FUEL CONVERSION FOR MODELS
BGD36/BCDV36, BGD36CF/BCDV36CF,
BGNV36/BCNV36
These kits are for use at altitudes of 0 to 4500 feet.
This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fi re, explosion or production of carbon monoxide
may result causing property damage, personal injury or loss of life. The qualifi ed service agency is
responsible for the proper installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specifi ed in the owner instructions supplied with the kit.
5.
Using a deep socket wrench, remove the main burner orifi ce. A
back-up wrench must be used on the manifold, located below the
housing to ensure that the aluminium tubing does not twist or kink.
Replace the burner orifi ce supplied using pipe thread compound.
6.
Remove the burner hood from the
pilot assembly by pulling vertically.
Use an allen key to unscrew the injector.
Replace the pilot injector with the one
supplied. Replace the pilot hood onto
the assembly ensuring key position for
proper alignment.
The fl ame opening
on the hood must align with the
thermocouple and the thermopile.
7.
Before replacing the burner
assembly, adjust the burner shutter
opening.
8.
Replace and re-secure the burner assembly
and log support, ensuring that the venturi fi ts
over the burner orifi ce.
9.
Remove the venturi access cover and
inspect to confi rm correct venturi-orifi ce
position.
10.
To convert the main valve to the desired
fuel, follow the instructions that are supplied
with the SIT regulator assembly kit.
11.
The conversion data label must be fi lled out and attached
adjacent to the valve.
12.
Turn on the gas supply and check for gas leaks by brushing on a
soap and water solution.
Do not use open fl ame.
13.
Replace the log set. Then light the pilot and main burner to ensure
that the gas lines have been purged.
14.
Close the glass viewing door. Turn on the electrical supply to the
appliance.
Purge all gas lines with the glass door open.
Assure that a continuous fl ow is at the burner before closing
the door.
Continued on reverse
:ROI6WHHO/WG1DSROHRQ5G%DUULH21/0<&DQDGD ID[ ZZZQDSROHRQILUHSODFHVFRP
PILOT
HOOD
PILOT
INJECTOR
SIT
W415-0971 / 11.17.10
W175-0164, Propane to Natural Gas (BGD/BCDV36/36CF)
W175-0280, Propane to Natural Gas (BGNV/BCNV36)
REGULATOR
ASSEMBLY
1
#47
BURNER ORIFICE
(IN KIT W175-0164)
1
#48
BURNER ORIFICE
(IN KIT W175-0280)
1
CONVERSION DATA LABEL
1
PILOT
INJECTOR
1
WARNING: Failure to position the parts in accordance with these
diagrams or failure to use only parts specifi cally approved with
this appliance may result in property damage or personal injury.
CAUTION: The gas supply shall be shut off prior to disconnecting
the electrical power, before proceeding with the conversion.
1.
Open the glass viewing door and remove the log set.
2.
Remove the 3 screws securing the burner to the log support.
3.
Remove the log support by removing the 4 screws from the fi rebox
back.
4.
Remove the burner by removing the screw from each side of the
burner.
LOG SUPPORT SCREWS
BURNER SCREWS
BURNER BRACKET SCREWS
BURNER ORIFICE
PILOT ASSEMBLY
W175-0159, Natural Gas to Propane
(BGD/BCDV36/36CF,BGNV/BCNV36)
REGULATOR
ASSEMBLY
1
#56
BURNER ORIFICE
1
CONVERSION DATA LABEL
1
PILOT
INJECTOR
1
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.