![Napoleon NZ6000-1 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/napoleon/nz6000-1/nz6000-1_installation-and-operating-instructions-manual_707007029.webp)
W415-1501 / 05.15.15
29
EN
6.8 FIREBRICK AND BAFFLE INSTALLATION
OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE
TEMPERATURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE
SURROUNDING ENCLOSURE.
Place the side and rear firebricks against the wall.
For easy start up open the by-pass damper.
Place the by-pass damper
on the supports at the rear
and sides of the firebox.
SIDE VIEW
BY-PASS IN “CLOSED” POSITION
SIDE VIEW
BY-PASS IN “OPEN” POSITION
The by-pass damper should be in the "OPEN" position when using the spark screen, during start-up, when
loading fuel and in warmer months where less heat is preferred.
The by-pass damper should be in the "CLOSED" position when the doors are closed and proper chimney
draw is established.