 WARNING: This is a fast acting thermocouple. It is an integral safety component.  Replace only

with a fast acting thermocouple supplied by Wolf Steel Ltd.

Содержание GDIZC - P

Страница 1: ...r gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in these instructions is not fo...

Страница 2: ...insert Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace insert It is imperative that the control compartments burners and circulating blower and its p...

Страница 3: ...uires the prior approval of an authorized company official Labour costs to the account of to the account of to the account of to the account of to the account of NAPOLEON NAPOLEON NAPOLEON NAPOLEON NA...

Страница 4: ...STALLER to con form with local codes Installation practices vary from re gion to region and it is important to know the specifics that apply to your area for example in Massachusetts State The firepla...

Страница 5: ...the fireplace in a proper workman like manner This access hole must be plugged with non combustible in sulation after the gas supply line has been installed Ensure that existing chimney cleanouts fit...

Страница 6: ...used for the intake it is necessary to adjust the primary air shutter See Air Shutter Settings on page 11 1 OUTSIDE Slip one end of a liner a minimum of 2 over one of the collars of the terminal Se cu...

Страница 7: ...Any circulation air opening may be covered with non combustible material but not sealed The insert can be equipped with either a 3 or 4 sided trim kit to finish off the fire place opening Slide the tr...

Страница 8: ...ate the clearance needed 4 Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the logs Care should be taken to shred the embers into...

Страница 9: ...you cannot reach your gas supplier call the fire depart ment When lighting and re lighting the gas knob cannot be turned from pilot to off unless the knob is depressed slightly 1 Stop Read the above s...

Страница 10: ...e blower into the clip C Secure to the threaded stud using the existing lock washer and wing nut Ensure that the blower does not touch the fireplace base or the firebox 6 Reconnect the two wires Holdi...

Страница 11: ...ctor plate shown in FIGURE 6b Bend the flap up as shown to reduce the velocity of the exhaust gases slowing down the flame pattern and creating a more traditional appearance FIGURE29 Closing the air s...

Страница 12: ...ts always give the follow ing information 1 MODEL SERIAL NUMBER OF FIREPLACE 2 INSTALLATION DATE OF FIREPLACE 3 PART NUMBER 4 DESCRIPTION OF PART 5 FINISH Contact your dealer for questions concerning...

Страница 13: ...13 W415 0223 D 01 12 04 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 14: ...ner lights check the wires for defects and or replace wires Faulty valve replace check that the manual valve is turned on check the pilot orifice for blockage replace the valve call the gas distributo...

Страница 15: ...lace glass cleaner DO NOT CLEAN GLASS WHEN HOT If deposits are not cleaned off regularly the glass may be come permanently marked Main burner goes out pilot goes out REFER TO MAIN BURNER GOES OUT PILO...

Страница 16: ...16 W415 0223 D 01 12 04 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...