1.4 GENERAL 

INSTRUCTIONS

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, 

WITH THE GLASS DOOR OPENED OR REMOVED.

PROVIDE ADEQUATE ACCESSIBILITY CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. 

PROVIDE ADEQUATE VENTILATION. 

NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.

OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THE 

FRONT FACE OF THE UNIT.

THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN 

THE COMMONWEALTH OF MASSACHUSETTS.

FIRE RISK. EXPLOSION HAZARD. 

HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS 

LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE 

TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. 

USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING 

COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.

!

WARNING

4.4

THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER

 to 

conform with local codes. Installation practices vary from region to region and  it is important to know the 
specifi cs that apply to your area, for example in Massachusetts State:
• 

The appliance damper must be removed or welded in the open position prior to installation of a appliance 
insert or gas log.

• 

The appliance off valve must be a “T” handle gas cock.

• The 

fl exible connector must not be longer than 36 inches.

• 

A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.

• 

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent 
sealed combustion product.

The installation must conform with local codes or, in 
absence of local codes, the National Gas and Propane 
Installation Code CSA B149.1 in Canada, or the 
National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the 
United States. Suitable for mobile home installation if 
installed in accordance with the current standard CAN/
CSA Z240MH Series, for gas equipped mobile homes, 
in Canada or ANSI Z223.1 and NFPA 54 in the United 
States.

As long as the required clearance to combustibles is maintained, the most desirable and benefi cial location 
for an appliance is in the center of a building, thereby allowing the most effi cient use of the heat created. 
The location of windows, doors and the traffi c fl ow in the room where the appliance is to be located should 
be considered. If possible, you should choose a location where the vent will pass through the house without 
cutting a fl oor or roof joist.

We suggest that our gas 
hearth products be installed 
and serviced by professionals 
who are certified in the U.S. 
by the National Appliance 
Institute

® (NFI) as NFI Gas 

Specialists

www.nficertified.org

Содержание GDI30

Страница 1: ...life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 2: ...NISHING 12 4 1 DOOR REMOVAL AND INSTALLATION 12 4 2 DOOR GLASS REPLACEMENT 12 4 3 GRATE INSTALLATION 13 4 4 LOG PLACEMENT 13 4 5 OPTIONAL CHARCOAL EMBERS 14 4 6 GLOWING EMBERS 14 4 7 LOGO PLACEMENT 14...

Страница 3: ...tments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system should be inspected before use and at least annually by...

Страница 4: ...f NAPOLEON with respect to the NAPOLEON gas heater and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither assumes nor au...

Страница 5: ...8 3 4 30 1 16 11 1 8 5 1 4 1 3 8 231 8 21 3 4 3 collars 13 3 4 13 3 4 Rating Plate Location 1 3 INSTALLATION OVERVIEW Venting see INSTALLATION CHIMNEY CONNECTION section Logs see FINISHING LOG PLACEME...

Страница 6: ...assachusetts State The appliance damper must be removed or welded in the open position prior to installation of a appliance insert or gas log The appliance off valve must be a T handle gas cock The fl...

Страница 7: ...re normal and to be expected MAXIMUM INPUT Is 24 500 BTU hr for natural gas and propane MAXIMUM OUTPUT For natural gas and propane is 20 825 BTU hr at an ef ficiency of 85 with the fan on The maximum...

Страница 8: ...e four inside corners beneath the log support Level using the levelling screws to eliminate rocking or excessive noise when the fan is in operation Once the appliance is level move it partially into p...

Страница 9: ...n nected to the intake collar at the appliance 2 2 2 Gently stretch the liners to the required lengths and insert into the chimney Trim and fit the flashing plate to suit the chimney termination Place...

Страница 10: ...and secure If equipped with a flex connector the appliance is designed to accept a 1 2 gas supply Without the connector it is designed to accept a 3 8 gas supply The appliance is equipped with a manua...

Страница 11: ...ONT ETC ARE CLEARLY MAINTAINED WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL THE PAINT OR LACQUER MUST BE HEAT RESISTANT TO PREVENT DISCOLOURATION This insert must be recessed into a vented noncomb...

Страница 12: ...Center the gasketed glass inside the door frame with the thick side of the gasket facing up Bend the glass retainers located along the edge of the door frame over the gasket holding the glass in place...

Страница 13: ...ckets on the back wall of the firebox The air space between the log and firebox back is used to facilitate combustion air flow 4 4 2 Move the charcoal strip into position lining up the holes in the bo...

Страница 14: ...CEMENT 4 6 GLOWING EMBERS Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs Care should be taken to shred the embers into th...

Страница 15: ...d electricity back on Because the blower is thermally activated when turned on it will automatically start approximately 5 15 minutes after lighting the appliance insert and will run for ap proximatel...

Страница 16: ...l which has been under water Turn off all gas to the appliance Open windows Do not try to light any appliance Do not touch any electric switch do not use any phone in your building GAS KNOB WARNING Th...

Страница 17: ...0 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST 39 3 P I P I L O T N O L O T HI L O F F O...

Страница 18: ...as reaches the burner 5 Replace the cleaned logs rocks or glass Failure to properly position the media may cause carboning which can be distributed in the surrounding living area 6 Check to see that...

Страница 19: ...MPONENT REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING 9 0 REPLACEMENTS COMPONENTS REF NO APPLIANCE DESCRIPTION 1 GZ552 REPLACEMENT BLOWER 2 W725 0035 NATURAL GAS VALV...

Страница 20: ...MINAL VENT KITS REF NO APPLIANCE DESCRIPTION 1 2 1 3 DOUBLE PLY ALUMINUM LINER INLET AND EXHAUST 2 3 TO 2 REDUCER 26 GDI 2320KT VENT KIT 20FT 26 GDI 2325KT VENT KIT 25FT 26 GDI 2335KT VENT KIT 35FT 2...

Страница 21: ...909K6 6 PORCELAIN BLACK WITH MARQUIS TRIM 6 GI 909F6 6 PORCELAIN GREEN WITH MARQUIS TRIM 7 GI 900K9 9 BLACK WITH MARQUIS TRIM 7 GI 900B9 9 POLISHED BRASS WITH MARQUIS TRIM 7 GI 900AB9 9 ANTIQUE BRASS...

Страница 22: ...22 W415 0806 06 28 09 3 1 4 4 4 14...

Страница 23: ...wist the pilot head to improve the flame pattern around the thermocouple Thermocouple shorting faulty Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Repla...

Страница 24: ...correct location of storm collars Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has become blocked Ensure air shutter opening is free of lint or other obstruction...

Страница 25: ...W415 0806 06 28 09 11 0 SERVICE HISTORY Appliance Service History This heater must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name 4...

Страница 26: ...26 W415 0806 06 28 09 44 1 12 0 NOTES...

Отзывы: