TROUBLE SHOOTING GUIDE

BEFORE

 

ATTEMPTING

 

TO

 

TROUBLESHOOT

PURGE

 

YOUR

 

UNIT

 

AND

 

INITIALLY

 

LIGHT

 

THE

 

IGNITOR

 

AND

 

THE

 

MAIN

 

BURNER

 

WITH

 

THE

 

GLASS

 

DOOR

 

OPEN

.

SYMPTOM

PROBLEM

TEST SOLUTION

Electrode sparks, burner 
ignites,  electrode 
continues to spark for 
complete 7 seconds, 
burner shuts down.

Hot and neutral wires are reversed 
at control module.

Sensor / 

fl

 ame not connecting

- Connect the hot wire to the black wire.  Connect the neutral wire to  
  the white wire.

- Raise electrode / sensor up into 

fl

 ame.

Main burner 

fl

 ame is a 

blue, lazy, transparent 

fl

 ame.

Blockage in vent.

- Remove blockage. In extremely cold conditions, ice buildup may occur  
  on the terminal and should be removed as required.

Flame length 
consistently too large 
or too small.  Carboning 
occurs.

Unit is over-

fi

 red or under-

fi

 red.

- Check pressure readings
- Outlet pressure can be checked by removing cap (A) and replacing  
  it with a 1/8” NPT barb 

fi

 tting.  Next, place pressure gauge tubing  

 over the 

fi

 tting.  Gauge should read 3.5” W.C. for natural gas or  

  10.0” W.C. for propane.  AFTER TAKING PRESSURE READINGS,  
  BE SURE TO REPLACE CAP TO RESEAL. DO NOT OVER-TORQUE.
- Leak test with a soap and water solution.

Carbon is being 
deposited on glass, logs 
or combustion chamber 
surfaces.

Air shutter has become blocked.

- Ensure air shutter opening is free of lint or other obstructions.

Flame is impinging on the 
combustion chamber.

- Open air shutter to increase the primary air.
- Check the input rate: check the manifold pressure and ori

fi

 ce size as  

 speci

fi

 ed by the rating plate values.

- Check that the door gasketing is not broken or missing and that the  
  seal is tight.
- Check that both 3” and 5” vent liners are free of holes and well   
  sealed at all joints.
- Check that the minimum rise per foot has been adhered to for any           
 horizontal venting.

White / grey 

fi

 lm forms.

Sulphur from fuel is being 
deposited on glass, logs or 
combustion chamber surfaces.

- Clean the glass with a gas 

fi

 replace glass cleaner.  

DO NOT CLEAN  

  GLASS WHEN HOT.

   If deposits are not cleaned off regularly, the  

  glass may become permanently marked.

Exhaust fumes smelled in 
room, headaches.

Fireplace is spilling.

- Check door seal.
- Check pressure relief device.
- Check for chimney blockage.
- Ensure that the paint curing process is complete.

No gas to the main 
burner; switch is on.

Switch is defective.

- Connect a jumper wire across the wall switch terminals; if main   
  burner lights, replace switch / thermostat.

Burner ori

fi

 ce is blocked.

- Remove stoppage in ori

fi

 ce.

Control valve faulty.

- Replace.

Faulty valve.

- Replace.

Burner will not light, 
ignitor sparks.

No gas at the burner.

- Check that the manual valve is turned on.
- Replace the valve.

Out of propane gas.

- Fill the tank.

Ignitor 
will 
not 
spark.

No spark at ignitor.

- Check the power source. (ie. fuse, circuit breaker)
- Check that the wire is connected to both the ignitor and the control  
 module.
- Check that the spark is not jumping to ignitor cover.
- Replace the wire if the wire insulation is broken or frayed.
- Replace the electrode if the ceramic insulator is cracked or broken.

Spark gap is incorrect.

- Spark gap should be 0.125” (1/8” approx.) from the electrode tip to the  
 sensor tip.

Remote wall switch is in 
“OFF” position; burner 
comes on.

Wall switch is mounted upside 
down.

- Reverse.

Remote wall switch is grounding.

- Replace.

Remote wall switch wire is 
grounding.

- Check for ground (short); repair ground or replace wire.

Faulty wire.

- Replace.

Содержание TORCH GT8P

Страница 1: ...y appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot re...

Страница 2: ...erials gasoline and other flammable vapours and liquids Under no circumstances should this fireplace be modified This fireplace must not be connected to a chimney flue pipe serving a separate solid fu...

Страница 3: ...ents and wearable parts such as blowers gas valves thermal switch switches wiring remote controls ignitor gasketing and pilot assembly are covered and NAPOLEON will provide replacement parts free of c...

Страница 4: ...on carpeting vinyl tile or other combustible material other than wood flooring the fireplace shall be installed on a metal or wood panel extending the full width and depth GENERAL INSTRUCTIONS GENERA...

Страница 5: ...als on the inner exhaust flue only the outer air intake joints must be sealed using a red high temperature silicone RTV This same sealant may be used on both the inner exhaust and outer intake vent pi...

Страница 6: ...ated with the insulation wrapped in a protective sleeve to minimize condensation Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed Use firesto...

Страница 7: ...24 2a Horizontal run if vent run includes vertical rise 4 7 FT 2b Vertical run Immediately off the fireplace if 7 FT maximum horizontal run is required 18 7 FT 2b 2c FIGURE 2a 4 MIN 24 MAX 8 18 MAXIMU...

Страница 8: ...excluding fireplace and air terminal connections N A 2 Rise per foot recommended 1 4 N A Rise per foot allowable 0 N A Vertical run when not venting horizontally 24 19 1 2 FT 3a 3c Horizontal run 4 5...

Страница 9: ...9 W415 0619 B 03 03 08 O O B B G A F C H H L K J M MINIMUM AIR TERNMINAL LOCATION CLEARANCES N D E O FIGURE 4...

Страница 10: ...g to cut them Use a plumb bob to line up the center of the openings Do not fill this space with any type of material A vent pipe shield will prevent any materials such as insulation from filling up th...

Страница 11: ...e joints may be sealed using high temperature sealant W573 0002 not supplied or the high temperature sealant W573 0007 Mill Pac not supplied However the high temperature sealant W573 0007 Mill Pac not...

Страница 12: ...ed Conversion Kits The mobile home appliance is field convertible between Natural Gas NG and Propane LP To convert from one gas to another consult your Napoleon dealer distributor FIGURE 14 STORM COLL...

Страница 13: ...18 WARNING RISK OF ELECTRIC SHOCK Control and valve operate with 110v 1 2 3 4 YELLOW BROWN W H I T E P U R P L E B L A C K IGNITOR WIRE IGNITOR GAS VALVE SWITCH CONTROL MODULE GROUND 110v POWER SUPPL...

Страница 14: ...s installed Frame to local building codes To install the fireplace face flush with the finished surface position the framework to accommodate the thickness of the finished surface Use 4 flat head scre...

Страница 15: ...from the slots in the door frame to release the top of the door Then pivot forward until the top edge of the door clears the front of the fireplace Next gripping the sides of the door lift the door ou...

Страница 16: ...7 Once the frame is perfectly square and the control door will close without rubbing against the sides of the frame tighten all screws 8 Open the control door 9 Insert the door stop chain into the re...

Страница 17: ...res into the clips at both sides and the bottom of the frame Use the extra clips provided to retain any loose wires 7 Re attach frame onto unit 8 Remove the control panel by removing the 2 screws secu...

Страница 18: ...2 Turn off all electrical power to the fireplace if service is to be preformed 3 Turn manual shut off valve clockwise to off Do not force TO TURN OFF GAS CERTIFIED UNDER CSA 2 22 2007 ANSI 21 50 2007...

Страница 19: ...pressure FIGURE 34 FIGURE 33 TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause imprope...

Страница 20: ...LACE 2 INSTALLATION DATE OF FIREPLACE 3 PART NUMBER 4 DESCRIPTION OF PART 5 FINISH FOR WARRANTY REPLACEMENT PARTS A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM IDENTIFIES IT...

Страница 21: ...issing and that the seal is tight Check that both 3 and 5 vent liners are free of holes and well sealed at all joints Check that the minimum rise per foot has been adhered to for any horizontal ventin...

Страница 22: ...22 W415 0619 B 03 03 08 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS...

Отзывы: