Napoleon BIPRO665-3 Скачать руководство пользователя страница 6

6  

EN

www.napoleongrills.com

N415-0542 DEC 11.18

Electrical Precautions

WARNING!

 Failure to follow these instructions could result in property damage, personal injury or

death.  

To protect against electric shock, do not immerse cord or plugs in water or other liquid.

Unplug from the outlet when not in use and before cleaning.  Allow to cool before putting on or

taking off parts.

Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the

appliance malfunctions or has been damaged in any manner.  Contact the manufacturer for repair.

Do not let the cord hang over the edge of a table or touch hot surfaces.

Do not use an outdoor cooking gas appliance for purposes other than intended.

When connecting, first connect plug to the outdoor cooking gas appliance then plug appliance into

the outlet.

Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.

Never remove the grounding plug or use with an adapter of 2 prongs.

Use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and

approved for outdoor use with a W-A marking.

BUILT IN NATURAL GAS HOOK-UP

:  The piping up to the gas grill is the responsibility of the installer and 

piping should be located as shown in the built-in instructions.  A flexible metal connector is included to 

simplify the installation of the unit.  Connect this connector to the flare fitting on the end of the manifold. 

Connect the other end of the connector to the gas piping.  Ensure that the connector does not pass 

through a wall, floor, ceiling or partition, and is protected from damage.  Do not use a hose to connect the 

unit.  It must be connected with rigid pipe, copper tube or an approved flexible metal connector which 

complies with Z21.4 /CSA 6.10 or ANSI Z21.75/CSA 6.27.
The installation must comply with CAN B149.1 Natural Gas and Propane Installation Code in Canada, or 

to the National Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be sufficiently 

sized to supply the BTU/h specified on the rating plate, based on the length of the piping run. If installing 

a side burner, a separate line must be branched off to the side burner unit and enter the side burner 

opening at the specified location.

WARNING!

 Built in units are supplied with a drip pan which holds only a minimal amount of

grease. To prevent grease fires, the pan must be cleaned after each use.

WARNING!

 Access must be provided to the inside of the enclosure to make gas connections.

DANGER!

 Read all instructions carefully before operating the grill.  Failure to follow these

instructions exactly could result in a fire causing serious injury or death. The entire installation must be 

leak tested before operating the grill.

!

!

!

N415-0542 DEC 11.18.indd   6

12/13/2018   11:03:50 AM

Содержание BIPRO665-3

Страница 1: ...r continues keep away from the appliance and immediately call your gas supplier or fire department APPLY SERIAL NUMBER LABEL FROM CARTON Serial No XXXXXX000000 MODEL NO This gas grill must be used onl...

Страница 2: ...ial or indirect damages or for any transportation charges labor costs or export duties This Limited Warranty is provided in addition to any rights afforded to you by local laws Accordingly this Limite...

Страница 3: ...other enclosed area Natural gas units must be disconnected from the supply when being stored indoors Inspect the fuel supply hose before each use If there is evidence of excessive abrasion or wear or...

Страница 4: ...r Transportation of Dangerous Goods and Commission as applicable or the Specifications for LP Gas Cylinders of the U S Department of Transportation D O T Cart models have been designed for use with a...

Страница 5: ...than 20 in2 130 cm2 for a 20 lb 9 1 kg cylinder and 30 in2 195 cm2 for a 30 lb 13 6 kg cylinder 2 At least one ventilation opening on the exposed exterior side of the enclosure located 1 in 25 4 mm or...

Страница 6: ...flexible metal connector is included to simplify the installation of the unit Connect this connector to the flare fitting on the end of the manifold Connect the other end of the connector to the gas p...

Страница 7: ...onds turn the control knob to the off position and wait 5 minutes for any excess gas to dissipate Either repeat steps 2 and 3 or light with a match 4 If the burner will not ignite within 5 seconds tur...

Страница 8: ...winds adversely affect the cooking performance of the gas grill In extreme circumstances when consistent high winds come from directly behind the unit heat can vent underneath the control panel This...

Страница 9: ...r on the inside For example a 3 pound chicken on the rotisserie will be done in approximately 1 hours on medium to high Search Grill Master Recipes at www napoleongrills com recipes for rotisserie ATT...

Страница 10: ...Cleaning Inside The Gas Grill Remove the cooking grids Use a brass wire brush to clean loose debris from the casting sides and underneath the lid Scrape the sear plates with a putty knife or scraper a...

Страница 11: ...Remove cooking grids and sear plates and leave lid open You may have to open the door or remove the top drawer if equipped to access the air shutter screw located at the mouth of the burner The back c...

Страница 12: ...other debris Reinstallation Reverse the procedure to reinstall the burner Check that the valve enters the burner when installing Replace sear plate mount and or tighten screws to complete reinstallati...

Страница 13: ...sing parts please call our Customer Solutions Department at 1 866 820 8686 between 9 AM and 5 PM Eastern Standard Time CAUTION During unpacking and assembly we recommended you wear work gloves and saf...

Страница 14: ...terials to the appliance Do not use wood or drywall W W H D W H D 1 44mm BUILT IN SIDEBURNER GAS INLET OPENING NON COMBUSTIBLE MATERIAL OUTDOOR GFI ELECTRICAL OUTLET RECOMMENDED LOCATE ON SAME SIDE OF...

Страница 15: ...18 EN www napoleongrills com N415 0542 DEC 11 18 APPLY A DAB OF SILICONE TO EACH FLANGE TO SECURE IN PLACE N415 0542 DEC 11 18 indd 18 12 13 2018 11 04 06 AM...

Страница 16: ...19 www napoleongrills com N415 0542 DEC 11 18 N415 0542 DEC 11 18 indd 19 12 13 2018 11 04 06 AM...

Страница 17: ...below the bottom of the grill as illustrated Fasten the electrical box to the inside of the enclosure making sure the ventilation holes are not obstructed Plug the power supply into a Ground Fault Int...

Страница 18: ...21 www napoleongrills com N415 0542 DEC 11 18 x1 x1 x1 NON METALIC CABINET ONLY 4 3 5 LOCATED INSIDE CABINET N415 0542 DEC 11 18 indd 21 12 13 2018 11 04 14 AM...

Страница 19: ...22 EN www napoleongrills com N415 0542 DEC 11 18 COUNTER TOP REQD NOT INCLUDED IM UGC665 N415 0542 DEC 11 18 indd 22 12 13 2018 11 04 17 AM...

Страница 20: ...23 www napoleongrills com N415 0542 DEC 11 18 N570 0038 1 4 20 X 1 2 x2 N450 0008 1 4 20 x2 IM UGC665 1 2 3 4 N415 0542 DEC 11 18 indd 23 12 13 2018 11 04 19 AM...

Страница 21: ...24 EN www napoleongrills com N415 0542 DEC 11 18 x1 x1 x2 x1 5 LOCATED INSIDE CABINET 6 7 N415 0542 DEC 11 18 indd 24 12 13 2018 11 04 23 AM...

Страница 22: ...25 www napoleongrills com N415 0542 DEC 11 18 3 1 2 N415 0542 DEC 11 18 indd 25 12 13 2018 11 04 24 AM...

Страница 23: ...26 EN www napoleongrills com N415 0542 DEC 11 18 N415 0542 DEC 11 18 indd 26 12 13 2018 11 04 26 AM...

Страница 24: ...erforming this test and remove all sources of ignition See Leak Testing Diagram for areas to check Turn all burner controls to the off position Turn gas supply valve on Brush a half and half solution...

Страница 25: ...m N415 0542 DEC 11 18 Rotisserie Kit Assembly Instruction optional Assemble rotisserie kit components as shown X Ensure stop bushing is tightened on the inside of hood casting N415 0542 DEC 11 18 indd...

Отзывы: