4

W415-0158 / E / 02.19.04

4 NUTS

SHIPPING
BRACKET

GS60:

 

Maximum input is 35,000 BTU/hr for natural

gas and 31,500 BTU/hr for propane. This stove is ap-
proved for bedroom and bed-sitting room installations.

GDS60:  TOP  VENT  /  REAR  VENT
VERTICAL  TERMINATION:

 Maximum in-

put is 35,000 BTU/hr for natural gas and 31,500 BTU/hr
for propane. Maximum output for natural gas is 27,300
BTU/hr at an efficiency of 78%. Maximum output for pro-
pane is 24,570 BTU/hr at an efficiency of 78%. Maxi-
mum A.F.U.E. (annual fuel utilization efficiency) rating is
72% for natural gas and 71% for propane.

REAR  VENT  HORIZONTAL  TERMINA-
TION:

 Maximum input is 21,000 BTU/hr for natural

and propane gas. This application requires changing
the main burner orifice.
This stove is not approved for closet or recessed instal-
lations. It is approved for bathroom, bedroom and bed-
sitting room installations.
This stove may be installed in an aftermarket perma-
nently located, manufactured (mobile) home, where not
prohibited by local codes.

Change in flame appearance from "HI" to "LO" is more evi-
dent in natural gas than in propane. Expansion / contraction
noises during heating up and cooling down cycles are nor-
mal and to be expected.

This appliance is only for use with the type of gas indicated
on the rating plate. (See page 14). This appliance is not
convertible for use with other gases, unless a certified kit
is used.

INST

INST

INST

INST

INSTALLER:

ALLER:

ALLER:

ALLER:

ALLER:  It  is  y

  It  is  y

  It  is  y

  It  is  y

  It  is  your  r

our  r

our  r

our  r

our  responsib

esponsib

esponsib

esponsib

esponsiblity  to  c

lity  to  c

lity  to  c

lity  to  c

lity  to  chec

hec

hec

hec

heck  of

k  of

k  of

k  of

k  offffff   the

  the

  the

  the

  the

appropriate  box  on  the  rating  plate  according  to  the

appropriate  box  on  the  rating  plate  according  to  the

appropriate  box  on  the  rating  plate  according  to  the

appropriate  box  on  the  rating  plate  according  to  the

appropriate  box  on  the  rating  plate  according  to  the
model, venting and gas type of the unit.

model, venting and gas type of the unit.

model, venting and gas type of the unit.

model, venting and gas type of the unit.

model, venting and gas type of the unit.

Do not use abrasive cleaners to clean these parts. Buff
lightly with a clean dry cloth.
The glass is 

3

/

16

" ceramic glass available from your Napo-

leon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATE-
RIALS. Clean the glass after the first 10 hours of operation
with a recommended gas fireplace glass cleaner. Thereaf-
ter clean as required. DO NOT CLEAN GLASS WHEN HOT!
If the glass is not kept clean permanent discolouration and
/ or blemishes may result.

To avoid the stove being damaged during shipping, a ship-
ping bracket has been used and must be unbolted before
the stove can be installed.
1. Remove the four nuts holding the shipping bracket to the
bottom of the stove.
2.  Lift the stove up and away from the skid to clear the
threaded bolts sticking through the bracket. Set down on a
flat surface. The stove top is not secured to the unit.
3. 
 Discard the nuts, bracket and the skid.

FIGURE 1

THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED
BY A QUALIFIED INSTALLER
  to conform with local codes.
Installation practices vary from region to region and  it is important
to know the specifics that apply to your area,
for example: in Massachusetts State:

• The fireplace damper must be removed or welded in the open

position prior to installation of a fireplace insert or gas log.

• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or

bathroom unless the unit is a direct vent sealed combustion
product.

• WARNING: This product must be installed by a licensed plumber

or gas fitter when installed within the commonwealth of
Massachusetts.

In absence of local codes, install to the current CAN1-B149
Installation Code in Canada or to the National Fuel Gas Code,
ANSI Z223.1, and NFPA 54 in the United States. Mobile home
installation must conform with local codes. In the absence of
local codes, install to the current standard for gas equipped
mobile housing CAN/CSA Z240 MH Series in Canada or the
manufactured home construction and safety standard, Title 24
CFR, part 3280, or the Fire Safety Criteria for manufactured
home installations, Sites and Community Standard ANSI/NFPA
501A in the United States.

Purge all gas lines with the glass door of the stove removed.
Assure that a continuous gas flow is at the burner before re-
installing the door.
Under extreme vent configurations, allow several minutes (5-
15) for the flame to stabilize after ignition.
It is recommended that all horizontal runs have a ¼ inch rise
per foot.
Objects placed in front of the stove must be kept a minimum
of 48" away from the front face of the unit.

The stove and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/2 psig (3.5 kPa). The
stove must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure
testing of the gas supply piping  system at test pressures equal to
or less than ½ psig (3.5 kPa).
The stove, when installed with a blower, must be electrically
connected and grounded in accordance with local codes. In the
absence of local codes, use the current CSA C22.1 CANADIAN
ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996
NATIONAL ELECTRICAL CODE in the United States. The blower
power cord must be connected into a properly grounded receptacle.
The grounding prong must not be removed from the cord plug.

FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST-
FIRED TO ASSURE ITS OPERATION AND QUALITY!
Minimum inlet gas supply pressure is 4.5 inches water column for
natural gas and 11 inches water column for propane. Maximum
inlet gas pressure is 7 inches water column for natural gas and 13
inches water column for propane. When the valve is set to "HI", the
manifold pressure under flow conditions is 3.5 inches water column
for natural gas and 10 inches water column for propane. When the
fireplace is installed at elevations above 4,500ft, and in the absence
of specific recommendations from the local authority having juris-
diction, the certified high altitude input rating shall be reduced at the
rate of 4% for each additional 1,000ft.

GENERAL  INSTRUCTIONS

GENERAL  INFORMATION

CARE  OF  GLASS,  AND  PLATED  PARTS

SHIPPING  BRACKET

Содержание GDS60-N

Страница 1: ...88 FOR VENTED GAS FIREPLACE HEATERS Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not follo...

Страница 2: ...same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near t...

Страница 3: ...d company official Labour costs to the account of the prior approval of an authorized company official Labour costs to the account of the prior approval of an authorized company official Labour costs...

Страница 4: ...IED INSTALLER to conform with local codes Installation practices vary from region to region and it is important to know the specifics that apply to your area for example in Massachusetts State The fir...

Страница 5: ...allowtheinsidelinertobunchuponhorizontal orv orv orv orv orver er er er erticalr ticalr ticalr ticalr ticalrunsandelbows unsandelbows unsandelbows unsandelbows unsandelbows K K K K Kee ee ee ee eepitp...

Страница 6: ...nimum vertical rise is 34 inches above the stove and the maximum vertical rise is 40 feet FIGURE 4 Deviation from the minimum vertical vent length can cre ate difficulty in burner start up and or carb...

Страница 7: ...n Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to unv...

Страница 8: ...runs and elbows must be sub tracted from this maximum vertical length The maximum allowable horizontal run that B can be is 40 ft maximum vertical run length 11 ft through the roof vertical rise A 10...

Страница 9: ...off Lift the gasket off Unscrew the 4 screws securing the 4 collar and its gasket in place and remove it and the knock out from the rear panel Remove the 7 and 4 covers and gaskets from the back Posit...

Страница 10: ...lking not supplied to the framework or to the shield plate in the case of a finished wall and secure the shield through the opening to the interior wall The final location of the vent pipe shield shou...

Страница 11: ...igh temperature sealant 3 Insert the liners through the firestop vent pipe shield Holding the air terminal lettering in an upright readable position secure to the exterior wall Make weather tight by s...

Страница 12: ...l the 4 aluminum flexible liner to the stove Se cure with 3 screws and flat washers Seal the joint and screw holes using the high temperature sealant provided 3 Run a bead of high temperature sealant...

Страница 13: ...k 7 stove pipe and the Na poleon decorative brass band standard with the GS 150KT Both are available from your Napoleon dealer Attach the B Vent label shown below in the control area of the appliance...

Страница 14: ...del type depending on the installation direct vent or B vent Figure 36 For ease of accessibility an optional remote wall switch or millivolt thermostat may be installed in a convenient location Route...

Страница 15: ...front out of its retainers located at either side on the top Figure 37b 4 Open the valve control cover Pull the latch handles forward to release Figure 37c The door may now be safely removed by swing...

Страница 16: ...ed at the end of the grate as shown to prevent it from rocking Position the notch located in log 6 against the grate post 1 4 2 3 LOG PLACEMENT 5 6 Place the bottom of log 7 against the right outermos...

Страница 17: ...will quickly transform to a dull black finish during the curing process FIGURE 40 OPERATION MAINTENANCE When lit for the first time the fireplace will emit a slight odour for a few hours This is a nor...

Страница 18: ...OFF unless the knob is depressed 2 Push in gas control knob slightly and turn clock wise to off Do not force TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE CAUTION Label all w...

Страница 19: ...clockwise direction to reduce the gas flow Remove the 2 screws securing the log support bracket Natural gas models have air shutters set to 0 375 open 3 8 Propane models have air shutters set to 0 31...

Страница 20: ...5 0073_ TOP 30 W135 0068_ LEG EA 31 W135 0074 BASE PAINT FINISH ONLY 32 W010 0459 ADAPTOR C W SPILL SWITCH 33 W660 0006 SPILL SWITCH 34 W080 0405 SPILL SWITCH BRACKET 35 GD175 WALL TERMINAL KIT 36 BM6...

Страница 21: ...21 W415 0158 E 02 19 04 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 22: ...ning no gas to main burner gas knob is on HI wall switch thermostat is on Main burner orifice is plugged Faulty thermopile Faulty themostat or switch remove stoppage in orifice replace connect a jumpe...

Страница 23: ...e free of holes and well sealed at all joints check that minimum rise per foot has been adhered to for any horizontal venting Air shutter has become blocked ensure air shutter opening is free of lint...

Страница 24: ...24 W415 0158 E 02 19 04 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Отзывы: