W415-2164 / A / 07.21.16
5
EN
TITLE:
RATING PLATE:OPERATING & LIGHTING INSTRUCTIONS
REVISION: A CORRECTED SPELLING AND PUNCTUATION ERRORS 06.17.16_T.B.
DWG#:
W385-2161
DATE:
06.17.16
Page 1 of 2
GSS42
W385-2161 / A
CERTIFIED UNDER / HOMOLOGUÉ SELON LES NORMES: ANSI Z21.97 - CSA 2.41. OUTDOOR GAS FIREPLACE / FOYER AU GAZ EXTÉRIEUR
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
IF APPLIANCE HAS BEEN SUPPLIED WITH A GAS PRESSURE REGULATOR, IT MUST BE USED. THE
GAS SUPPLY MUST BE TURNED OFF AT THE LP-GAS SUPPLY CYLINDER WHEN THIS APPLIANCE IS
NOT IN USE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S MANUAL PROVIDED
WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT A
QUALIFIED INSTALLER, SERVICE AGENCY OR GAS SUPPLIER. MUST NOT BE USED FOR
COOKING. FOR OUTDOOR USE ONLY. IF STORED INDOORS, DETACH AND LEAVE CYLINDER
OUTDOORS.
SI L’APPAREIL EST ÉQUIPÉ D’UN RÉGULATEUR DE PRESSION D’ALIMENTATION, IL DOIT ÊTRE
UTILISÉ. LORSQUE CET APPAREIL N’EST PAS UTILISÉ, VOUS DEVEZ FERMER L’ALIMENTATION EN
GAZ SUR LA BONBONNE DE PROPANE. N’ENTREPOSEZ PAS ET N’UTILISEZ PAS D’ESSENCE
OU AUTRES LIQUIDES ET VAPEURS INFLAMMABLES À PROXIMITÉ DE CET APPAREIL OU TOUT
AUTRE APPAREIL. UNE INSTALLATION NON CONFORME, DES AJUSTEMENTS, DES
ALTÉRATIONS, UN SERVICE OU UN ENTRETIEN INADÉQUATS PEUVENT CAUSER DES
DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES CORPORELLES. RÉFÉREZ-VOUS AU
MANUEL D’INSTRUCTIONS FOURNI AVEC CET APPAREIL. POUR DE L’ASSISTANCE OU POUR
PLUS D’INFORMATION, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE AGENCE D’ENTRETIEN
OU LE FOURNISSEUR DE GAZ. NE PAS UTILISER POUR LA CUISSON. POUR USAGE
EXTÉTIEUR SEULEMENT. SI ENTREPOSÉ À L’INTÉRIEUR, DÉTACHER LA BONBONNE DE
PROPANE ET LA LAISSER À L’EXTÉRIEUR.
9700539 (WSL)
4001657 (NGZ)
4001658
(NAC) 4001659
(WUSA)
GSS42CFN MODEL GSS42CFP
0-4500FT (0-1370m)
ALTITUDE / ÉLÉVATION
0-4500FT (0-1370m)
65,000 BTU/h
INPUT / ALIMENTATION
65,000 BTU/h
40,000 BTU/h REDUCED INPUT / ALIMENTATION RÉDUITE 50,000 BTU/h
MANIFOLD PRESSURE:
3.5" WATER COLUMN
MANIFOLD PRESSURE:
10" WATER COLUMN
PRESSION AU COLLECTEUR:
3.5" D'UNE COLONNE D'EAU
PRESSION AU COLLECTEUR:
10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE:
4.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE:
4.5" D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MINIMALE:
11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE:
7.0" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE:
7.0" D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MAXIMALE:
13" D'UNE COLONNE D'EAU
NOT FOR USE WITH SOLID FUEL.
WARNING:
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE.
REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS:
TOP
18” BACK
1”
FLOOR
0“ MANTEL
NON-COMBUSTIBLE
SIDES 1”
SEE INSTALLATION INSTRUCTIONS FOR FRAMING CLEARANCES.
UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ
AVEC CET APPAREIL
AVERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION
RAPIDE. REPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL
LTÉE. N'AJOUTEZ PAS A CET APPAREIL AUCUN MATÉRIAUX DEVANT ENTRER EN CONTACT AVEC
LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES:
DESSUS
18” ARRIÈRE
1”
PLANCHER
0“ MANTEAU
INCOMBUSTIBLE
CÔTÉS 1”
POUR LES DÉGAGEMENTS AUX MATÉRIAUX D’OSSATURE, VOIR LE MANUEL D’INSTRUCTIONS.
SERIAL NUMBER/NO. DE SÉRIE:
MATERIAL:
CLASS III A-2, PERMANENT LABEL, WATERPROOF, 10 MIL VELVET GLOSS LEXAN
MIN. LETTERING FOR "
NOT FOR USE WITH SOLID FUEL.
", "
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI.
" TO BE 10 POINT ARIAL, BOLD FACE,
UPPER CASE AND 2 POINT LEADING SPACING OR EQUIVALENT.
BLACK ON WHITE BACKGROUND
MAX OVERALL DECAL SIZE: 8.5" x 4.75”
SERIAL NUMBERS TO BE ASCENDING FROM GSS42015116
A
2.3 GENERAL INFORMATION
* When the appliance is installed at elevations above 2,000ft, and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate
of 4% for each additional 1,000ft.
It is highly recommended to protect the logs from moisture (rain, snow). Cover the enclosure opening when
not in use.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
No external electricity (110 volts or 24 volts) is required for the millivolt operating system.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
2.4 RATING PLATE INFORMATION
SAMPLE
RATES AND EFFICIENCIES
NG
LP
Altitude (FT)
0-2,000 *
0-2,000
Max. Input (BTU/HR)
65,000
65,000
Min. Inlet Gas Supply Pressure
4.5" (11mb) w.c.
11" (27mb) w.c.
Max. Inlet Gas Supply Pressure
13" (32mb) w.c.
13" (32mb) w.c.
Manifold Pressure (Under Flow Conditions)
3.5" (9mb) w.c.
10" (25mb) w.c.
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.