W415-0297 / D / 04.03.03

CERTIFIED UNDER AMERICAN NATIONAL STANDARDS, ANSI Z21.11.2, VOLUME II FOR UNVENTED ROOM HEATERS.

UNVENTED MILLIVOLT SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS FOR

UNVENTED GAS FIREPLACE

NATURAL GAS  MODEL

 

GVF36N

PROPANE GAS  MODEL

 

GVF36P

CERTIFIED FOR UNITED STATES USING ANSI METHODS

WARNING: 

 If the information in these instructions is not followed exactly, a fire or

explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicinity

of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.
•  Do not touch any electrical switch.
•  Do not use any phone in your build

ing.

•  Immediately call your gas supplier from

a neighbour's phone. Follow the gas
supplier's instructions.

•  If you cannot reach your gas supplier,

call the fire department.

Installation and service must be performed by a qualified installer, service agency or
the gas supplier.

This is an unvented gas-fired heater that uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion and ventilation air must be provided.

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031

www.napoleonfireplaces.com • [email protected]

Содержание GVF36N

Страница 1: ...iance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your build ing Immediately call your gas supplier from a neighbour s phon...

Страница 2: ...iquids Furniture or other objects must be kept a minimum of 4 feet away from the front of the firepla Do not use this heater if any part has been under water Immediately call a qualified servi technic...

Страница 3: ...company official Labour costs to the account of the prior approval of an authorized company official Labour costs to the account of the prior approval of an authorized company official Labour costs t...

Страница 4: ...de input rating shall be reduced at the rate of 4 for each additional 1 000ft Suitable for mobile home installation where the mobile home has been permanently placed on its site This heater must not b...

Страница 5: ...nd ventilation air Add the Btu hr of all fuel burning appliances located within the space such as gas furnace gas water heater etc Do not include direct vent gas appliances which draw their input and...

Страница 6: ...nstruction is defined as con struction where a Walls and ceilings exposed to the outside atmos phere have a continuous water vapour retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less...

Страница 7: ...This will ensure that clearance to combustibles is maintained within the cavity CAUTION CAUTION CAUTION CAUTION CAUTION The m The m The m The m The minimum clearance to inimum clearance to inimum cle...

Страница 8: ...he backing of the logo supplied and place on the screen cover as indicated FINISHING LOGO PLACEMENT HOOD FIGURE12 CATALYTIC DOOR OPEN ING AND CLOSING IF AP PLICABLE The upper lou vres must be removed...

Страница 9: ...omly place the charcoal embers along the front and sides of the log support tray in a realistic manner Fine dust found in the bottom of the bag should not be used Tear the embers into pieces and place...

Страница 10: ...op flange into the clips along the top of the louvre opening Se cure using a screw through the centre slot A CLIPS CENTRE SLOT FLANGE UPPER LOUVRES Insert the louvre tabs into the slots located at the...

Страница 11: ...rod from either side 2 Remove the curtain support plate Remove the two latch securing screws already installed position latch as shown in and re secure with the screws A socket ratchet is recommended...

Страница 12: ...e was not previously equipped with a blower route a grounded 2 wire 60hz power cable to the junction box At this point it must be strain relieved and insulated The three slots on the blower mounting b...

Страница 13: ...the receptacle Connect all wires as shown Plug the power cord back into the receptacle When installed ensure that any excess wire is contained preventing it from making contact with moving or hot ob...

Страница 14: ...f or a f or a f or a f or a fe e e e ew hour w hour w hour w hour w hours s s s s T T T T This is a normal tempor his is a normal tempor his is a normal tempor his is a normal tempor his is a normal...

Страница 15: ...eplace area must be kept clear and free of combus tible materials gasoline or other flammable vapours and liquids The flow of combustion and ventilation air must not be obstructed 1 In order to proper...

Страница 16: ...9 53 PROPANE GAS BURNER ORIFICE 19 W335 0024 HOOD 20 W565 0058 CURTAIN MESH 21 W555 0033 CURTAIN ROD 22 W080 0507 CURTAIN ROD BRACKET 23 W500 0184 CURTAIN SUPPORT PLATE 24 W630 0010 BLACK TASSELS REPL...

Страница 17: ...17 W415 0297 D 04 03 03...

Страница 18: ...open or removed prior to purging Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace Oxygen Depletion Sensor System test and replace valve Fau...

Страница 19: ...hen gas knob is turned to ON po sition Wall switch is mounted up side down reverse Faulty valve replace replace Remote wall switch is grounding check for ground short repair ground or replace wire Rem...

Страница 20: ...20 W415 0297 D 04 03 03 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...