11
WS-415-131 / A / 09.11.00
GD65 FAN INSTALLATION
ELECTRICAL INSTALLA-
TION TO BE DONE BY A
QUALIFIED INSTALLER
and
must be connected and
grounded in accordance with
local codes. In the absence
of local codes, use the cur-
rent ANSI/NFPA 70-1996
NA
-
TIONAL
ELECTRICAL
CODE
.
If the fireplace was not previously equipped with a
blower:
route a grounded 2-wire, 60hz power cable to the
junction box. At this point, it must be strain relieved and
insulated.
The wire harness provided in this kit is a universal har-
ness. When installed, ensure that any excess wire is con-
tained, preventing it from making contact with moving or
hot objects.
Position the vibration reducing pad into the clip and onto
the threaded stud at the other end, piercing a hole into the
pad. The fan assembly must be able to be positioned
entirely onto the pad.
Slide the fan assembly past the controls and into the clip.
Secure using the lock washer and nut provided.
Attach the connectors from the black and white wires to
the thermodisc and secure the thermodisc bracket to the
securing stud at the bottom left of the unit using a lock
washer and wing nut. Ensure that the thermodisc touches
the firebox wall.
OPTIONAL THERMOSTATIC
SENSOR
JUNCTION BOX
RECEPTACLE /
OPEN ENDED
SLOTS
BRACKET
VARIABLE SPEED/
PIEZO IGNITOR
JUNCTION BOX
THERMODISC
SENSOR ASSEMBLY
BRACKET
RECEPTACLE /
THERMOSTATIC SENSOR CONTROL
This optional kit is meant to be used only in conjunction
with the GD65 Fan Kit, which may be ordered from your
Wolf Steel /Napoleon dealer.
With the thermostatic sensor option, the fan, when turned
on, becomes thermally activated, and will automatically
run approximately 10 minutes after the fireplace has been
lit and for approximately 30-45 minutes after the fireplace
has been turned off.
Use of the fan increases the output of heat.
Unplug the power cord from the receptacle. Connect all
wires as shown.
Attach and secure the sensor assembly bracket to the
securing stud located next to the receptacle/junction box
at the bottom left of the unit using the lock washer and
wing nut. Ensure that the thermodisc touches the firebox
wall.
Plug the power cord back into the receptacle.
When installed, ensure that any excess wire is contained,
preventing it from making contact with moving or hot ob-
jects.
FIGURE 21
FIGURE 22
FIGURE 24
FIGURE 23
Содержание GVF30
Страница 19: ...19 WS 415 131 A 09 11 00 NOTES ...