Narada Power Source Co., Ltd.
Eos operation manual V5.3
6
Eos-2000
2
2000
1500
1100
349
233
555
566
121
Eos-800A
2
800
600
440
280
186
360.5
372
47
Eos-1000A
2
1000
750
550
339
190
360.5
372
58
Eos-1500A
2
1500
1125
825
496
186
362
374
87
Eos-2000A
2
2000
1500
1100
328.5
363
362
374
115
Eos-3000A
2
3000
2250
1650
496
363
362
374
175
5.Working Principal
The chemical reaction taking place in lead acid battery is as follows:
Pb+PbO
2
+2H
2
SO
4
2PbSO
4
+2H
2
O
Following by-reaction
①
takes place in ordinary lead acid battery:
2H
2
O
2H
2
↑
+O
2
↑
①
This by-reaction makes water loss gradually and pure water need to be added regularly
to keep the battery operate normally.
Eos battery adopts a design of barren-liquor and utilizes AGM (micro porous glass
fiber) separator. Thus there is a path existing between the positive and the negative.
Also special alloy grid is chosen to increase vent hydrogen over-potential gassing on
the negative plate, which prevents generation of hydrogen. Otherwise, the oxygen
generated from positive diffuses through separator to the negative and the oxygen gas
reacts quickly and is recombined into water. The reactions are as follows:
:
2Pb +O
2
2PbO
②
PbO+ H
2
SO
4
PbSO
4
+H
2
O
③
So it is possible to build EOS battery in sealed structure.
Discharge
Charge