W415-0158 / E / 02.19.04

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031

www.napoleonfireplaces.com • [email protected]

INSTALLATION  AND  OPERATION  INSTRUCTIONS  FOR:

VENTED  GAS  FIREPLACE  HEATER

NATURAL GAS MODELS

 

GDS60-N

 

and 

GS60-N

PROPANE GAS MODELS

 

GDS60-P

 

and

 

GS60-P

Model GS60 is made up of Model GDS60 and the Adapter Kit GS-150KT

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS

Installation and service must be performed by a qualified installer, service

agency or the gas supplier.

WARNING: 

 If the information in these instructions is not followed exactly, a fire or

explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the vicin-

ity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.
•  Do not touch any electrical switch.
•  Do not use any phone in your build

ing.

• Immediately call your gas supplier

from a neighbour's phone. Follow the
gas supplier's instructions.

• If you cannot reach your gas supplier,

call the fire department.

Содержание GDS60-N

Страница 1: ...88 FOR VENTED GAS FIREPLACE HEATERS Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not follo...

Страница 2: ...same room as the stove Due to high temperatures the stove should be located out of traffic and away from furniture and draperies Clothing or other flammable material should not be placed on or near t...

Страница 3: ...d company official Labour costs to the account of the prior approval of an authorized company official Labour costs to the account of the prior approval of an authorized company official Labour costs...

Страница 4: ...IED INSTALLER to conform with local codes Installation practices vary from region to region and it is important to know the specifics that apply to your area for example in Massachusetts State The fir...

Страница 5: ...allowtheinsidelinertobunchuponhorizontal orv orv orv orv orver er er er erticalr ticalr ticalr ticalr ticalrunsandelbows unsandelbows unsandelbows unsandelbows unsandelbows K K K K Kee ee ee ee eepitp...

Страница 6: ...nimum vertical rise is 34 inches above the stove and the maximum vertical rise is 40 feet FIGURE 4 Deviation from the minimum vertical vent length can cre ate difficulty in burner start up and or carb...

Страница 7: ...n Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to unv...

Страница 8: ...runs and elbows must be sub tracted from this maximum vertical length The maximum allowable horizontal run that B can be is 40 ft maximum vertical run length 11 ft through the roof vertical rise A 10...

Страница 9: ...off Lift the gasket off Unscrew the 4 screws securing the 4 collar and its gasket in place and remove it and the knock out from the rear panel Remove the 7 and 4 covers and gaskets from the back Posit...

Страница 10: ...lking not supplied to the framework or to the shield plate in the case of a finished wall and secure the shield through the opening to the interior wall The final location of the vent pipe shield shou...

Страница 11: ...igh temperature sealant 3 Insert the liners through the firestop vent pipe shield Holding the air terminal lettering in an upright readable position secure to the exterior wall Make weather tight by s...

Страница 12: ...l the 4 aluminum flexible liner to the stove Se cure with 3 screws and flat washers Seal the joint and screw holes using the high temperature sealant provided 3 Run a bead of high temperature sealant...

Страница 13: ...k 7 stove pipe and the Na poleon decorative brass band standard with the GS 150KT Both are available from your Napoleon dealer Attach the B Vent label shown below in the control area of the appliance...

Страница 14: ...del type depending on the installation direct vent or B vent Figure 36 For ease of accessibility an optional remote wall switch or millivolt thermostat may be installed in a convenient location Route...

Страница 15: ...front out of its retainers located at either side on the top Figure 37b 4 Open the valve control cover Pull the latch handles forward to release Figure 37c The door may now be safely removed by swing...

Страница 16: ...ed at the end of the grate as shown to prevent it from rocking Position the notch located in log 6 against the grate post 1 4 2 3 LOG PLACEMENT 5 6 Place the bottom of log 7 against the right outermos...

Страница 17: ...will quickly transform to a dull black finish during the curing process FIGURE 40 OPERATION MAINTENANCE When lit for the first time the fireplace will emit a slight odour for a few hours This is a nor...

Страница 18: ...OFF unless the knob is depressed 2 Push in gas control knob slightly and turn clock wise to off Do not force TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE STOVE CAUTION Label all w...

Страница 19: ...clockwise direction to reduce the gas flow Remove the 2 screws securing the log support bracket Natural gas models have air shutters set to 0 375 open 3 8 Propane models have air shutters set to 0 31...

Страница 20: ...5 0073_ TOP 30 W135 0068_ LEG EA 31 W135 0074 BASE PAINT FINISH ONLY 32 W010 0459 ADAPTOR C W SPILL SWITCH 33 W660 0006 SPILL SWITCH 34 W080 0405 SPILL SWITCH BRACKET 35 GD175 WALL TERMINAL KIT 36 BM6...

Страница 21: ...21 W415 0158 E 02 19 04 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 22: ...ning no gas to main burner gas knob is on HI wall switch thermostat is on Main burner orifice is plugged Faulty thermopile Faulty themostat or switch remove stoppage in orifice replace connect a jumpe...

Страница 23: ...e free of holes and well sealed at all joints check that minimum rise per foot has been adhered to for any horizontal venting Air shutter has become blocked ensure air shutter opening is free of lint...

Страница 24: ...24 W415 0158 E 02 19 04 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...