background image

10

SAFETY CHECK

Check for leak

Your patio heater has been checked at all factory 
connections for leakage. To check the connections 
at the tube/regulator/cylinder.
1) Make leakage solution by mixing 1 part liquid 
    dish soap and 3 parts water.
2) Spoon several drops (or use squirt bottle) of the 
    solution onto the tube/regulator/cylinder 
    connections.
3) Inspect the connections and look for bubbles.
4) If no bubble appears, the connection is safe.
5) If bubble appears, there is leak; loosen and 
    re-tighten this connection. If still leak, please 
    call customer service: 1-888-831-1899.

Disconnected cylinder when storage or 
transportation

1) Turn the knob at “OFF” position.
2) Open the access door, turn clockwise to 
    disconnect cylinder from regulator.

Regulator & cylinder 
connection

Tube & regulator 
connection

Содержание Tabletop Patio Heater

Страница 1: ...way from the appliance and immediately call your gas supplier or fire department Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP...

Страница 2: ...r maintenance can cause injury death or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment PRECAUTIONS SPECIFICATION...

Страница 3: ...n and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necess...

Страница 4: ...pliance The cylinder be disconnected when the appli ance is not is use Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from the appliance A cylinder mus...

Страница 5: ...CLUDED Adjustable open end wrench Philips screwdriver Estimated time for assembly 15 minutes PREPARATION Before beginning assembly of product make sure all parts are present If any part is missing or...

Страница 6: ...The fastenersused comply with ANSI BL 1 1 Base 1 Housing 1 Burner Column 2 Emitter Screen Shield 1 Emitter Screen 1 Reflector Dome 1 Dome Cap 1 Decorative Dome Cap Nut 1 2 3 4 5 6 7 8 9 10 11 12 13 3...

Страница 7: ...T Step 2 Insert the three clamps of the burner column 3 into the three spring pieces of the housing 2 per the picture and screw over Make sure the clamp and the spring piece fit together Step 1 Attach...

Страница 8: ...een must line to the control knob Step 4 Attach reflector dome 6 to emitter screen 5 using six 6mm washers 12 and three M6 nuts 11 Then attach dome cap 7 and decorative dome cap nut 8 to reflector dom...

Страница 9: ...to burner column 3 using four M4 x 8 bolts 9 Step 6 Open the access door Open up the gas bottle cover Attach it to the regulator Aim at the screw thread Turn counter clockwise and tighten 4 4 4 4 3 3...

Страница 10: ...ution onto the tube regulator cylinder connections 3 Inspect the connections and look for bubbles 4 If no bubble appears the connection is safe 5 If bubble appears there is leak loosen and re tighten...

Страница 11: ...dissipate before attempting to light heater If after 1 minute you are unable to light burner wait 5 minutes and allow flammable vapors to dissipate before attempting to light heater 1 Turn the control...

Страница 12: ...s will light the pilot If needed keep depressing and turning control knob counter clockwise until the pilot lights You will hear 1 clicking noise 5 Once the pilot is lit keep the control knob depresse...

Страница 13: ...minutes before attempting to relight pilot 3 Repeat steps beginning with step 4 of the lighting instruction above Shut down instructions 1 Push in and turn control knob clockwise to OFF position 2 Tu...

Страница 14: ...for the heating of outdoor patios decks spas pools and open working areas Always make sure that adequate fresh air ventilation is provided Follow the spacing tolerances shown in Figure 1 at all times...

Страница 15: ...ed to water in any way do NOT try to use it It must be replaced Keep the appliance area free and clean from combustible materials gasoline or other flammable vapors an liquids Visually check buner fla...

Страница 16: ...prevent build up in air passages STORAGE Between uses During periods of extended inactivity or when transporting Turn the control knob to OFF position Disconnect the cylinder from the regulator by tur...

Страница 17: ...t will not stay on Debris around pilot Clean dirty area Tighten connection Thermocouple Contact customer service Gas leak in line Check connections Lack of fuel pressure Fuel tank is near empty Pressu...

Страница 18: ...ective from the date of purchase as shown in the purchaser s receipt This warranty is valid for the original consumer purchaser only and excludes industrial commercial or business use of the product p...

Страница 19: ...avec base plus petite 4 Acier inoxydable avec base plus petite 8 Base en aluminium coul 9 Base en fonte forme du trou de ventilation 1 Rond 2 Losange 3 Rectangulaire r flecteur 1 R flecteur 1 pi ce 2...