47
Speci
fi
-
cati
ons
The limit value traces in the standards exhibit
sharp edges. These limit value traces are
simulated in the ESM “RadMan” by means of
equalizer networks. The frequency response
quoted refers to the characteristic of an ideal
equalizer circuit containing only 1st order
decoupled components.
The H-field sensor should not contribute to the
measured signal at frequencies above 1 GHz,
and may at most only contribute the amount
that would accrue if it were specified up to
18 GHz. The H-field sensor may cause a
slight overestimation of the actual exposure
level in narrow frequency ranges above
1 GHz.
Isotropy
Overload limit
Radiation immunity
27 MHz to 500 MHz . . . . . . . . . . . . . +4/-2 dB
CW over standard . . . . . . . . . . . . . . . +20 dB
but not more than
10 kV/m or 26.5 A/m
Pulse < 10 µs
over standard . . . . . . . . . . . . . . . . . . . +40 dB
but not more than
100 kV/m or 256 A/m
at 50/60 Hz . . . . . . . . . . . . . . . . . . . . .1 kV/m
Specifications