in workplace environments where high electric or magnetic field strengths are likely It can also be configured to function as a stand alone ar...

Страница 7: ...gnal words CAUTION WARNING and DANGER Follow all the instructions in order to avoid injuries or death NOTICE Indicates a danger that results in damage to or destruction of the instrument CAUTION Indic...

Страница 8: ...t on 1 2 3 Sequence of instructions Indicates a sequence of instructions that must be carried out in the order given Result Indicates the result of carrying out an instruction e g The instrument start...

Страница 9: ...is Operating Manual Carefully read this entire Operating Manual before you start using the instrument Keep this Operating Manual so that it is available to everyone who uses the instrument and ensure...

Страница 10: ...lectromagnetic fields Very strong electromagnetic fields occur near many radiation sources Observe safety barriers and markings In particular persons with electronic implants must keep away from dange...

Страница 11: ...n upscale indication should be noticed on the display when the radio is transmitting close to the sensor housing Before beginning any RF radiation measurement always inform yourself of the frequencies...

Страница 12: ...to use the Nardalert S3 3 1 Unpacking 3 2 Battery Installation 3 3 Instrument overview 3 4 Connecting the sensor 3 1 Unpacking Packaging The packaging is designed to be re used as long as it has not...

Страница 13: ...Phillips 0 2270 90 06 User s Guide and CD ROM with Software NS3 TS 2270 90 07 Car Charger Adapter USB 5V 2259 92 20 Battery rechargeable 2259 92 25 Cable USB2 0 Master Slave A B mini 0 9m 2260 90 58...

Страница 14: ...brought into a warm room It may be damaged if used Wait until all visible condensation has evaporated from the instrument surface to avoid damaging the instrument Note The instrument is not ready for...

Страница 15: ...r use Nardalert S3 15 3 3 Instrument overview Top Panel Front Panel Rear Panel Power On Off and Enter Key Down Arrow Decrease Up Arrow Increase Alarm LEDs Interchangeable Sensor Alarm LEDs Calibration...

Страница 16: ...rt S3 for use 16 Nardalert S3 Side Panels Mini USB port for charging and data transfer Fiber Optic port for data transfer only Rechargeable and replaceable battery located under door Silicon sleeve fo...

Страница 17: ...If in doubt cycle unit off and then on again to perform connection test If the sensor is defective not installed or failing pre test it will cause the system to not proceed to measurement mode Chargi...

Страница 18: ...nsors under Ordering Information on page 38 as well as in the data sheet of the NS3 These documents can also be downloaded from the Narda website on the internet at www narda sts com Wrong handling of...

Страница 19: ...he NS3 is switched on by depressing and holding the On Off button on the left side of the display The alarm LEDs will illuminate and the vibrator will activate before the splash screen Figure 1 is dis...

Страница 20: ...ges not actual screen Normal operation The operation screen Figure 5 displays the detected fields from the low and high frequency sensors separately to provide information to the wearer about the type...

Страница 21: ...ng properly Note Do not use this function test for verifying calibration This test is only suitable for checking sensors and their connection to the NS3 The readings displayed on the monitor depend on...

Страница 22: ...turn to the Menu Selection Screen without implementing the change 4 If the arrow icon is pointing to the Save and Exit line implement the parameter change save the new parameter in memory and return t...

Страница 23: ...larm 1 can be set from 10 to 100 and OFF Alarm 2 can be set from 20 to 200 Factory default is Alarm 1 at 50 and Alarm 2 at 200 Backlight Allows setting of display backlight times to OFF 5 seconds 10 s...

Страница 24: ...gain to select item to be modified Item is highlighted to confirm selection 3 Tap either the or arrow to cycle through choices 4 Tap the again to select choice Choice is not confirmed until you Save a...

Страница 25: ...ody Some customers prefer to wear the unit mounted to a waist belt while others prefer a lanyard attachment Either method of attachment is acceptable as long as the unit is normally kept close to the...

Страница 26: ...onal or Controlled limits Standards and guidance s normally recommend conservative exposure limits that are both time and spatially averaged and relate to a 100 reading on the NS3 However the NS3 cann...

Страница 27: ...e the monitor to false alarm 5 4 Using the Nardalert S3 as an area monitor The NS3 functions as an effective stand alone area monitoring device It may be operated continuously from the USB supply whil...

Страница 28: ...n damage the Nardalert S3 or the charger Water can damage the charger Do not use solvents to clean the Nardalert S3 and charger As cleaning fluid we recommend the use of lukewarm water to which a drop...

Страница 29: ...sales partner You can find the Narda sales partner responsible for you on the Narda website at www narda sts com All NS3 mainframes need to be returned to their local calibration facility at least onc...

Страница 30: ...d support The NS3 s design utilizes RF shielding and absorbers to isolate it from reflections or scattering produced by the monitor or the human body In general the monitor cannot detect microwave fie...

Страница 31: ...to Category 9 monitoring and control instruments As the manufacturer you can return the device to Narda free of charge for proper environment friendly disposal For more information please contact your...

Страница 32: ...32 Nardalert S3 7 Specifications 7 1 Monitor specifications 7 2 Sensor specifications 7 3 Outline drawing 7 4 Declaration of conformity 7 5 Declaration of origin...

Страница 33: ...erial Full Duplex 57600 baud USB 2 0 mini B jack Serial Full Duplex 57600 baud connector type RP 02 Recommended Calibration Interval 4 Years for Mainframe P N 2270 01 Battery Type Approximate Life RCR...

Страница 34: ...ray Alarm Accuracy 4 5 3 0 dB 100 kHz to 30 GHz 2 5 6 0 dB 30 to 50 GHz 2 5 6 0 dB 50 to 100 GHz Typical Monitor Range a 5 to 200 of Standard or Guidance Immunity at 50 60 Hz 100 kV m CW Overload 3000...

Страница 35: ...7 Specifications Nardalert S3 35 7 4 Declaration of conformity...

Страница 36: ...7 Specifications 36 Nardalert S3 7 5 Declaration of origin Country of origin Germany...

Страница 37: ...7 Specifications Nardalert S3 37...

Страница 38: ...S3 8 Ordering information This chapter contains the information needed for ordering the NS3 together with its sensors and accessories 8 1 Nardalert S3 part numbers 8 2 Sensor part numbers 8 3 Optional...

Страница 39: ...SENSOR MODULE with FCC Sensor Module 2271 101 with IEEE Sensor Module 2271 111 with SC6 Sensor Module 2271 122 with ICNIRP Sensor Module 2271 131 Option Key Nardalert S3 2270 90 01 8 2 Sensor part num...

Страница 40: ...435 Moreland Road Hauppauge NY11788 USA Phone 1 631 231 1700 NardaSTS L3Harris com Narda Safety Test Solutions S r l Via Rimini 22 20142 Milano Italy Phone 39 0258188 1 nardait support L3Harris com Na...

Отзывы: