background image

Narada

 

Power

 

Source

 

Co.,

 

Ltd.

                                                                                 

313K

 

series

 

12V

 

battery

 

operation

 

manual

 

V1.5

         

18 

After

sales

 

Service

 

/

 

Customer

 

Service

 

Hotline

 

   

Narada

 

Power

 

Source

 

Co.,

 

Ltd.

 

 

 

 

Narada

 

Asia

 

Pacific

 

Pte.

 

Ltd.

 

9F, Building A, No. 50 Zijinghua Road,       

65

 

Ubi

 

Crescent

 

#07

05

 

Hola

 

Centre

 

Hangzhou, China

                                                 

Singapore

 

408559

 

Tel:

 

+86

571

28827007;

 

28827013

  

 

       

Tel:

 

+65

 

6848

 

1191

 

Fax:

 

+86

571

28828290

   

 

 

 

 

 

Fax:

 

+65

 

6749

 

3498

 

Email:

 

[email protected]

                   

 

 

 

Email:

 

[email protected]

  

 

 

Europe:

 

Narada

 

Europe

 

(UK)

 

Limited

 

Spectrum

 

House,

 

Dunstable

 

Road,

   

Redbourn,

 

St.Albans,

 

Herts,

 

AL3

 

7PR

 

Tel:

 

+44

 

(0)845

 

371

 

7095

 

Fax:

 

+44

 

(0)845

 

612

 

2031

 

Email:

 

[email protected]

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

313K

 

se

ri

es

 

12Vb

atte

ry

 

oper

a

ti

on

 

manua

l

 

–N

‐ 

EN

 

(V

er

1

.5

 

A

pr

il,

 

201

3

)

 

 

Su

bj

ect

 

to

 

rev

is

ion

 

w

it

h

out

 

pr

ior

 

no

ti

ce

  

E.

&O

.E

.

 

Содержание 313K Series

Страница 1: ...VALVE REGULATED SEALED LEAD ACID BATTERY High Temperature Applications OPERATION MANUAL Version V1 5 NARADA POWER SOURCE CO LTD 313K Series 12V Battery...

Страница 2: ...ns 5 2 3 Construction 5 2 4 Types and Dimensions 5 Chapter Three Technical characteristic 3 1 Operation environment 6 3 2 Operation conditions 6 3 3 Storage conditions 7 3 4 Battery installation 7 3 5...

Страница 3: ...and heath Please check local laws and regulations to get the validity handle ways or send the equipment to authorized service center z The replacement of battery can only be done by persons who know w...

Страница 4: ...e than 100 rated capacity Residue capacity more than 94 after storage battery 90 days 25 C 2 1 5 Excellence deep cycle performance a patented anti corrosion alloy technology special lead paste formula...

Страница 5: ...ower transformer system Navigation aid signaling system Radio and broadcasting station Emergency lighting system Other standby cyclic system 2 3 Configuration Fig 1 1 Configuration 2 4 Types and Dimen...

Страница 6: ...o EN 50272 2 standard If charge battery with equalization voltage ventilation quantity requirement should be as five times as float charge 3 1 2 Temperature 313K series 12V batteries are high temperat...

Страница 7: ...le as you can 3 4 Battery installation 3 4 1 Open package inspection z Inspection Battery appearance no damage z Check parts complete z Read Installation drawing safety cautions 3 4 2 Installation saf...

Страница 8: ...ttery operation manual V1 5 8 Step 2 Connect batteries with copper bar hex bolts flat washer and spring washer and move protective cover to appropriate place shown as follow drawing Hex bolt Protectiv...

Страница 9: ...manual V1 5 9 Step 3 Connect battery with output connector with hex bolts flat washer and spring washer move protective cover to appropriate place shown as follow drawing Hex bolt Protective cover fo...

Страница 10: ...rallel connection do series connection first then parallel connection In order to ensure better cooling conditions space between batteries should be 10mm at least 4 Recommend connection method 1 24V s...

Страница 11: ...then parallel connection installation diagram 3 48Vsystem 2 layers 8 blocks series first then parallel connection installation diagram 4 48Vsystem 2 layers 8 blocks series first then parallel connecti...

Страница 12: ...ust on surface of battery pole before and after installation 6 Electrify battery bank after measure total voltage correctly 3 5 Charge 3 5 1 Float charge parameter Float voltage 2 24V cell 35 Charge c...

Страница 13: ...f temperature is below 5 Setting charge capacity 110 120 of discharge capacity 3 5 4 Lower temperature below 5 longer charge time It is easy over charge at high temperature Charge at recommended tempe...

Страница 14: ...stant current discharge data A 35 12HTB 100A 5 min 10 min 15 min 30 min 1hr 2hr 3hr 5hr 8hr 10hr 12hr 20hr 24hr 1 60V 288 209 168 111 69 5 41 3 30 9 19 5 13 1 10 7 9 11 5 71 4 81 1 67V 287 208 168 110...

Страница 15: ...ster 2 Charger and discharger special for storage battery portable 4 2 Maintenance In order to assure service life the batteries should be correctly inspected and maintained The maintenance methods of...

Страница 16: ...0 89C10 1 78 I10 1 80 3HR C3 0 75C10 2 5 I10 1 80 1HR C1 0 55C10 5 5 I10 1 75 Standard Capacity temperature is base on 25 Convert the testing capacity Cr to standard capacity Ce according to formula i...

Страница 17: ...and crack Replace reverse polarity connection and crack battery 4 There are white crystal in terminal or valve ports If it is false leaking clean white crystals with a soft cloth dipped with soapy wat...

Страница 18: ...e Hangzhou China Singapore 408559 Tel 86 571 28827007 28827013 Tel 65 6848 1191 Fax 86 571 28828290 Fax 65 6749 3498 Email intl narada biz Email sales narada com sg Europe Narada Europe UK Limited Spe...