42
W415-0695 / A / 06.07.10
10.4 AIR CONTROL ROD ACCESS
10.4.1
Remove the glass door.
10.4.2
Remove the logs.
10.4.3
Remove the air de
fl
ector / light housing
(It is not
necessary to disconnect the wires. The assembly
can lay along the right side of the
fi
rebox).
10.4.4
The air control rod can now be adjusted. Pushing
the rod towards the back will open the air shutter
(larger hole, larger opening), pulling the rod towards
the front will close the shutter (smaller hole, smaller
opening).
10.3 FLAME CHARACTERISTICS
It’s important to periodically perform a visual check of the pilot and
burner
fl
ames. Compare them to the illustrations provided. If any
fl
ames
appear abnormal call a service person.
54.2
3/8” - 1/2”
FLAME MUST
ENVELOPE UPPER
3/8" TO 1/2" OF
THERMOCOUPLE &
THERMOPILE