Napoleon GVF36N Скачать руководство пользователя страница 18

18

W415-0297 / D / 04.03.03

Main burner goes
out; pilot stays on.

Pilot flame is not large
enough or not engulfing the
thermopile

-  service or replace Oxygen Depletion Sensor System

- correct piping and/or regulator to provide correct pressure

Thermopile shorting

- clean thermopile connection to the valve. Reconnect.

- replace Oxygen Depletion Sensor System / valve.

Remote wall switch wire is
too long; too much resist-
ance in the system.

-  shorten wire to correct length or wire gauge.

Faulty thermostat or switch.

-    replace.

Pilot burning; no
gas to main
burner; gas knob
is on 'HI'; wall
switch / thermostat
is on.

Themostat or switch is de-
fective.

-  connect a jumper wire across the wall switch terminals; if main
burner lights, replace switch / thermostat.

Main burner orifice is plugged.

-    remove stoppage in orifice.

Faulty valve.

-  replace.

Wall switch wiring is defec-
tive.

-  disconnect wires from valve. Connect a jumper wire across termi-
nals 1 & 3; if the main burner lights, check the wires for defects and
/ or replace wires.

Pilot goes out when
the gas knob is re-
leased.

The gas valve has
an interlock device
which will not allow
the pilot burner to
be lit until the ther-
mocouple has
cooled. Allow ap-
proximately 60
seconds for the
thermocouple to
cool.

System is not correctly
purged.

-  purge the gas line. If a glass door has been installed, ensure that
the door is open or removed prior to purging.

Thermocouple shorting /
faulty.

-  loosen and tighten thermocouple.
-  clean thermocouple and valve connection.
-  replace Oxygen Depletion Sensor System
-  test and replace valve.

Faulty valve.

-  replace.

Out of propane gas.

-  fill the tank.

Pilot flame is not large
enough. (Supply pressure
too low.)

-  service or replace Oxygen Depletion Sensor System

ELECTRODE

PILOT
BURNER

THERMOCOUPLE

THERMOPILE

Pilot will not light.

-  check if pilot can be lit by a match
-  check that the wire is connected to the push button ignitor.
-  check if the push button ignitor needs tightening.
-  replace the wire if the wire insulation is broken or frayed.
-  replace the electrode if the ceramic insulator is cracked or broken.
-  replace the push button ignitor.

 No spark at pilot burner

-  fill the tank.

Out of propane gas

No gas at the pilot burner

-  check that the manual valve is turned on.
-  check the pilot orifice for blockage.
-  replace the valve / Oxygen Depletion Sensor System.
-  call the gas distributor.

Main burner goes
out; pilot goes out.

Insufficient air supply

- open window or door. (Use one of the methods described in ANSI
Z223.1 Section 5.3 or the applicable local code.)

Out of propane gas.

-  fill the tank.

Pilot flame is not large
enough. (Supply pressure
too low.)

-  service or replace Oxygen Depletion Sensor System

- correct piping and / or regulator to provide correct pressure.

TROUBLE SHOOTING GUIDE

SYMPTOM

PROBLEM

TEST SOLUTION

B

EFORE

 

ATTEMPTING

 

TO

 

TROUBLESHOOT

PURGE

 

YOUR

 

UNIT

 

AND

 

INITIALLY

 

LIGHT

 

THE

 

PILOT

 

AND

 

THE

 

MAIN

 

BURNER

 

WITH

 

THE

 

GLASS

 

DOOR

 

REMOVED

.

Содержание GVF36N

Страница 1: ...iance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your build ing Immediately call your gas supplier from a neighbour s phon...

Страница 2: ...iquids Furniture or other objects must be kept a minimum of 4 feet away from the front of the firepla Do not use this heater if any part has been under water Immediately call a qualified servi technic...

Страница 3: ...company official Labour costs to the account of the prior approval of an authorized company official Labour costs to the account of the prior approval of an authorized company official Labour costs t...

Страница 4: ...de input rating shall be reduced at the rate of 4 for each additional 1 000ft Suitable for mobile home installation where the mobile home has been permanently placed on its site This heater must not b...

Страница 5: ...nd ventilation air Add the Btu hr of all fuel burning appliances located within the space such as gas furnace gas water heater etc Do not include direct vent gas appliances which draw their input and...

Страница 6: ...nstruction is defined as con struction where a Walls and ceilings exposed to the outside atmos phere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less...

Страница 7: ...This will ensure that clearance to combustibles is maintained within the cavity CAUTION CAUTION CAUTION CAUTION CAUTION The m The m The m The m The minimum clearance to inimum clearance to inimum cle...

Страница 8: ...he backing of the logo supplied and place on the screen cover as indicated FINISHING LOGO PLACEMENT HOOD FIGURE12 CATALYTIC DOOR OPEN ING AND CLOSING IF AP PLICABLE The upper lou vres must be removed...

Страница 9: ...omly place the charcoal embers along the front and sides of the log support tray in a realistic manner Fine dust found in the bottom of the bag should not be used Tear the embers into pieces and place...

Страница 10: ...op flange into the clips along the top of the louvre opening Se cure using a screw through the centre slot A CLIPS CENTRE SLOT FLANGE UPPER LOUVRES Insert the louvre tabs into the slots located at the...

Страница 11: ...rod from either side 2 Remove the curtain support plate Remove the two latch securing screws already installed position latch as shown in and re secure with the screws A socket ratchet is recommended...

Страница 12: ...e was not previously equipped with a blower route a grounded 2 wire 60hz power cable to the junction box At this point it must be strain relieved and insulated The three slots on the blower mounting b...

Страница 13: ...the receptacle Connect all wires as shown Plug the power cord back into the receptacle When installed ensure that any excess wire is contained preventing it from making contact with moving or hot ob...

Страница 14: ...f or a f or a f or a f or a fe e e e ew hour w hour w hour w hour w hours s s s s T T T T This is a normal tempor his is a normal tempor his is a normal tempor his is a normal tempor his is a normal...

Страница 15: ...eplace area must be kept clear and free of combus tible materials gasoline or other flammable vapours and liquids The flow of combustion and ventilation air must not be obstructed 1 In order to proper...

Страница 16: ...9 53 PROPANE GAS BURNER ORIFICE 19 W335 0024 HOOD 20 W565 0058 CURTAIN MESH 21 W555 0033 CURTAIN ROD 22 W080 0507 CURTAIN ROD BRACKET 23 W500 0184 CURTAIN SUPPORT PLATE 24 W630 0010 BLACK TASSELS REPL...

Страница 17: ...17 W415 0297 D 04 03 03...

Страница 18: ...open or removed prior to purging Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace Oxygen Depletion Sensor System test and replace valve Fau...

Страница 19: ...hen gas knob is turned to ON po sition Wall switch is mounted up side down reverse Faulty valve replace replace Remote wall switch is grounding check for ground short repair ground or replace wire Rem...

Страница 20: ...20 W415 0297 D 04 03 03 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Отзывы: