Napoleon GVFL18 Скачать руководство пользователя страница 7

7

W415-0809 / B / 01.07.11

2.5  RATING PLATE INFORMATION

THIS APPLIANCE IS NOT FIELD CONVERTIBLE FOR USE WITH OTHER GASES.

b

4

b

4

ANSI Z21.11.2a-2008

WOLF STEEL LTD.

24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 4Y8 CANADA

W385-0317 / K

XXXXXX

THE RATING PLATE IS CHAINED TO THE PIEZO IGNITOR BRACKET AND SHOULD BE TUCKED 
UNDER THE ENTIRE ASSEMBLY

This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.

SAM

SSA

SAA

SA

SSA

SSSSSSSA

SAAAAAA

SSSA

SAAAA

SSSA

SA

SAA

SSSSSSSSSSSSSSSSSS

AMPLE

AM

AMPLE

MPLE

AMPLE

AM

AMPLE

AMPLE

MMMM

EEEEEEEEEEEEEE

LEEEEEEEEEEEEEE

LLLLLE

LEEEEEEEEEE

PPPPPPPPPPPPPP

AM

LLLLLLLLLLLE

LE

LE

LE

LE

LE

LEE

LLLLLLLLLLLLLLLLL

WOLF STEEL L

24 NAPOLEON RO

Содержание GVFL18

Страница 1: ...not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department In...

Страница 2: ...INFORMATION 7 3 0 INSTALLATION 8 3 1 INSTALLING IN AN UNVENTED APPLICATION 8 3 1 1 COMBUSTION AND VENTILATION AIR PROVISIONS 8 3 1 2 DETERMINING CONFINED OR UNCONFINED SPACE 8 3 2 INSTALLING IN A VEN...

Страница 3: ...r other objects must be kept a minimum 4 feet away from the front of the appliance Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect...

Страница 4: ...4 W415 0809 B 01 07 11 2 1 DIMENSIONS 2 1 1 GVFL18 2 1 2 GVFL24 2 1 3 GVFL30 20 500 13 250 24 000 26 250 24 000 13 250 30 250 22 750 13 250 1 500 24 000...

Страница 5: ...iances shall provide to each purchaser a copy of 527 CMR 30 00 upon the sale of the appliance from http www napoleonfireplaces com Webshare installation_manuals mass_requirements pdf A carbon monoxide...

Страница 6: ...as an oxygen depletion sensor ODS and is designed to turn off the appliance if not enough fresh air is available Napoleon s two vent free firebox enclosures the ZCVF 36 42 can be used to house all 3 o...

Страница 7: ...stration is for reference only Refer to the rating plate on the appliance for accurate information S A M S S A S A A S A S S A S S S S S S S A S A A A A A A S S S A S A A A A S S S A S A S A A S S S S...

Страница 8: ...s appliances which draw their input and output air from and to the outdoors Unusually tight construction is defined as construction where A Walls and ceilings exposed to the outside atmosphere have a...

Страница 9: ...and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings An unvented room appliance is recommended for use as a secondary...

Страница 10: ...ning table have the damper cut to provide a minimum permanent opening or install an alternate stop Any outside air ducts and or ash dumps in the appliance shall be permanently closed at time of applia...

Страница 11: ...NSI approved manual shut off and a union must be installed upstream within the appliance cavity D To ensure the appliance operates reliably install a sediment trap upstream of the appliance within the...

Страница 12: ...m of log 3 onto the slotted projections shown The charred face should be facing in E Position the bottom cavity of log 4 onto the bridge top right corner of fibre burner cover as shown with the charre...

Страница 13: ...the base of the appliance making sure not to block any burner ports or valve access Retain a small amount of lava rock for step 3 and if applicable step 4 B Place formed charcoal lumps around the fro...

Страница 14: ...ps shutting off have it serviced Keep burner and control compartment clean When lit for the first time the appliance will emit a slight odour for a few hours This is a normal temporary con dition caus...

Страница 15: ...ck log G Turn gas knob counter clockwise to pilot H Depress and hold gas knob while lighting the pilot with the push button ignitor Keep knob fully depressed for one minute then release If pilot does...

Страница 16: ...up or sweep into the garbage Check the appliance for broken logs and corrosion of the main burner base This procedure must be performed by a qualified service person Inspect the pilot for any visible...

Страница 17: ...E LOG 3 W135 0413 3 FRONT LOG 4 W135 0207 4 RIGHT LOG 5 W135 0208 5 LEFT CROSSOVER LOG 6 W135 0218 6 RIGHT CROSSOVER LOG 7 GL 671 LOG SET 8 W185 0024 GVFL18 GRATE 8 W185 0020 GVFL24 GRATE 8 W185 0023...

Страница 18: ...18 W415 0809 B 01 07 11 7 2 1 4 3 13 12 8 10 11 9 20 15 1 5 6 16 17...

Страница 19: ...Service or replace Oxygen Depletion Sensor System Correct piping and or regulator to provide correct pressure Ensure adequate supply pressure Pilot goes out when the gas knob is released The gas valv...

Страница 20: ...Depletion Sensor System Call the gas distributor Pilot goes out while standing Main burner is in OFF position Gas piping is undersized Turn on all gas appliances and see if pilot flame flutters dimin...

Страница 21: ...of the methods described in ANSI Z223 1 NFPA 54 or the applicable local code Not enough ventilation air Increase fresh air supply Use one of the methods described in ANSI Z223 1 NFPA 54 or the applica...

Страница 22: ...half any other liabilities with respect to the sale of this product Any damages to the burner or logs or other components due to water weather damage long periods of dampness condensation damaging che...

Страница 23: ...23 W415 0809 B 01 07 11 12 0 SERVICE HISTORY 43 1...

Страница 24: ...24 W415 0809 B 01 07 11 44 1 13 0 NOTES...

Отзывы: