ONE-YEAR LIMITED WARRANTY

The appliance has been manufactured under the highest standards of quality and workmanship. We

warrant to the original consumer purchaser that all aspects of this product will be free of defects in

material and workmanship for one (1) year from the date of purchase. A replacement for any defective

part will be supplied free of charge for installation by the consumer. Defects or damage caused by the

use of other than genuine parts are not covered by this warranty. This warranty shall be effective from

the date of purchase as shown in the purchaser’s receipt. 

This warranty is valid for the original consumer purchaser only and excludes industrial, commercial or

business use of the product, product damage due to shipment or failure which results from alteration,

product abuse, or product misuse, whether performed by a contractor, service company, or consumer.

We will not be responsible for labor charges and/or damage incurred in installation, repair or replace-

ment, nor for incidental or consequential damage.

NAC Customer Care

214 Bayview Drive

Barrie, ON

Canada, L4N 4Y8

1-866-820-8686

[email protected]

This warranty may give you specific legal rights that vary by state or province.

Содержание PTH40PGM

Страница 1: ...r Use Only CAUTION Installer Leave the instruction manual with the user for future use Consumer Please keep this manual for future reference Read the instructions before use This appliance must be installed in accordance with such regulations as are in force An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance Model PTH40PGM Standard ANS Z83 26 20...

Страница 2: ...SA Height Overall 2 28m 89 8 Reflector Diameter 85cm 33 5 Rated Heat Input 40000 BTU HR G P L l e u F Gas Supply 20Lb 9kg LP Gas cylinder Manifold Pressure 11 0 W C Injector Size diameter 1 95mm Safety Features Flame failure device anti tilt switch pilot Gas Supply Pressure Max 250PSI Min 5PSI 2 The bill of sale or copy will be required together with the serial and model numbers when making any wa...

Страница 3: ...or in areas where the hose will not be subject to accidental damage Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary ...

Страница 4: ...ance A cylinder must be stored outdoors in a well ventilated area out of the reach of children A disconnected cylinder must have dust caps tightly installed and must not be stored in a build ing garage or any other enclosed area The pressure regulator and hose assembly sup plied with the appliance must be used replace ment pressure regulators and hose assemblies must be those specified by the appl...

Страница 5: ...r Estimated time for assembly 30 minutes Before beginning assembly of product make sure all parts are present If any part is missing or damaged do not attempt to assemble the product Contact customer service for replacement parts Perform a leak test with a soapy solution 1 To check gas connections 2 After connecting a new cylinder 3 Upon re assembly after disassembly TOOLS NEEDED NOT INCLUDED 5 ...

Страница 6: ...3 M6x14 Bolts 15 M6 Nuts 18 6mm Washers 12 M6x10 Screws 3 M6x70 Double Pointed Bolts 5 M4x8 Bolts 6 M5x8 Bolts 1 Cylinder Chain 1 Center Reflector Cap 5 Reflector Caps 1 Burner Assembly 1 Upper Pole 1 Low Pole 1 Desk surface 1 Pole supporting board 1 Gas Hose Regulator 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 ...

Страница 7: ...p 2 ASSEMBLY 5 16 17 18 8 6 Hardware Used Hardware Used 5mm washer X 6 M5 X 8 bolt X 6 M6 X 14 bolt X 3 Step 1 Step 2 Insert low pole 5 into the pole supporting board 8 fix it with 6 pcs 5mm washer 17 and 6 pcs M5 8 bolt 16 Put the desk surface 6 on the low pole 5 fix it with 3 pcs M6 14 bolt 18 5 16 17 18 ...

Страница 8: ...ardware Used 4mm washer X 5 M4 X 8 bolt X 5 Step 3 Step 4 4 3 4 5 14 Step 4 Connect the upper pole 4 on the low pole 5 fix it with 3pcs M4 6 bolt 14 Insert the burner assembly 3 in the upper pole 4 fix it with 5pcs 4mm washer 15 and 5pcs M4 8 bolt 13 13 15 ...

Страница 9: ...Bolts x 3 6mm Washer x 6 Hardware Used Step 5 Step 6 Step 6 Attach the center reflector cap 1 on the top of the four reflector cap 2 by twelve sets of M6x10 screw 11 6mm washer 10 and M6 nut 9 Install reflector assembly 2 fix it with 3pcs M6 70 double pointed bolt 12 6pcs 6mm washer 10 and 3 pcs M6 nut 9 1 2 11 9 10 2 12 9 10 ...

Страница 10: ...10 ASSEMBLY Step 7 Open the door Put cylinder into the big hole on bottom panel and lock the cylinder chain Step 7 Tighten ...

Страница 11: ...e solution by mixing 1part liquid dish soap and 3 parts water 2 Spoon or brush several drops or use squirt bottle of the solution onto hose connection regulator cylinder connection 3 Turn on gas cylinder valve Inspect the connections and look for bubbles 4 If no bubbles appear the connection is safe 5 If bubbles appear there is a leak Loosen and re tighten this connection If there is still a leak ...

Страница 12: ...ove igniter button by turning counter clockwise Install AAA battery with positive terminal up as indicated in diagram Replace igniter button IGNITER BATTERY INSTALLATION Ignition button Control knob AAA battery Ignition button Replace Battery ...

Страница 13: ...r lighting operations will cause serious injury and explosion Your heater was designed and approved for OUTDOOR USE ONLY DO NOT use it inside a building or any other enclosed area Make sure surrounding areas are free of combustible materials gasoline and other flammable vapors or liquids Ensure that there is no obstruction to air ventilation Be sure all gas connections are tight and there are no l...

Страница 14: ...e pilot lights 4 Once the pilot is lit release the igniter button and continue to depress the control knob for 30 seconds 5 After depressing the control knob for 30 seconds release the control knob and turn it counter clockwise to the LOW or HIGH position Note If the pilot light will not ignite turn the control knob to the off position and fully close the propane tank valve Wait 5 minutes and then...

Страница 15: ...t five 5 minutes before attempting to relight pilot 3 Repeat steps beginning with step 2 of the lighting instruction above Shut down instructions 1 Push in and turn control knob clockwise to OFF position 2 Turn LP cylinder gas valve clockwise to OFF position when heater is not in use Note After use some discoloration of the emitter screen is normal The Event of Gas Leakage 1 Turn the control knob ...

Страница 16: ...er is primarily used for the heating of outdoor patios decks spas pools and open working areas Always make sure that adequate fresh air ventilation is provided Follow the spacing tolerances shown in Figure 1 at all times This heater must be placed on level firm ground Never operate in an explosive atmosphere Keep away from areas where gasoline or other flammable liquids or vapors are stored or use...

Страница 17: ...and pilot assembly dry at all times If the gas control is exposed to water in any way do NOT try to use it It must be replaced Keep the appliance area free and clean from combustible materials gasoline and other flammable vapors and liquids not obstructing the flow of combustion and ventilation air keeping the ventilation opening s of the cylinder enclosure free and clear from debris Gas odor with...

Страница 18: ... heavy duty pipe cleaner Compressed air may help clear away smaller particles Carbon deposits may create a fire hazard Clean dome and engine with warm soapy water if any carbon deposits develop STORAGE Between uses During periods of extended inactivity or when transporting Turn the control knob to OFF position Disconnect the regulator from the LP Cylinder by turning counter clockwise and move to a...

Страница 19: ...ot will not stay on Debris around pilot Clean dirty area Tighten connection Thermocouple Contact customer service Gas leak in line Check connections Lack of fuel pressure Fuel tank is near empty Pressure is low Fuel tank is near empty Control valve not ON Turn valve to ON Thermocouple broken Contact customer service Contact customer service Pilot light assembly bent or not in correct location Burn...

Страница 20: ...all be effective from the date of purchase as shown in the purchaser s receipt This warranty is valid for the original consumer purchaser only and excludes industrial commercial or business use of the product product damage due to shipment or failure which results from alteration product abuse or product misuse whether performed by a contractor service company or consumer We will not be responsibl...