Adjust the pilot screw to provide properly sized fl ame.  Turn in a 
clockwise direction to reduce the gas fl ow.

Inlet pressure can be checked by turning screw (A) counter-
clockwise until loosened and then placing pressure gauge tubing 
over the test point. Gauge should read 7” (minimum 4.5”) water 
column for natural gas or 13” (11” minimum) water column 
for propane. Check the inlet pressure while the main burner is 
operating on “HI”.

Outlet pressure can be checked the same as above using screw 
(B). Gauge should read 3.5” water column for natural gas or 10” 
water column for propane. Check that main burner is operating.

AFTER TAKING PRESSURE READINGS, TIGHTEN SCREWS 
FIRMLY TO SEAL. DO NOT OVER TORQUE.

LEAK TEST.

  Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada   •     1(866)820-8686    •    www.napoleon.com

ADJUSTMENTS

VENTURI ADJUSTMENT

Air shutter adjustment must be done by a qualifi ed 

installer!

Air shutters have been factory set open according to the chart 
below:  

Closing the air shutter will cause a more yellow fl ame, but can 

lead to carboning. Opening the air shutter will cause a more 
blue fl ame, but can cause fl ame lifting from the burner ports.  
The fl ame may not appear yellow immediately; allow 15 to 30 
minutes for the fi nal fl ame colour to be established.

Adjustment may be required depending on fuel type, vent con-
fi guration and altitude.

FLAME CHARACTERISTICS

PRESSURE ADJUSTMENT

A

B

PILOT SCREW

P

NG

C/GDI3 / E

3/16”

1/16”

C/GDIX3

1/4”

1/8”

VENTURI

AIR SHUTTER 
OPENING

ORIFICE

It’s important to periodically perform a visual check of the pilot and burner 
fl ames. Compare them to the illustrations below.

PILOT 

BURNER

FLAME MUST ENVELOP 
UPPER 3/8” TO 1/2” OF
FLAME SENSOR 

FLAME

SENSOR

ELECTRODE

W415-1918 / B / 01.09.20

P

I

PILOT

N

O

L

O

T

H I

LO

FF O

A

B

PILOT SCREW

ELECTRONIC

(C/GDI3E / 

C/GDIX3)

MILLIVOLT

(C/GDI3)

HOOD

PILOT

ORIFICE

ELECTRONIC

(C/GDI3E / 

C/GDIX3)

MILLIVOLT

(C/GDI3)

OLKI3 Log Set

(C/GDI3 / E)

OLKIX3 Log Set

(C/GDIX3)

Maximum Input Ratings

P

NG

C/GDI3 / E

24,500

C/GDIX3

30,000

Содержание W175-0689

Страница 1: ...use only parts specifically ap proved with this appliance may result in property damage or personal injury CAUTION Before proceeding with the conversion shut off the gas supply first and then disconnect the electrical power 1 Remove the door logs and panels from the ap pliance see the finishing section of your installa tion manual 2 Remove the 7 screws that secure the log cover in place Lift the cov...

Страница 2: ...hutters have been factory set open according to the chart below Closing the air shutter will cause a more yellow flame but can lead to carboning Opening the air shutter will cause a more blue flame but can cause flame lifting from the burner ports The flame may not appear yellow immediately allow 15 to 30 minutes for the final flame colour to be established Adjustment may be required depending on ...

Страница 3: ...ant d effecteur la conversion vous devez couper l alimentation en gaz avant de couper l alimentation électrique 1 Retirez la porte les bûches et les panneaux de l appareil voir la section finitions dans votre manuel d installations 2 Retirez les 7 vis servant à fixer la couverture de bûche en place Soulevez la couverture puis la retirez Fig 1 3 Retirez les 2 vis servant à fixer le brûleur tubulair...

Страница 4: ...flamme est jaune et aura tendance à causer des dépôts de carbone Plus le volet est ouvert plus la flamme est bleue et plus elle a tendance à se détacher des orifices du brûleur La flamme peut ne pas être jaune immédiatement allouez de 15 à 30 minutes pour que la couleur finale de la flamme se stabilise D autres réglages peuvent être nécessaires selon le type de gaz utilisé la configuration d évacu...

Отзывы: