11.0  TROUBLE SHOOTING GUIDE

SYMPTOM

PROBLEM

TEST SOLUTION

Smoke enters the room 
during start-up.

Cold air blockage in chimney.

 

-

Burn a piece of newspaper to establish a draft.

Close the doors.

 

-

If the fl ame is not getting enough air, fi rst make sure the 
air control is open. If additional air is needed, open the 
doors a small crack only.

Kindling does not start - 
fi re smolders.

Cold air blockage in chimney.

 

-

Burn a piece of newspaper to establish a draft.

Not enough starter paper.

 

-

Use additional newspaper if necessary.

Not enough air.

 

-

First make sure the air control is fully open. If additional 
air is needed, a small crack in the doors is all that is 
needed.

Smoke enters the room 
while re-loading.

Insuffi cient draft.

 

-

Chimney height and outside conditions can negatively 
affect draft. In these cases a small amount of smoke 
may enter the home. Adding more pipe or a draft-
inducing cap may help.

 

-

Clean chimney

Appliance does not burn 
hot enough.

Wood is wet.

 

-

See the section on “Selecting Wood” for details.

Insuffi cient draft.

 

-

Chimney height and outside conditions can negatively 
affect draft. In these cases a small amount of smoke 
may enter the home. Adding more pipe or a draft-
inducing cap may help.

 

-

Clean chimney.

Air control is not wide open.

 

-

Make sure the air control is open all the way. Slide the 
control back and forth rapidly to insure the control is not 
stuck.

Blower does not run.

Appliance is not up to 
temperature.

 

-

This is normal. The blower will come on when the 
appliance is heated up enough to heat the room.

Electricity is cut to the blower.

 

-

Check the household breaker or fuse to make sure it is 
operable.

Door is ajar.

 

-

Appliance door must be closed for blower to operate.

Faceplate is cold.

This is normal.

 

-

The air leading into the fi rebox could come from the 
exterior. In these cases this air comes into the fi rebox 
and exits the chimney. This will not damage the 
appliance.

Appliance does not burn 
overnight.

The doors are not sealing.

 

-

See the section “Door Glass / Gasket Replacement” for 
details.

Appliance smoking.

 

-

Has the chimney had time to get hot?

 

-

Is there adequate supply of combustion air?

 

-

Is the outside air damper opened?

 

-

Is the smoke passage blocked anywhere in the 
appliance or chimney?

 

-

Is the smoke fl ow impeded by too long of a horizontal 
pipe or too many bends?

 

-

Is it a weak draft perhaps caused by a leaky chimney, a 
cold outside chimney, too short a chimney, or a chimney 
too close to a tree or a higher roof?

42.19

Содержание High Country NZ6000

Страница 1: ...cracks Before installing this unit contact the local building or fire authority and follow their guidelines Operate only with the doors tightly closed Burn wood behind the log retainer directly on th...

Страница 2: ...SING AN AIR COOLED CHIMNEY 22 5 3 MINIMUM CLEARANCE TO COMBUSTIBLES 23 5 4 MINIMUM ENCLOSURE CLEARANCES 23 5 5 MINIMUM MANTEL CLEARANCES 24 6 0 FINISHING 25 6 1 FACEPLATE 25 6 2 UPPER GRILL INSTALLATI...

Страница 3: ...N READ THROUGH THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM CAREFULLY THROUGHOUT YOUR PROJECT SEE CHIMNEY INSTALLATION SEE MINIMUM MANTEL CLEARANCES SEE FIREBRICK IN...

Страница 4: ...removed for servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe servicing...

Страница 5: ...BE KEPT FROM TOUCHING THE APPLIANCE WHEN IT IS HOT CON TACT YOUR LOCAL AUTHORIZED DEALER DISTRIBUTOR FOR SAFETY SCREENS THAT MAY BE AVAILABLE FOR THIS PRODUCT COMBUSTIBLE MATERIAL SUCH AS FIREWOOD WET...

Страница 6: ...cated at the top and sides of the opening 3 The dilution air is introduced high in the firebox above the baffle to cool the chimney 4 A single air control regulates the burn rate 5 Inside the firebox...

Страница 7: ...learances referred to throughout this manual are the minimum requirements Your appliance must be installed in accordance with all national and local building code standards and the standard of Chimney...

Страница 8: ...SEULS LES ACCESSOIRES FOURNIS PAR LE FABRICANT PEUVENT TRE UTILIS S COMPOSANTS REQUIS POUR L INSTALLATION EXIGENCES POUR LA CHEMIN E voir le manuel d instructions La chemin e doit tre certifi e selon...

Страница 9: ...gisters The hot air vent must be installed in an upward direc tion NEVER install in a downward direction The hot air gravity vent system is not to be connected to a central heating system No more than...

Страница 10: ...NTAIN A FIRE SMOKE SPILLAGE CAN ALSO SET OFF SMOKE ALARMS NEGATIVE PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY AFFECT YOUR APPLIANCE TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION THE APPLIANCE M...

Страница 11: ...gh the openings in the left and right hand sides Decide on the most convenient location for the fresh air inlet ducts and hoods which may be installed above or below floor level The fresh air inlet du...

Страница 12: ...viewing EMBER STRIP See HEARTH EXAMPLES Section HEARTH EXTENSIONS ARE TO BE INSTALLED ONLY AS DESCRIBED TO PREVENT HIGH TEMPERATURES FROM OCCURRING ON CONCEALED COMBUSTIBLE MATERIALS HEARTH EMBER STRI...

Страница 13: ...metal strip or both to prevent sparks and embers from falling into this area HEARTH EXTENSION Elevated hearths must be constructed of noncombustible materials such as cement blocks or bricks While th...

Страница 14: ...OR MARBLE MIN 1 CEMENT BOARD PLYWOOD INCREASE HEADER HEIGHT THIS DIMENSION See Framing section RAISED HEARTH EMBER STRIP MIN 1 4 TILE OR MARBLE MIN 1 CEMENT BOARD COMBUSTIBLE FLOOR 20 MIN 18 MIN EMBE...

Страница 15: ...or the United states Installation of all types of factory built chimney systems is to be in accordance with the chimney manufacturers installation instructions An appropriate chimney manufacturers anc...

Страница 16: ...or or ceiling that the chimney passes through 3 Hold a plumb bob from the underside of the roof to determine where the opening in the roof should be Cut and frame the roof opening maintaining proper 2...

Страница 17: ...her than any wall roof or building within 10 feet If the chimney extends more than 5 feet above the roof it must be secured using a roof brace or guide wires A raincap must be installed to avoid inter...

Страница 18: ...N REQUIRE STRUCTURAL SUPPORT TO REDUCE OFF CENTER LOADING AND TO PREVENT CHIMNEY SECTIONS FROM SEPARATING AT THE CHIMNEY JOISTS THE CHIMNEY SHOULD NOT BE BUILT WITH AN OFFSET ANGLE IN EXCESS OF 45 IN...

Страница 19: ...ibutor NOTE The flue tile support is to be suspended on appropriate lintels 62 4B ANGLE IRON RESTS ON BRICK SIDE WALLS FREE OF UNIT FLUE TILE HI TEMP GASKET ANGLE IRON TO SUPPORT CHIMNEY WEIGHT FLUE T...

Страница 20: ...himney manufacturer s instructions for installing the chimney KNOCK OUT 1 INSULATION 2 STARTER COLLAR 4 RING 3 AVERTIS SEMENT AIR COMBURANT SEULEMENT WARNIN G COMBUSTIO N AIR ONLY WARNIN G BLOW ER CON...

Страница 21: ...NCE BODY IT IS RECOMMENDED THAT THE WALLS OF THE APPLI ANCE ENCLOSURE BE FINISHED I E DRYWALL SHEETROCK AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME THIS WILL ENSURE THAT CLEARANCE TO COMBUSTI...

Страница 22: ...stibles Cement board Metal Studs The appliance face and enclosure ceiling must be framed using 2x4 metal studs The minimum enclosure ceiling height is 7 feet Non combustible materials cement board and...

Страница 23: ...iner 1 2 Cement board finishing A Shown with air intake liner coiled to create a cold trap OR A minimum of 6 is required to combustibles from the side of the unit This is only if the intake liner is r...

Страница 24: ...URE ALL CLEARANCES I E BACK SIDE TOP VENT MANTEL FRONT ETC ARE CLEARLY MAINTAINED WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION...

Страница 25: ...MBURANT SEULE MENT WARNIN G COMBUSTION AIR ONLY WARNIN G BLO W ER CONNECTION ONLY AV ERTISSEMENT CONNEXIO N DE LA SOUFF LE RIE SEULE MENT A Remove the facing template held in place with the 12 screws...

Страница 26: ...haft through the door and the latch Secure with 2 flat washers and a nut Feed the handle through the handle spacer and into the handle shaft LEFT DOOR HANDLE FIXED Insert the handle shaft through the...

Страница 27: ...shings AV ER TISS EM EN T AI R CO MBU RA NT SE UL EM EN T WAR NI NG CO MBU ST IO N AI R ONL Y WAR NI NG BL OW ER CO NN EC TION ONL Y AV ER TISS EM EN T CO NN EX IO N DE LA SO UF FL ER IE SE UL EM EN T...

Страница 28: ...ND HANDLE INSTALLATION Install the air control threaded rod and knob Place the gasket and the secondary air tube W010 1594 against the rear of the firebox onto the studs and secure using brass nuts 6...

Страница 29: ...THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERA TURES THAT COULD DAMAGE THE APPLIANCE CHIMNEY AND THE SURROUNDING ENCLOSURE Place the side and rear firebricks against the wall For easy start up open by pa...

Страница 30: ...IT 12 3 8 10 1 2 OUTSIDE WALL INSIDE WALL LEVEL SURFACE BLOW ER HOUSING WA RN IN G CO MB US TIO N AI R WA RN IN G BL OW ER CO NN EC TIO N ON LY AV ER TIS SE ME NT CO NN EX IO N DE LA SO UF FL ER IE SE...

Страница 31: ...g from the appliance D Electrical Connection a Remove the junction box covers on the appliance and the blower b Removing the junction box cover on the appliance exposes 4 black labeled wires Two wires...

Страница 32: ...of the appliance enclosure to ensure proper air flow around the firebox The 6 circulation air inlet pipe may be connected to either the NZ64 blower kit or the NZ150 KT kit Avoid terminating higher tha...

Страница 33: ...0594 D 08 23 11 33 6 13 SMOKE SHELF AIR WASH PLATE SMOKE SHELF EXTENSION To reduce smoke spillage due to a poor chimney draft the NZ6000 can be equipped with an optional smoke shelf extension kit NZ...

Страница 34: ...ood has cracks in the end grain Cut the wood so that it will fit horizontally front to back making for easier loading and less of a likelihood that the wood will roll onto the glass Manufactured firel...

Страница 35: ...s using medium sized wood to refuel frequently are much more efficient 90 1 A slight humming sound may be heard depending on the location of the blower This sound may be minimized by turning down the...

Страница 36: ...D LATCHED EXCEPT DURING START UP AND RE FUELING Draft is the force which moves air from the appliance up through the chimney The amount of draft in your chimney depends on the length of the chimney lo...

Страница 37: ...ed to encase a bed of coals that sustains the fire Loosely stacked wood burns quicker than a tightly packed load Wood burns in cycles rather than giving a steady output of heat It is best to plan thes...

Страница 38: ...S WEAR GLOVES TO PREVENT INJURY DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED OR WHEN USING A SPARK SCREEN AS UNSTABLE WOOD COULD FALL OUT OF THE FIRE CHAMBER CREATING A FIRE HAZARD TO Y...

Страница 39: ...lly drawing heated room air up the chimney certainly not desirable Always oper ate with the doors fully closed once the medium sized logs have caught fire You can now add larger pieces of wood and ope...

Страница 40: ...inutes depending on the size of the load reduce the draft control setting making sure that the fire is not extinguished D In the morning the appliance should still be hot with embers in the coal bed S...

Страница 41: ...1 ASH REMOVAL PROCEDURES IMPROPER DISPOSAL OF ASHES RESULT IN FIRES DO NOT DISCARD ASHES IN CARDBOARD BOXES DUMP IN BACK YARDS OR STORE IN GARAGES IF USING A VACUUM TO CLEAN UP ASHES BE SURE THE ASHE...

Страница 42: ...ow to handle a chimney fire After the chimney fire is out clean and inspect the chimney or chimney liner for stress and cracks prior to lighting another fire Also check combustibles around the chimney...

Страница 43: ...the glass is not kept clean permanent discolouration and or blemishes may result Normally a hot fire will clean the glass The most common reasons for dirty glass include not using sufficient fuel to...

Страница 44: ...he bracket by removing the four screws G Secure the new blower to the existing bracket using the four screws H Slide the new blower bracket assembly into the housing Ensure that the blower bracket sli...

Страница 45: ...E 21 W290 0121 GASKET SECONDARY AIR TUBE 22 W450 0028 NUT HEX BRASS 10 0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts Normally all...

Страница 46: ...OX PAINT 42 W470 0017 WROUGHT IRON PAINT 43 W062 0018 BLOWER NZ64 44 KB35 VARIABLE SPEED CONTROL INCL KNOB 45 W010 1184 LEFT DOOR ASSEMBLY 46 W010 1183 RIGHT DOOR ASSEMBLY 47 W325 0029 DOOR HANDLE BIR...

Страница 47: ...small amount of smoke may enter the home Adding more pipe or a draft inducing cap may help Clean chimney Air control is not wide open Make sure the air control is open all the way Slide the control ba...