Napoleon GVFS60-N Скачать руководство пользователя страница 18

SYMPTOM

Pilot goes out while 

standing; Main burner 

is in ‘OFF’ position.

Flames are consis-

tently too large or too 

small. Carboning 

occurs.

Carbon is being 

deposited on logs or 

combustion chamber 

surfaces.

Exhaust fumes 

smelled in room, 

headaches.

Remote wall switch is 

in “off” position; main 

burner comes on 

when gas knob is 

turned to “ON” 

position.

PROBLEM

TEST SOLUTION

Gas piping is undersized.

Unit is over-fired or under-fired.

Air shutter has become blocked.

Flame is impinging on the logs or 

combustion chamber.

Not enough combustion air.

Not enough ventilation air.

Flame is impinging on the logs or 

combustion chamber.

Wall switch is mounted upside 

down.

Remote wall switch is grounding.

Remote wall switch wire is 

grounding.

Faulty valve.

-   Turn on all gas appliances and see if pilot flame flutters, 

    diminishes or extinguishes, especially when main burner 

    ignites. Monitor appliance supply working pressure.

-   Check if supply piping size is to code. Correct all undersized 

    piping.

-   Check pressure readings:

    Inlet pressure can be checked by turning screw (A) counter-

    clockwise 2 or 3 turns and then placing pressure gauge tubing 

    over the test point. Check with burner operating on “HI”. 

    Gauge should read 7” (minimum 4.5”) water column for 

    natural gas or 13” (11” minimum) water column for propane. 

    Outlet pressure can be checked the same as above using 

    screw (B). Check with burner operating on “HI”. Gauge should 

    read 3.5” water column for natural gas or 10” water column for 

    propane.

    AFTER TAKING PRESSURE READINGS, BE SURE TO 

    TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO 

    NOT OVERTORQUE.

    Leak test with a soap and water solution.

-   Ensure air shutter opening is free of lint or other obstructions.

-   Check that the logs are correctly positioned.

-   Open air shutter to increase the primary air. See air shutter 

    openings, page 15.

-   Check the input rate: check the manifold pressure and orifice 

    size as specified by the rating plate values.

-   Increase fresh air supply. (Use one of the methods described 

    in ANSI Z223.1 Section 5.3 or the applicable local code.)

-   Increase fresh air supply. (Use one of the methods described 

    in ANSI Z223.1 Section 5.3 or the applicable local code.)

-   Check that the logs are correctly positioned.

-   Open air shutter to increase the primary air. See air shutter 

    openings, page 15.

-   Check the input rate: check the manifold pressure and orifice 

    size as specified by the rating plate values.

-   Reverse.

-   Replace.

-   Check for ground (short); repair ground or replace wire.

-   Replace.

P

I

A

B

PILOT

N

O

L

O

T

H I

L O

FF

O

18

W415-0204 / F / 10.23.08

TP - TROUbLE ShOOTING_vF_2_SIT

Содержание GVFS60-N

Страница 1: ...one Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supp...

Страница 2: ...d ventilation air provisions 7 2 2 determining confined or unconfined space 8 2 3 Gas installation 9 2 4 electrical connection 9 3 0 finishing 10 3 1 cast front installation 10 3 2 log placement 10 3...

Страница 3: ...screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the heater It is imperative that the control compartments burners...

Страница 4: ...aused by misuse lack of maintenance accident alterations abuse or neglect and parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scrat...

Страница 5: ...Fuel Gas Code ANSI Z223 1 Installation Code which can be obtained from American Nation Standards Institute Inc or National Fire Protection Association Inc 1430 Broadway Batterymarch Park New York NY 1...

Страница 6: ...ter column for propane No external electricity 110 volts or 24 volts is required for the gas system operation Expansion contraction noises during heating up and cooling down cycles are normal and are...

Страница 7: ...K WALL BACK WALL ALCOVE A C A A B B 45 D OBJECT figure 2 0c figure 2 0b figure 2 0a 2 1 Combustion and ventilation air provisions This heater shall not be installed in a confined space or unusually ti...

Страница 8: ...added on openable windows and doors and C Caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wal...

Страница 9: ...ode 4 When connecting the gas line to the valve support the valve and ensure not to kink the line 5 Check for gas leaks by brushing on a soap and water solution DO NOT USE OPEN FLAME WARNING Do not co...

Страница 10: ...on 3 2 log placement Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition Phazertm logs glow when exposed to direct flame and provide a unique and realistic g...

Страница 11: ...xposed to direct flame however care should be taken to not block the burner ports Blocked ports can cause an incorrect flame pattern carbon deposits and delayed ignition Replacement loose material mus...

Страница 12: ...e blower housing 4 0 6 Remove the 2 screws from the side of the blower housing that you want the switch to be located on and re secure the on off switch Because the blower is thermally activated when...

Страница 13: ...nite burner K Turn on all electric power to the fireplace A Turn off all electric power to the fireplace if service is to be performed B Push in gas control knob slightly and turn clockwise to off Do...

Страница 14: ...oting Guide Carbon can be distributed in surrounding living area if the air shutter is improperly adjusted WARNING This procedure must be performed by a qualified service person Inspect the pilot for...

Страница 15: ...ically approved with this appliance may result in property damage or personal injury WARNING COMPONENTS REF PART NO DESCRIPTION 1 W725 0030 SIT VALVE NG 1 W725 0031 SIT VALVE LP 2 W010 0757 BURNER 3 W...

Страница 16: ...T BLOWER KIT 29 GS830 G GOLD TRIVET 29 GS830 C CHROME TRIVET 30 W550 0001 CHARCOAL EMBERS 31 W380 0002 VARIABLE SPEED SWITCH KNOB 32 KB 35 VARIABLE SPEED SWITCH 33 F_E EARLY AMERICAN FRONT 34 F_P PANO...

Страница 17: ...e to connect length or wire gauge Replace Open window or door Use one of the methods described in ANSI Z223 1 Section 5 3 or the applicable local code Fill the tank Service or replace Oxygen Depletion...

Страница 18: ...HI Gauge should read 7 minimum 4 5 water column for natural gas or 13 11 minimum water column for propane Outlet pressure can be checked the same as above using screw B Check with burner operating on...

Страница 19: ...ervice History This heater must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name 10 0 service history 19 W415 0204 F 10 23 08 TP SERV...

Страница 20: ...NOTES 11 0 notes 20 W415 0204 F 10 23 08 TP NOTES...

Отзывы: