6
W415-1033 / A / 10.12.11
2.4 GENERAL
INFORMATION
4.1A
A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.
•
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent
sealed combustion product.
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
As long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location
for an appliance is in the center of a building, thereby
allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a fl oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute
® (NFI) as NFI Gas
Specialists
www.nficertified.org
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
XIR3
IR3
NG
LP
NG
LP
Altitude (FT)
0-4,500
0-4,500
0-4,500
0-4,500
Max. Input (BTU/HR)
31,000
31,000
24,000
24,000
Max. Output (BTU/HR)
24,800
24,800
18,480
18,480
Efficiency (w/the fan on)
80%
80%
77%
77%
A.F.U.E. (maximum value)
77%
77%
76%
76%
Min. Inlet Gas Supply Pressure
4.5" Water
Column
11" Water
Column
4.5" Water
Column
11" Water
Column
Max. Inlet Gas Supply Pressure
7" Water
Column
13" Water
Column
7" Water
Column
13" Water
Column
Manifold Pressure (Under Flow
Conditions)
3.5" Water
Column
10" Water
Column
3.5" Water
Column
10" Water
Column
Содержание IR3N
Страница 36: ...36 W415 1033 A 10 12 11 48 40 44 46 42 43 41 45 50 ON OFF 35 34 49...
Страница 41: ...41 W415 1033 A 10 12 11 12 0 SERVICE HISTORY 43 1...
Страница 42: ...42 W415 1033 A 10 12 11 12 0 NOTES 44 1...
Страница 43: ...43 W415 1033 A 10 12 11 44 1...
Страница 44: ...44 W415 1033 A 10 12 11 44 1...