36
EN
W415-1328 / A / 01.05.16
5.8.6 INSTALLING FLASHING AND STORM COLLAR
SECURELY
ATTACH VENT
ADAPTER TO
FLUE COLLAR
4” (102mm)
“B” VENT
7” (178mm)
OPTIONAL
VENT PIPE
3 FT
(1m)
MIN
2 FT
(0.6m)
MIN
10 FT
(3M)
88.1A
Remove the nails from the shingles above and to the sides of
the chimney. Place the
fl
ashing over the chimney pipe and slide
underneath the sides and upper edge of the shingles. Ensure that
the chimney pipe is properly centered within the
fl
ashing, giving
a 3/4” (19.1mm) margin all around. Fasten to the roof on the top
and sides. DO NOT NAIL through the lower portion of the
fl
ashing.
Make weather-tight by sealing with caulking. Where possible, cover
the sides and top edges of the
fl
ashing with roo
fi
ng material. Apply
waterproof caulking, provided with the
fl
ashing, around the chimney,
1” (25.4mm) above the top of the
fl
ashing and push the storm collar
down into the caulking. Insert a rain cap onto the top of the last
chimney section.
RAIN CAP
CAULKING
STORM COLLAR
WEATHER
SEALANT
FLASHING