 Install one screw into the top hole of stopper blocks.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada        •  1(866)820-8686         

 • www.napoleonfireplaces.com

W415-1824 / 03.09.18

4

5

Install two stopper blocks around the bypass damper rod.

Open both doors and remove by loosening set screws 

on hinges and lifting up until the hinge pins clear the door 

hinges. Set aside. 

3

Remove the 9 screws securing the face plate to the 

appliance.  

   

AIR CONTROL 

SLOT

FACE PLATE

X9

6

1” 

(25mm)

Stopper blocks should be located 1” (25mm) 

back from the notch on the bypass damper rod.

Stopper block

Notch

X8

**

**

**Use 2 x 

longer screws