3.0 exterior & remote exterior pre-installation
For exterior and remote exterior installations, you must follow the instructions below before beginning installation.
For inline installations, see “remote inline pre-installation” section.
1. Insert the blower housing assembly into the exterior housing assembly. Ensure correct orientation
(Fig. 1)
.
2. Secure the blower housing assembly to the exterior housing assembly using 4 screws (supplied)
(Fig. 2)
.
Fig. 2
Fig. 3
note:
The air damper assembly must be closed when the blower is not running for the system to function correctly.
FOR EXTERIOR AND REMOTE EXTERIOR INSTALLATIONS ONLY
#9-14 Thread, RH
Hex
x 4
x 3
3. Install the air damper assembly onto the collar and secure using self-drilling screws (supplied)
(Fig. 3)
. Rotate
so that the damper closes shut when the blower is not running.
Fig. 1
Plate
IMPOR
TANT
The plate of
the air damper
assembly must
open from the
bottom. Take
care to install
in the correct
orientation so it
will open when
the blower oper-
ates. Always test
before finishing.
note:
We recommend installing the inline cover assembly and decorative cover last, after all electrical wiring is
complete. See “electrical information” section for installation instructions.
Profile View