15
W415-0763 / B / 10.28.11
4.1.2 ADDING SECTIONS
Add chimney sections, according to the manufacturers installation instructions. The chimney must extend at
least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof, building or
obstacle within 10 feet horizontally.
59.1A
3 FT
MIN
3 FT
MIN
3 FT
MIN
3 FT
MIN
10 FT OR
MORE
LESS THAN
10 FT
FLAT ROOF
WALL
2 FT
MIN
10 FT TO
NEAREST
ROOFLINE
RIDGE
LESS THAN
10 FEET
2 FT MIN
2 FT
MIN
Содержание EPA 1100
Страница 34: ...34 W415 0763 B 10 28 11 27 20 45 30 32 33 34 40 38 16 25 39 35 29 28 13 12 15 24 26 17 36...
Страница 37: ...37 W415 0763 B 10 28 11 43 1 12 0 SERVICE HISTORY...
Страница 38: ...38 W415 0763 B 10 28 11 13 0 NOTES 44 1...
Страница 39: ...39 W415 0763 B 10 28 11 44 1...
Страница 40: ...40 W415 0763 B 10 28 11 44 1...