WARNING

• 

If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, 
personal injury or death.

• 

Ensure the appliance, safety barrier and glass are completely cool before starting installation.

• 

To avoid danger of suffocation keep the packaging bag away from babies and children. Do not use in cribs, bed, 
carriages, or play pens. This bag is not a toy. Knot before throwing away.

Installer

: Leave this leafl et with the appliance. Consumer: Retain this leafl et for future reference.

Caution

: A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be 

installed. This barrier is not designed for prolonged contact.

Included in this kit:

2 x fl exible duct 

- 5 ft (alum.)

This kit moves the warm air from your fi replace enclosure to be expelled into the room. Where duct lengths are greater than 
5 feet, it is recommended that the duct be insulated. 

We recommend installing the grills and vent boots in the same 

room as the appliance.

We recommend installing the Universal Heat Management kit during the installation of the appliance 

BEFORE

 gas is 

installed.

IMPORTANT

2 x collar assembly

2 x vent boot

2 x grill

You will need:

Drill

Phillips Bit

Hex Bit

Gloves

Содержание UHM

Страница 1: ...eaflet with the appliance Consumer Retain this leaflet for future reference Caution A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall...

Страница 2: ...note Minimum 1 25mm clearance all around the exible duct Minimum 3 76mm clearance to enclosure top 84 213cm minimum recess install Minimum 3 4 76mm top clearance to nishing material required when ven...

Страница 3: ...el KNOCKOUT 1 Remove knockouts x2 from the top of the appliance Discard 2 Remove insulation quantity shape and size varies by model from the top of the appliance Discard 3 Remove cover quantity shape...

Страница 4: ...ot supplied the vent boot to framing members while maintaining the 3 76mm minimum clearance from the enclosure top Ensure to maintain minimum 3 4 clearance to finishing material above the vent boots w...

Страница 5: ...embly MUST be installed during appliance operation Failure to maintain clearances or follow the installation instrucitons provided in your manual could result in serious injury death or property damag...

Страница 6: ...RTISSEMENT Si ces instructions ne sont pas suivies la lettre un incendie ou une explosion pourraient s ensuivre causant des dommages mat riels des blessures corporelles ou des pertes de vie Assurez vo...

Страница 7: ...minimum 3 4 76mm au dessus jusqu au mat riau de nition l adaptateur d vacuation est requis lors de le monter horizontalement R f rez le manuel d installation de votre appareil pour l hauteur de l enc...

Страница 8: ...ieures x2 au dessus de la chambre de combustion L ensemble du syst me gestion thermique universelle DOIT tre installer compl tement IMPORTANT INSULATION quantity shape and size varies by model COVER q...

Страница 9: ...m 3 4 au dessus jusqu au mat riau de finition de les adaptateurs d vacuation lors de les mont s horizontalement R p tez pour l autre adapteur d vacuation 9 Faites passer le conduit flexible entre les...

Страница 10: ...tion de l appareil Ne respectez pas les d gagements ou l incapacit suivres les instructions fournies dans votre manuel peuvent entra ner de grave blessures des pertes de vie ou des dommages mat riels...

Отзывы: