The appliance is equipped with two catalytic tiles which are designed to fi lter out harmful gases and limit
carbon monoxide output. It is likely that with the appliance in operation, the catalytic tiles will actually scrub
the carbone monoxide normally found in the room and reduce it to a lower level. The tiles must not be altered
or removed. Do not operate the appliances when using products such as paint, paint thinner, adhesives, etc.
These products will permanently affect the catalytic tiles’ ability to scrub the air.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
2.4 RATING PLATE INFORMATION
SAMPLE
For rating plate location, see “INSTALLATION OVERVIEW”
section.
This illustration is for reference only. Refer to the rating
plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance
at all times. It must not be removed.
WHVF24
CWHVF24N
L
E
D
O
M
E
N
A
P
O
R
P
L
E
D
O
M
S
A
G
L
A
R
U
T
A
N
*0-2000FT
ALTITUDE
*0-2000FT
9,000
BTU/HR
INPUT
9,000BTU/HR
BQ902C01
CONTROL
BQ902C01
BENAN 20310 (NG)
PILOT
MANIFOLD PRESSURE: 3.5”
WATER COLUMN (NG)
MIN. SUPPLY PRESSURE: 4.5”
WATER COLUMN (NG)
MAX. SUPPLY PRESSURE: 7”
WATER COLUMN (NG)
MANIFOLD PRESSURE: 10”
WATER COLUMN (LP)
MIN. SUPPLY PRESSURE: 11”
WATER COLUMN (LP)
MAX. SUPPLY PRESSURE: 13”
WATER COLUMN (LP)
NOT FOR USE WITH SOLID FUEL
WARNING:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE FLAME. DO NOT USE
ACCESSORIES NOT APPROVED FOR USE WITH THIS APPLIANCE.
APPLY LOOSE MATERIAL PER INSTRUCTIONS MANUAL. DO NOT
APPLY EXTRA MATERIAL OR MATERIAL NOT SUPPLIED WITH THE
APPLIANCE. IMPROPER INSTALLATION, ADJUSTMENT, ALTERNATION,
SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER’S
INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED
INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL
(FROM APPLIANCE):
MANTEL 20”
FLOOR 10”
SIDES
7”
WHVF24
SERIAL NUMBER
*ABOVE 2,000FT, CONSULT LOCAL AUTHORITY HAVING JURISDICTION.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
BENAN 20310 (LP)
WHVF24
CWHVF24P
CERTIFIED FOR / CERTIFIEE
POUR CANADA / USA
REFERENCE # 161746
CERTIFIED UNDER: ANSI Z21.11A-2010 UNVENTED ROOM HEATER
THIS APPLIANCE SHALL NOT BE INSTALLED IN BATHROOM, AND IS
INTENDED FOR SUPPLEMENTAL HEATING. THIS APPLIANCE MAY BE
INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED,
MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY
LOCAL CODES. THIS APPLIANCE IS ONLY FOR
USE WITH THE TYPE OF GAS INDICATED ON
THE RATING PLATE. THIS APPLIANCE IS NOT
FIELD CONVERTIBLE FOR USE WITH OTHER
GASES. THIS IS A GAS-FIRED UNVENTED
ROOM HEATER THAT REQUIRES ADEQUATE
COMBUSTION AND VENTILATION AIR.
W415-1158 / A / 11.19.13
7