9.3 TEMPERATURE 

DISPLAY

A. 

With the system in the “OFF” position, press the 
Thermostat Key and the Mode Key at the same 
time to change from degrees F to C. 

B. 

Look at the LCD screen on the Transmitter to 
verify that a C or F is visible to the right of the 
Room Temperature display.

35.5

73

°F

23

°C

The remote control has six (6) 

fl

 ame levels. With the 

system on and the 

fl

 ame level at the maximum, press 

the Down Arrow Key once and it will reduce the 

fl

 ame 

height by one step until the 

fl

 ame is turned off. 

The Up Arrow Key will increase the 

fl

 ame height each 

time it is pressed. If the Up Arrow Key is pressed while 
the system is on but the 

fl

 ame is off, the 

fl

 ame will 

come on the high position. A single “beep” will con

fi

 rm 

reception of the command.

35.8

76

°F

ON

OFF

76

°F

ON

76

°F

ON

76

°F

ON

Hi

FLAME OFF

FLAME AT LEVEL 1

FLAME AT LEVEL 5

FLAME AT “HI” LEVEL 6

9.4 FLAME 

HEIGHT

9.5 BLOWER 

SPEED

If the appliance is equipped with a hot air circulating fan, 
the speed of the fan can be controlled by the remote 
system. The fan speed can be adjusted through six (6) 
speeds. 

A. 

Use the Mode key to guide you to the fan control 
icon. 

B. 

Use the Up/Down Arrow keys to turn ON/OFF or       
adjust the fan speed. A single “beep” will con

fi

 rm 

reception of the command. 

NOTE: When the desired blower speed is selected, the blower will automatically come on 5 minutes 
after the main burner has been turned on and remain on twelve minutes after it has been turned off.

35.9A

76

°F

ON

68

76

°F

ON

Hi

Содержание HDX40NT-1

Страница 1: ...ly call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a...

Страница 2: ...NCE TO COMBUSTIBLES 24 5 2 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES 25 5 3 ALCOVE INSTALLATION 27 5 4 MINIMUM MANTEL CLEARANCES 28 6 0 FINISHING 29 6 1 DOOR REMOVAL INSTALLATION 29 6 2 LOG PLACEMEN...

Страница 3: ...ES TO COMBUSTIBLE ENCLOSURES section for drywall or other combustible material Framing see FRAMING section Side Wall Venting see VENTING section Enclosures see the section MINIMUM CLEARANCE TO COMBUST...

Страница 4: ...e appliance is a vented gas fired appliance Do not burn wood or other materials in the appliance It is imperative that the control compartments burners and circulating blower and its passageway in the...

Страница 5: ...sealed combustion product ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATI...

Страница 6: ...ntrol system Four 1 5 volt AA batteries not supplied are required for the battery pack included in the system Use Alkaline batteries only 2 3 GENERAL INFORMATION FOR YOUR SATISFACTION THIS APPLIANCE H...

Страница 7: ...OPTIONNELLE GZ550 KT GD65 CE FOYER GAZ VENTIL S NE DOIT PAS TRE UTILIS AVEC DES FILTRES AIR ET NE DOIT PAS TRE UTILIS AVEC UN COMBUSTIBLE SOLIDE UTILISER AVEC LES PORTES VITR ES HOMOLOGU ES AVEC CETTE...

Страница 8: ...GAP IS MAINTAINED THESE SPACERS MUST NOT BE REMOVED 3 1 VENTING LENGTHS AND COMPONENTS Use only Wolf Steel Simpson Dura Vent Selkirk Direct Temp American Metal Amerivent or Metal Fab venting componen...

Страница 9: ...ng the appliance and the air terminal connections when using flexible venting Horizontal runs may have a 0 rise per foot however for optimum performance it is recommended that all horizontal runs have...

Страница 10: ...eted the bottom air slot is located a minimum 12 above grade The maximum allowable vent length is 10 for a fireplace and 8 for a stove 9 1A 30 MIN 12 MIN TO GRADE 3 3 SPECIAL VENT INSTALLATIONS 3 3 1...

Страница 11: ...ring buildings P 8 8 Roof must be non combustible without openings Q 3 3 See chart for wider wall dimensions R 6 6 See chart for deeper wall dimensions The terminal shall not be installed on any wall...

Страница 12: ...l rise equal to or greater than the horizontal run 3 times the vertical rise equal to or greater than the horizontal run 3 5 VENT APPLICATION FLOW CHART 14 1 For the following symbols used in the vent...

Страница 13: ...5 FT HO 03 three 90 elbows 90 03 270 90 5 4 FT HT HR HO 4 5 5 4 9 9 FT HT VT 9 9 11 20 9 FT Formula 1 HT VT 9 9 11 Formula 2 HT VT 40 FT 20 9 40 Since both formulas are met this vent configuration is...

Страница 14: ...7 6 16 7 FT Formula 1 HT 4 2 VT 4 2 VT 4 2 x 6 25 2 FT 10 7 25 2 Formula 2 HT VT 24 75 FT 16 7 24 75 Since both formulas are met this vent configuration is acceptable 0 5 15 20 100 50 150 12 5 24 57 1...

Страница 15: ...Formula 1 HT VT Formula 2 HT VT 40 feet Example V1 5 FT V2 6 FT V3 10 FT VT V1 V2 V3 5 6 10 21 FT H1 8 FT H2 2 5 FT HR H1 H2 8 2 5 10 5 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 10 5 8 1 18...

Страница 16: ...2 1 1 5 4 5 FT H1 6 FT H2 2 FT HR H1 H2 6 2 8 FT HO 03 four 90 elbows 90 03 360 90 8 1 FT HT HR HO 8 8 1 16 1 FT HT VT 16 1 4 5 20 6 FT Formula 1 HT 3VT 3VT 3 x 4 5 13 5 FT 16 1 13 5 Since this formul...

Страница 17: ...N OF THE APPLIANCE FOLLOW THE VENTING INSTRUCTIONS EXACTLY ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED RTV HIGH TEMP SILICONE SEALANT W573 0002 NOT SUPPLIED OR B...

Страница 18: ...order specific kits required A Determine the air terminal location cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1 clearance between the vent pipe an...

Страница 19: ...finished wall surface Apply a heavy bead of the high temperature sealant W573 0007 Mill Pac not supplied to the inner sleeve of the air terminal Slip the vent pipe a minimum of 2 over the inner sleev...

Страница 20: ...connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure that the air terminal connector is properly centred within the flashing gi...

Страница 21: ...rs of the base Use 10 hex head screws inserted through the holes in the base to secure For free standing products contact your local authorized dealer distributor for the appropriate securing kit For...

Страница 22: ...CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE HIGH PRESSURE WILL DAMAGE VALVE DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS LINE AT TEST PRESSURES ABOVE 1 2 PSIG VALVE SETTINGS HAVE BEEN FACTORY SET...

Страница 23: ...s best to frame your appliance after it is positioned and the vent system is installed Frame to local building codes It is not necessary to install a hearth extension with this appliance When roughing...

Страница 24: ...e a minimum clearance of 18 at the top of the vent pipe See MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES section Use firestop spacer W010 1800 supplied where vent pipe penetrates combustible walls VERT...

Страница 25: ...ed that the enclosure be ventilated at the top and bottom to circulate the hot air See VENTING section 84 46 38 9 1 2 NON COMBUSTIBLE MATERIAL 2 1 WOOD HEADER 62 MINIMUM PLUS RISE FRONT HOOD 1 COMBUST...

Страница 26: ...hereof are suitable Materials that are reported as passing ASTM E 136 Standard Test Method for Behaviour of Materials in a Vertical Tube Furnace at 750 C and UL763 shall be considered non combustible...

Страница 27: ...combustibles are maintained Non combustible material can be used provided the minimum clearances to combustible materials are applied The minimum enclosure volume must be increased by no less than the...

Страница 28: ...OF FIRE MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT ENSURE ALL CLEARANCES I E BACK SIDE TO...

Страница 29: ...N AS ILLUSTRATED DO NOT STRIKE SLAM OR SCRATCH GLASS DO NOT OPERATE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED FACING AND OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPE...

Страница 30: ...N PROPERLYAND DELAYED IGNITION MAY OCCUR THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE The individual logs can be easily identified by the numbers cast on the underside of each log PhazerTM log...

Страница 31: ...elayed ignition PHAZERTM logs glow when exposed to direct flame Use only certified glowing embers and PHAZERTM logs available from your Authorized dealer 6 3 GLOWING EMBER PLACEMENT GLOWING EMBERS GLO...

Страница 32: ...of the rear log support Ensure the clusters are sitting flat D Place the large notched rocks along the inside and outside edges of the rock support as desired E Place the remaining refractory rocks ar...

Страница 33: ...THE APPLIANCE THE WIRE HARNESS PROVIDED IN THE BLOWER KIT IS A UNIVERSAL HARNESS WHEN INSTALLED ENSURE THAT ANY EXCESS WIRE IS CONTAINED PREVENTING IT FROM MAKING CONTACT WITH MOVING OR HOT OBJECTS 5...

Страница 34: ...bsence of local codes use the current CSA C22 1 Canadian electrical code in Canada or the ANSI NFPA 70 national electrical code in the United States Drywall dust will penetrate into the blower bearing...

Страница 35: ...sembly to the outer shell on the left side of the fire place and remove the junction box assembly B Remove the one screw that secures the junction box to the junction box plate and slide off the clip...

Страница 36: ...0 feet 18 gauge 40 feet A 20 length of wire is connected to the main burner switch leads Connect this wire to the wall switch or thermostat However if a greater length is required route 2 strand solid...

Страница 37: ...wise to off Located behind the access panel G Wait five 5 minutes to clear out any gas If you smell gas including near the floor STOP Follow B in the above safety information on this label If you don...

Страница 38: ...3 times to indicate that it is ready to synchronize with a transmitter D Install the 3 AAA batteries into the transmitter battery bay located on the base of the transmitter then press the ON button T...

Страница 39: ...em is on but the flame is off the flame will come on the high position A single beep will confirm reception of the command 35 8 76 F ON OFF 76 F ON 76 F ON 76 F ON Hi FLAME OFF FLAME AT LEVEL 1 FLAME...

Страница 40: ...to guide you to the CPI mode icon Transmitter in the OFF position B Press the UP DOWN to switch between IPI and CPI modes A single BEEP will confirm reception of the command Note If the system is equi...

Страница 41: ...m water column for propane Check that main burner is operating on HI Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water colum...

Страница 42: ...e burner ports The flame may not appear yellow immediately allow 15 to 30 minutes for the final flame colour to be established AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INSTALLER AIR SHU...

Страница 43: ...rocks or glass Failure to properly position the media may cause carboning which can be distributed in the surrounding living area F Check to see that the main burner ignites completely on all openings...

Страница 44: ...GLASS DO NOT OPERATE APPLIANCE WITH GLASS REMOVED CRACKED BROKEN OR SCRATCHED 11 3 CARE OF GLASS 5 1 DO NOT CLEAN GLASS WHEN HOT DO NOT USE ABRASIVE CLEANERS TO CLEAN GLASS Buff lightly with a clean...

Страница 45: ...T PARTS COMPONENTS REF PART NO DESCRIPTION 1a W725 0056 S I T MODULATION VALVE NG 1b W725 0057 S I T MODULATION VALVE LP 2a W010 2763 PILOT ASSEMBLY S I T NG 2b W010 2808 PILOT ASSEMBLY S I T LP 3a W4...

Страница 46: ...SANDSTONE 43 PRPH40 PORCELAIN REFLECTIVE RADIANT PANELS 44 HD540KT FACE PLATE WITH OPERABLE SCREEN DOORS 45 ANIH ANDIRONS 46 HDF40K 4 SIDED FRAME BLACK 46 HDF40N 4 SIDED FRAME BROWN 46 HDF40P 4 SIDED...

Страница 47: ...EF PART NO DESCRIPTION 61 GD 410 1 12 TO 7 12 PITCH 62 GD 411 8 12 TO 12 12 PITCH 63 GD 412 FLAT ROOF 64 W490 0074 5 8 INNER OUTER SLEEVE 65 W670 0007 5 8 TERMINAL 66 W170 0086 STORM COLLAR 67 W010 04...

Страница 48: ...water column for natural gas or 10 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER TORQU...

Страница 49: ...x when locked out Turn off power supply and remove batteries if used from the back up battery pack 2 To reset the DFC Board when the board goes into a lock out condition and the LED is blinking 3 time...

Страница 50: ...nlet pressure can cause the pilot flame to lift The sensor rod may need cleaning Poor grounding between pilot assembly and gas valve Verify that the wire harness is firmly connected to module Damaged...

Страница 51: ...plated trim or other components due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON All parts replaced under th...

Страница 52: ...52 W415 1089 08 08 12...

Страница 53: ...56 W415 1089 08 08 12...

Страница 54: ...nts par l eau les dommages caus s par les intemp ries de longues p riodes d humidit la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de NAPOL ON...

Страница 55: ...injecteur ou une pression d arriv e trop lev e peut causer la fl amme de la veilleuse se d tacher La tige de la sonde a possiblement besoin d tre nettoy e Mauvaise mise la terre entre l assemblage de...

Страница 56: ...m thodes suivantes pour r initialiser le syst me 1 Pour r initialiser la bo te d allumage lorsqu elle a t verrouill e coupez l alimentation lectrique et retirez les piles s il y a lieu du r cepteur 2...

Страница 57: ...l fonctionne HI APR S AVOIR PRIS LA LECTURE DES PRESSIONS ASSUREZ VOUS DE TOURNER FERMEMENT LES VIS VERS LA DROITE POUR SCELLER NE SERREZ PAS TROP FORT V rifi ez pour des fuites en appliquant une solu...

Страница 58: ...ON POUR TOIT REF N O DE PI CE DESCRIPTION 61 GD 410 PENTE 1 12 7 12 62 GD 411 PENTE 8 12 12 12 63 GD 412 TOIT PLAT 64 W490 0074 MANCHON INT RIEUR EXT RIEUR 5 8 65 W670 0007 TERMINAISON 5 8 66 W170 008...

Страница 59: ...IFS SIMILIBRIQUES PIERRE DE SABLE 43 PRPH40 PANNEAUX R FLECTEURS RADIANTS EN PORCELAINE 44 HD540KT FA ADE AVEC PORTES GRILLAG ES 45 ANIH BORNES DE CHENET 46 HDF40K CONTOUR 4 C T S NOIR 46 HDF40N CONTO...

Страница 60: ...725 0056 SOUPAPE MODULATION PSE GN 1b W725 0057 SOUPAPE MODULATION PSE PL 2a W010 2763 ASSEMBLAGE DE VEILLEUSE PSE GN 2b W010 2808 ASSEMBLAGE DE VEILLEUSE PSE PL 3a W455 0068 INJECTEUR DE VEILLEUSE PS...

Страница 61: ...APPEZ PAS NE CLAQUEZ PAS ET N GRATIGNEZ PAS LA PORTE VITR E NE FAITES PAS FONCTIONNER L APPAREIL LORSQUE LA PORTE VITR E EST ENLEV E FISSUR E BRIS E OU GRATIGN E 56 2 5 1 NE PAS NETTOYER LA VITRE LORS...

Страница 62: ...ion INSTALLATION ENL VEMENT DE LA PORTE 3 D vissez le couvercle de la lentille et enlevez l ampoule en la tirant Remplacez par des pi ces Wolf Steel lt e uniquement W387 0013 4 NOTE Lorsque vous manip...

Страница 63: ...eurs produisent des fl ammes Nettoyez tous les orifi ces qui n ont pas de fl amme ou dont la fl amme ne br le pas ad quatement D Assurez vous que la fl amme de la veilleuse est assez puissante pour en...

Страница 64: ...t ne pas tre jaune imm diatement allouez de 15 30 minutes pour que la couleur finale de la flamme se stabilise LE R GLAGE DU VOLET D AIR DOIT TRE EX CUT PAR UN TECHNICIEN OU INSTALLATEUR QUALIFI VENTU...

Страница 65: ...que le br leur principal fonctionne HI APR S AVOIR PRIS LA LECTURE DES PRESSIONS ASSUREZ VOUS DE TOURNER FERMEMENT LES VIS VERS LA DROITE POUR SCELLER NE SEREZ PAS TROP FORT V rifi ez pour des fuites...

Страница 66: ...able l op ration du CPI Si l interrupteur est plac IPI il fonctionnera seulement en IPI ind pendamment du r glage sur la t l commande 35 22 76 76 ON ON F F IPI CPI Cette fonction verrouillera les touc...

Страница 67: ...ue la fl amme est teinte la fl amme s allumera en position lev e Un seul bip confi rmera la r ception de la commande 35 8 76 F ON OFF 76 F ON 76 F ON 76 F ON Hi FLAMME TEINTE FLAMME AU NIVEAU 1 FLAMME...

Страница 68: ...bouton MARCHE Le r cepteur SONNERA 4 fois pour indiquer que l ordre du t l commande est accept et r gle au code particulier de cet metteur Le syst me est maintenant initialis NOTE LE PROCESSUS D INIT...

Страница 69: ...entation lectrique l appareil et remettez les piles dans l metteur 11 Appuyez sur le bouton ON de la t l commande Vous devriez entendre un bip du r cepteur vous indiquant que la communication est bonn...

Страница 70: ...teur mural doit tre install dans un endroit pratique pour le br leur La longueur maximale d pend du calibre du fi l DIAM TRE LONGEUR MAX calibre 14 100 pieds calibre 16 60 pieds calibre 18 40 pieds Un...

Страница 71: ...rivation la paroi ext rieure du c t gauche de l appareil puis retirez l assemblage de la bo te de d rivation 2 Enlevez la vis qui fi xe la bo te de d rivation la plaque de la bo te et glissez la bo t...

Страница 72: ...bsence de codes locaux utilisez la version courante du Code canadien de l lectricit CSA C22 1 au Canada ou le National Electrical Code ANSI NFPA 70 aux tats Unis La poussi re de gypse p n trera dans l...

Страница 73: ...ttre de placer l assemblage sur le c t GRILLE AVANT SUPPORT DE B CHE ARRI RE PANNEAU D ACC S VIS DU POURTOUR AVERTISSEMENT RISQUE D INCENDIE ET DE CHOC LECTRIQUE COUPEZ L ALIMENTATION EN GAZ ET L ALIM...

Страница 74: ...35 W415 1089 08 08 12 1 2 1 2 1 2 1 Retirez le papier dorsal du logo Placez le logo sur la porte vitr e ou sur le panneau d acc s inf rieur comme illustr 6 6 MISE EN PLACE DU LOGO...

Страница 75: ...posent plat D Placez les grosses roches encoch es le long des bordures int rieures et ext rieures du support de roches comme vous le d sirez E Placez les autres roches autour du br leur comme vous le...

Страница 76: ...es certifi es PHAZER TM disponibles aupr s de votre d taillant autoris BRAISES BRAISES INCANDESCENTES INCANDESCENTES E Alignez les trous en dessous de la b che droite W135 0447 avec les tiges de la b...

Страница 77: ...nn e sur le support et la tige centrale C Alignez le trou en dessous de la b che avant gauche W135 0450 avec la vis et l espaceur situ s du c t gauche du br leur Le milieu de cette b che s appuie cont...

Страница 78: ...DE S CURIT ET DOIVENT TRE AD QUATEMENT VERROUILL S NE FAITES PAS FONCTIONNER L APPAREIL LORSQUE LES LOQUETS SONT D VERROUILL S LES MAT RIAUX DE FA ADE ET DE FINITION NE DOIVENT PAS NUIRE LA CIRCULATIO...

Страница 79: ...LETTRE LORSQUE VOUS UTILISEZ DE LA PEINTURE OU DU VERNIS COMME FINITION POUR VOTRE TABLETTE ASSUREZ VOUS QU ILS SOIENT R SISTANTS LA CHALEUR AFIN DE PR VENIR LA D COLORATION 73 1 Le d gagement d une...

Страница 80: ...riaux combustibles sont respect s Vous pouvez utiliser un mat riau incombustible pourvu que les d gagements minimaux aux mat riaux combustibles soient appliqu s Le volume minimal de l enceinte doit t...

Страница 81: ...36 m thode de test standard du comportement des mat riaux dans une fournaise avec tube vertical 750 C Standard Test Method for Behaviour of Materials in a Vertical Tube Furnace at 750 C et la norme UL...

Страница 82: ...it ventil e dans le haut et le bas afi n de faire circuler l air chaud Voir la section VACUATION MAT RIAUX INCOMBUSTIBLES ENTRETOISE DE BOIS 62 MINIMUM PLUS LA PENTE HOTTE AVANT COMBUSTIBLE INCOMBUSTI...

Страница 83: ...il Les sections d vents horizontales dans l enceinte requi rent un d gagement minimal de 18 sur le dessus Voir la section D GAGEMENT MINIMAL AUX ENCEINTES COMBUSTIBLES Utilisez l espaceur coupe feu W0...

Страница 84: ...i nition pour maintenir les d gagements NE RIEN CONSTRUIRE DANS CETTE ZONE CETTE ZONE DE 14 PO DE LARGEUR CENTR E LE LONG DE L AVANT DE L APPAREIL DOIT REST E LIBRE AFIN D OFFRIR UN D GAGEMENT AD QUAT...

Страница 85: ...MAT RIAUX SONT APPROPRI S LES MAT RIAUX R PONDANT LA NORME ASTM E 136 M THODE DE TEST STANDARD DU COMPORTEMENT DES MAT RIAUX DANS UNE FOURNAISE AVEC TUBE VERTICAL 750 C ET LA NORME UL763 SONT CONSID R...

Страница 86: ...ifi ez pour des fuites de gaz en appliquant une solution d eau savonneuse N utilisez pas une fl amme nue AVERTISSEMENT RISQUE D INCENDIE D EXPLOSION OU D ASPHYXIE ASSUREZ VOUS QU IL N Y AIT AUCUNE SOU...

Страница 87: ...re situ s aux coins avant gauche et droit de la base Lors d une installation dans une maison mobile l appareil doit tre fi x au plancher Fixez l aide de vis 10 t te hexagonale ins r es dans les trous...

Страница 88: ...une fois fi x e E Enlevez les clous des bardeaux sur le dessus et les c t s du connecteur de terminaison Placez le solin par dessus le connecteur de terminaison en laissant un minimum de 3 4 de connec...

Страница 89: ...eux joint de scellant haute temp rature W573 0007 Mill Pac non fourni Glissez la gaine fl exible sur le manchon int rieur de la terminaison en assurant un chevauchement minimal de 2 et fi xez l aide d...

Страница 90: ...placement de la terminaison d coupez et charpentez une ouverture dans le plafond et le toit pour laisser le d gagement minimal de 1 entre le conduit d vent et tout mat riau combustible Essayez de posi...

Страница 91: ...BSERVER LES INSTRUCTIONS D VACUATION LA LETTRE TOUS LES JOINTS DES CONDUITS INT RIEURS ET EXT RIEURS PEUVENT TRE SCELL S AVEC DU SCELLANT DE SILICONE ROUGE HAUTE TEMP RATURE RTV W573 0002 NON FOURNI O...

Страница 92: ...PI H 1 6 PI H 2 2 PI H R H 1 H 2 6 2 8 PI H O 0 03 quatre coudes 90 90 0 03 360 90 8 1 PI H T H R H O 8 8 1 16 1 PI H T V T 16 1 4 5 20 6 PI Formule 1 H T 3V T 3V T 3 x 4 5 13 5 PI 16 1 13 5 Puisque c...

Страница 93: ...ent Formule 1 H T V T Formule 2 H T V T 40 pieds Exemple V 1 5 PI V 2 6 PI V 3 10 PI V T V 1 V 2 V 3 5 6 10 21 PI H 1 8 PI H 2 2 5 PI H R H 1 H 2 8 2 5 10 5 PI H O 0 03 quatre coudes 90 90 0 03 360 90...

Страница 94: ...7 6 16 7 PI Formule 1 H T 4 2 V T 4 2 V T 4 2 x 6 25 2 PI 10 7 25 2 PI Formule 2 H T V T 24 75 PI 16 7 24 75 Puisque les deux formules sont respect es cette configuration d vacuation est acceptable 0...

Страница 95: ...03 270 90 5 4 PI H T H R H O 4 5 5 4 9 9 PI H T V T 9 9 11 20 9 PI Formule 1 H T V T 9 9 11 Formule 2 H T V T 40 PI 20 9 40 Puisque les deux formules sont respect es cette confi guration d vacuation e...

Страница 96: ...ticale plus grande ou gale la course horizontale 3 fois la course verticale plus grande ou gale la course horizontale 14 1 Les symboles suivants sont utilis s dans le calcul et les exemples d vacuatio...

Страница 97: ...sions d un mur plus large R 6 6 Voir le tableau pour les dimensions d un mur plus profond La terminaison ne doit pas tre install e sur quelconque mur ayant une ouverture entre la terminaison et le c t...

Страница 98: ...e 12 pouces au dessus du niveau du sol La longueur maximale permise de l vent est 10 pieds pour un foyer et 8 pieds pour un po le 9 1A 30 MIN NIVEAU DU SOL 12 MIN 3 3 INSTALLATIONS PARTICULI RES D VEN...

Страница 99: ...10 W415 1089 08 08 12 24 MIN 38 24 MAX 62 MIN PLUS L VATION 16 MIN 40 PIEDS MAX 3 PIEDS MIN 38 3 2 INSTALLATIONS TYPIQUES D VENTS Voir la section VACUATION...

Страница 100: ...erminaisons utilisez l ensemble d vents de 5 pieds GD420 ou l ensemble d vents de 10 pieds GD430 Pour une performance optimale de l appareil et une apparence optimale des fl ammes gardez la longueur d...

Страница 101: ...ons fournies dans l installation initiale NOTE Cet appareil doit tre install de mani re ce que le conduit d vacuation et de prise d air se prolongent sur toute la longueur de la chemin e Toute autre m...

Страница 102: ...ORSQU IL EST INSTALL AVEC LE PARE TINCELLES GD 565KT LE FOYER EST CONFORME LA NORME DE CERTIFICATION DE L ACG CR95 006 OPTIONAL FAN KIT SOUFFLERIE OPTIONNELLE GZ550 KT GD65 CE FOYER GAZ VENTIL S NE DO...

Страница 103: ...5 w c 10 0 w c CLASSEMENTS D EFFICACIT Mod le L tat Assurer AFUE HDX40NT 1 61 5 59 5 HDX40PT 1 61 5 59 5 IPI Intermittent Pilot Ignition System Le Syst me d Allumage de Pilote Intermittent Utiliser u...

Страница 104: ...nis Cet appareil convient pour installation dans une maison mobile si l installation est conforme aux normes actuelles pour les maisons mobiles quip es au gaz CAN CSA Z240 S RIE MM au Canada ou selon...

Страница 105: ...place avant d utiliser l appareil Cet appareil est un appareil gaz ventil Ne br lez pas de bois ou autres mat riaux dans cet appareil Il est primordial de garder propres les compartiments de contr le...

Страница 106: ...R LA PLAQUE D HOMOLOGATION Voir la section D GAGEMENTS MINIMAUX DE LA TABLETTE Voir la section D GAGEMENTS MINIMAUX AUX ENCEINTES COM BUSTIBLES pour les cloisons s ches ou autres mat riaux combustible...

Страница 107: ...BLES 26 5 2 D GAGEMENTS MINIMAUX AUX ENCEINTES COMBUSTIBLES 27 5 3 L INSTALLATION DE L ALC VE 29 5 4 D GAGEMENTS MINIMAUX DE LA TABLETTE 30 6 0 FINITIONS 31 6 1 ENL VEMENT ET INSTALLATION DE LA PORTE...

Страница 108: ...vez ses instructions Si vous ne pouvez pas rejoindre votre fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre faits par un installateur qualifi une agence d...