fi nishing

6.3  log placement

2

A.

 

Place the back log (1) into the fi rebox, pushing it as 

close to the fi rebox wall as possible and centered 

onto the log support pan.

B.

 

Place the front log (2) on the ember screen lining up 

the studs with the holes on the bottom of the log.

C.

Set the two cross-over logs (3, 4) into the pockets 

provided on both the front and rear logs as shown.

PHAZER

TM

 logs, glowing embers, and charcoal embers, exclusive to Wolf Steel Ltd., glow when exposed to 

direct fl ame, and provide a unique and realistic glowing effect that is different in every installation. Use only certifi ed 

PHAZER™

 logs, glowing embers, and charcoal embers available from your local authoriez dealer / distributor. 

Log colours may vary. During the initial use of the appliance, the colours will become more uniform as colour pig-

ments burn in during the heat-activated curing process.

1

3

4

Fig. 1

!

WARNING

•  Failure to position the logs in accordance with these diagrams or failure to use only logs specifi cally approved 

with this appliance may result in property damage or personal injury.

•  Logs must be placed in their exact location in the appliance. Do not modify the proper log positions, since 

appliance may not function properly and delayed ignition may occur.

•  The logs are fragile and should be handled with care.

note:

Ensure the left support tab and the two right 

support tabs are bent down to ensure the front 

burner fl ame does not get sucked beneath the 

front log.

note:

The ember screen frame has a minimal adjustment distance. When heating with propane, ensure the ember 

screen is secured as close to the rear of the fi rebox as possible

 (Fig. 1)

. T

his will ensure the log's distance from 

the fl ames, and prevent excess carbon and soot.

 When heating with natural gas, ensure the ember screen is 

secured as close to the glass door as possible 

(Fig. 2)

This will ensure the log's placement over the fl ames, and 

create a glowing effect on the log. 

Fig. 2

Содержание Haliburton GDS28-1NSB

Страница 1: ...rom a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer servic...

Страница 2: ...burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children and...

Страница 3: ...ease anemia those under the influence of alcohol those at high altitudes are more affected by carbon monoxide than others Failure to keep the primary air opening s of the burner s clean may result in...

Страница 4: ...tion 21 horizontal air terminal installation model GDS28 21 vertical air terminal installation 22 appliance vent connection 23 natural vent specifics 23 chimney installation 23 combustion air 23 insta...

Страница 5: ...ted This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on...

Страница 6: ...athroom unless the unit is a direct vent sealed combustion product The installation must conform with local codes or in absence of local codes the National Gas and Propane Installation Code CSA B149 1...

Страница 7: ...sceller l vacuation apr s avoir executer l entretien du syst me de prise d air Serial Number N de S rie W385 XXXX REFERENCE 161746 XXXX VENTED DECORATIVE GAS APPLIANCE NOT A SOURCE OF HEAT NOT INTENDE...

Страница 8: ...on GAS LINE ACCESS HOLE LOCATED IN PEDESTAL BASE 26 3 4 680mm 22 1 2 572mm 11 1 4 286mm 7 178mm AIR INTAKE 10 254mm 12 305mm 17 3 4 451mm 18 1 2 470mm 5 1 2 127mm 4 102mm FLUE SAFETY BARRIER 1 3 4 44m...

Страница 9: ...110 8 12 to 12 12 roof terminal kit GD 111 flat roof terminal kit GD 112 or periscope kit GD 180 for wall penetration below grade in conjunction with the appropriate venting components A terminal sha...

Страница 10: ...er start up and or carboning Use an adjustable pipe as the final length of rigid piping to the stove for ease of installation These vent kits allow for either horizontal or vertical venting of the app...

Страница 11: ...12 305mm above grade The maximum allowable vent length including both rise and run is 10 3m for a fireplace and 8 2m for a stove An insulation sleeve is illustrated in the top vent image below use onl...

Страница 12: ...ang N 16 40 6cm 16 40 6cm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0...

Страница 13: ...of 40 feet 12 2m Horizontal run vertical rise to maximum of 40 feet 12 2m Vertical Termination For the following symbols used in the venting calculations and examples are greater than equal to or gre...

Страница 14: ...0 9m V2 8 FT 2 4m VT V1 V2 3 FT 0 9m 8 FT 2 4m 11 FT 3 4m H1 2 5 FT 0 8m H2 2 FT 0 6m HR H1 H2 2 5 FT 0 8m 2 FT 0 6m 4 5 FT 1 4m HO 03 three 90 elbows 90 03 270 90 5 4 FT 1 7m HT HR HO 4 5 FT 1 4m 5 4...

Страница 15: ...8m 16 7FT 5 1m Formula 1 HT 4 2 VT 4 2 VT 4 2FT 1 3m x 6FT 1 8m 25 2 FT 7 7m Formula 2 HT VT 24 75 FT 7 5m 16 7 FT 5 1m 24 75 7 5m Since both formulas are met this vent configuration is acceptable 90...

Страница 16: ...ple V1 5 FT 1 5m V2 6 FT 1 8m V3 10 FT 3 1m VT V1 V2 V3 5FT 1 5m 6FT 1 8m 10FT 3 1m 21FT 6 4m H1 8 FT 2 4m H2 2 5 FT 0 8m HR H1 H2 8FT 2 4m 2 5FT 0 8m 10 5 FT 3 2m HO 03 four 90 elbows 90 03 360 90 8...

Страница 17: ...HR H1 H2 6FT 1 8m 2FT 0 6m 8 FT 2 4m HO 03 four 90 elbows 90 03 360 90 8 1 FT 2 5m HT HR HO 8FT 2 4m 8 1FT 2 5m 16 1FT 4 9m HT VT 16 1FT 4 9m 4 5FT 1 4m 20 6 FT 6 3m Formula 1 HT 3VT 3VT 3FT 0 9m x 4...

Страница 18: ...ntake flex liner and the exhaust collar must be connected to the exhaust flexible liner Both Simpson Duravent and Selkirk co linear to co axial adaptors have been approved on this appliance Follow ven...

Страница 19: ...take vent pipe joints must be sealed using red RTV high temp silicone sealant W573 0002 not supplied or black high temp Mill Pac W573 0007 not supplied If using pipe clamps to connect rigid vent compo...

Страница 20: ...irestop top so that the vent shield covers the top of the vent within the opening Ensure that both spacer and shield maintain the required clearance to combustibles C Secure the spacer in place using...

Страница 21: ...ld and tighten This will prevent any materials such as insulation from filling up the 1 25mm air space around the pipe Caulking Vent Pipe Shield Vent Pipe Shield Vent Pipe Collar Firestop underside of...

Страница 22: ...over the air terminal connector leaving a min 3 4 19mm of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure...

Страница 23: ...ible on the exterior pipes once installation is completed An optional decorative black band may be available with this appliance In the event that the venting must be disassembled care must be taken t...

Страница 24: ...insert the protective bushing Pull both spill switch wires through the bushing taking up any slack Replace the cover plate FOR MILLIVOLT Disconnect one of the black on off switch wires and attach to...

Страница 25: ...the chimney extends more than 5ft 1 5m above the roof it must be secured using a roof brace or guide wires A raincap must be installed to avoid internal damage and corrosion 3 FT 1m MIN 3 FT 1m MIN 1...

Страница 26: ...nce is equipped with a manual shut off valve to turn off the gas supply to the appliance Connect the gas supply in accordance to local codes In the absence of local codes install to the current CAN CS...

Страница 27: ...slam or scratch Do not operate appliance with glass removed cracked or scratched Facing and or finishing material must never overhang into the appliance opening The glass door assembly is a safety de...

Страница 28: ...frame Snap the rear handle hook to lock the latch closed To open the door repeat in reverse order HINGE PIN BUSHING CATCH SLOT DOOR LATCH WARNING Glass may be hot Do not touch glass until cooled If eq...

Страница 29: ...uring process 1 3 4 Fig 1 WARNING Failure to position the logs in accordance with these diagrams or failure to use only logs specifically approved with this appliance may result in property damage or...

Страница 30: ...ed to direct flame Use only certified glowing embers and PHAZER logs available from your local authorized dealer distributor WARNING Completely blocking the burner ports can cause an incorrect flame p...

Страница 31: ...ated above the spill switch bracket on the adaptor D Venting action is satisfactory if the flame stays lit Venting action is unsatisfactory if the flame extinguishes E If venting action is unsatisfact...

Страница 32: ...efore using the appliance Place near the IPI board If the back up is used it must be connected to this 6 volt battery pack supplied Do not connect to a 9 volt battery pack note PILOT W725 0062 NG W725...

Страница 33: ...d I Turn on the remote wall switch to the appliance J If the appliance will not operate follow instructions TO TURN OFF GAS and call your service technician or gas supplier A Set thermostat to lowest...

Страница 34: ...ll then begin the countdown for approximately seven days before shutting off the pilot if the appliance is not used This countdown will reset anytime the appliance main burner is used Therefore if the...

Страница 35: ...t continue to burn repeat steps E through I J With pilot lit turn gas knob counter clockwise to the ON position K If equipped with the flame adjustment valve push and turn the knob to high L Turn on a...

Страница 36: ...ith a soap and water solution Prior to pilot adjustment ensure that the pilot assembly has not been painted If overspray or painting of the pilot assembly has occurred remove the paint from the pilot...

Страница 37: ...fting from the burner ports The flame may not appear yellow immediately allow 15 to 30 minutes for the final flame colour to be established AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED INST...

Страница 38: ...r 5 If your appliance is equipped with a safety barrier cleaning may be necessary due to excessive lint dust from carpeting pets etc simply vacuum using the brush attachment 6 If your appliance is equ...

Страница 39: ...ld be performed by a qualified service technician The firebox becomes very hot during operation Let the appliance cool completely or wear heat resistant gloves before conducting service Never vacuum h...

Страница 40: ...are neither pinched nor interfere with the blower operation Re secure the air intake manifolds INSTALLATION THROUGH THE FIREBOX REPLACEMENT BLOWER ACCESS GASKET IS REQUIRED Turn off the electrical pow...

Страница 41: ...replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of appliance Instal...

Страница 42: ...GL 620 Left side log GL 620 W550 0001 W135 0061 12 13 11 10 5 6 7 8 9 Yes Glowing embers GL 620 W361 0016 Yes Yes ON OFF switch W660 0009 Trivet W010 2511 Yes Right side log GL 620 W135 0060 W715 0059...

Страница 43: ...100 0056 Main burner assembly W680 0008 Thermocouple Stocked Stocked Yes W010 0633 Pilot assembly NG w ignitor W290 0029 Pilot gasket W725 0042 Valve NG Yes Yes 14 14 14 14 14 14 14 14 14 12 13 14 14...

Страница 44: ...rifice 54 P W456 0040 Burner orifice 40 NG W100 0056 Main burner assembly W455 0070 Pilot orifice 62 NG Stocked Stocked Yes W010 2763 Pilot assembly NG W290 0029 Pilot gasket W725 0062 Valve NG Yes Ye...

Страница 45: ...fety barrier assembly 1 Stocked 23 23 23 5 23 4 23 3 23 1 7 6 23 2 23 8 AR28SS W660 0081 Wall mounted thermostat F45 F60 Hand held remote control 6 3 3 GS328SSB Satin chrome plated door GS328KSB Metal...

Страница 46: ...heck that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak test with a soap and water solution Air shutter improp...

Страница 47: ...ple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or swi...

Страница 48: ...rting or faulty Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Main burner goes out pilot stays on Venting is spilling Test with spill switch bypassed Che...

Страница 49: ...al DO NOT OVER TORQUE Leak test with a soap and water solution Air shutter improperly adjusted Return air shutter to specified opening see venturi adjustments section in the installation manual Carbon...

Страница 50: ...nded Receiver if equipped Reset program hold reset button on receiver and wait for 2 beeps Release after second beep Press small flame button on remote within 20 seconds you will hear an additional be...

Страница 51: ...ose one of the 3 methods below to reset the system 1 To reset ignition box when locked out Turn off power supply and remove batteries if used from the back up battery pack 2 To reset the DFC Board whe...

Страница 52: ...caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to the appliance combustion chamber heat exchanger plated trim or other components due to water weather damag...

Страница 53: ...C 02 08 21 53 service history 18 0 service history Appliance Service History This appliance must be serviced annually depending on usage Date Dealer Name Service Technician Name Service Performed Spec...

Страница 54: ...P P P P P P P PO O O O O O OL L L L L L L LE E E E E EO O O O O ON N N N C C C CE E EL L LE E EB BR RA AT TI IN NG G O OV VE ER R 4 40 0 Y YE EA AR RS S A A A O O O O O OF F F F F F H H H H H H H HO O...

Отзывы: