Napoleon BGD33NR Скачать руководство пользователя страница 27

27

W415-0341 / F / 11.21.05

L

ON/OFF

KNOB

FF

O

P

I

N

O

L

O

T

IH

PILOT

O

PILOT

ADJUSTMENT

KNOB

FLAME

After extended periods of non-operation such as fol-
lowing a vacation or a warm weather season, the fire-
place may emit a slight odour for a few hours. This is
caused by dust particles in the heat exchanger burning
off. In both cases, open a window to sufficiently venti-
late the room.

Purge all gas lines with the glass door of the fireplace
removed. Assure that a continuous gas flow is at the
burner before installing the door.
When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary con-
dition caused by the curing of the logs and the "burn-
in" of internal paints and lubricants used in the manu-
facturing process and will not occur again.

• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire de-
partment.

GAS KNOB

A.

 This fireplace is equipped with a pilot which must be lit
by hand while following these instructions exactly.

B.

 Before operating smell all around the fireplace area
for gas and next to the floor because some gas is
heavier than air and will settle on the floor.

C.

 Use only your hand to turn the gas control knob. Never

use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or
attempted repair may result in a fire or explosion.

D. 

Do not use this fireplace if any part has been under

water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under wa-
ter.

WARNING: 

The gas valve has an interlock device which

will not allow the pilot burner to be lit until the thermocou-
ple has cooled. Allow approximately 60 seconds for the
thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is 

depressed

slightly.
1.

Stop! Read the above safety information on this label.

2.

Turn off all electric power to the fireplace.

3.

Turn the gas knob clockwise              to off.

4.

Wait five (5) minutes to clear out any gas. If you smell

gas including near the floor. Stop! Follow "B" in the above
safety information on this label. If you don't smell gas go
the next step.

5.

Turn gas knob counter-clockwise                to pilot.

6.

Depress slightly and hold gas knob while lighting the

pilot with the push button ignitor. Keep knob depressed
for one minute, then release. If pilot does not continue to
burn, repeat steps 3 through 5.

7.

With pilot lit, depress and turn gas knob counter-clock-

wise                to on.

8.

If equipped with remote on-off switch/thermostat, main

burner may not come on when you turn valve to on.  Remote
switch must be in the on position to ignite burner.

9.

Turn on all electric power to

the fireplace.

1.

Turn off all electric power to the fireplace if service is to

be performed.

2.

Push in gas control knob slightly and turn clockwise to

off.              Do not force.

OPERATION / MAINTENANCE

FOR YOUR SAFETY READ BEFORE LIGHTING:

WHAT TO DO IF YOU SMELL GAS:

LIGHTING INSTRUCTIONS

TO TURN OFF GAS

TURN THE CONTROL VALVE TO THE OFF POSITION WHEN HEATER IS NOT IN USE.

FIGURE 62

FIGURE 63

Содержание BGD33NR

Страница 1: ...try to light any appliance Do not touch any electrical switch Do not use any phone in your build ing Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions...

Страница 2: ...hing or other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It is imperative that...

Страница 3: ...the prior approval of an authorized company official Labour costs to the account of the prior approval of an authorized company official Labour costs to the account of NAPOLEON NAPOLEON NAPOLEON NAPO...

Страница 4: ...on and it is important to know the specifics that apply to your area for example in Massachusetts State The fireplace damper must be removed or welded in the open position prior to installation of a f...

Страница 5: ...TERMINAL KIT GD222 VENTING LENGTHS AND AIR TERMINAL LOCATIONS VENTING The maximum allowable vertical vent length is 40 feet For optimum flame appearance and fireplace performance keep the vent length...

Страница 6: ...r ignition Six 6 inches is the minimum bend radius allowed for the 7 diameter flexible liner For optimum performance it is recommended that horizontal runs have a minimum inch rise per foot when using...

Страница 7: ...at open Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance...

Страница 8: ...i cal rise to m a x i m u m of 40 feet vertical rise is equal to or greater than the horizontal run horizontal run verti cal rise to m a x i m u m of 40 feet vertical rise is equal to or greater than...

Страница 9: ...ONS ELBOW VENT LENGTH VALUES Example 1 See graph to determine the required vertical rise VT for the required horizontal run HT For vent configurations requiring more than two 90 el bows the following...

Страница 10: ...Formula 2 HT VT 24 75 feet 20 45 24 75 Since both formulas are met this vent configuration is ac ceptable FIGURE9 For vent configurations requiring more than two 90 elbows the following formulas appl...

Страница 11: ...T VT Formula 2 HT VT 40 feet 90 90 Example 3 V1 3ft V2 8ft VT V1 V2 3 8 11 ft H1 2 5ft H2 2ft HR H1 H2 2 5 2 4 5 ft HO 03 three 90 elbows 90 03 270 90 5 4 ft HT HR HO 4 5 5 4 9 9 ft HT VT 9 9 11 20 9...

Страница 12: ...raph to determine the required ver tical rise VT for the required horizontal run HT ceptable Example 5 V1 4ft V2 1 5ft VT V1 V2 4 1 5 5 5 ft H1 2ft H2 1ft H3 1ft H4 1 5ft HR H1 H2 H3 H4 2 1 1 1 5 5 5...

Страница 13: ...03 90 90 90 90 5 4 ft HT HR HO 5 5 5 4 10 9 ft HT VT 10 9 15 25 9 ft Formula 1 HT VT 10 9 15 Formula 2 HT VT 40 feet 25 9 40 Since both formulas are met this vent configuration is ac ceptable FIGURE1...

Страница 14: ...VT 3 x 4 5 13 5 ft 16 1 13 5 Since this formula is not met this vent configuration is unac ceptable Formula 2 HT VT 40 feet 20 6 40 Since only formula 2 is met this vent configuration is unac ceptable...

Страница 15: ...e vent pipe collar down to cover up the open end of the shield and tighten This will prevent any materials such as insulation from filling up the 1 air space around the pipe For optimum performance it...

Страница 16: ...ed length taking into account the additional length needed for the finished wall surface Slip the liner a mini mum of 2 over the inner sleeve of the air terminal and secure with 3 8 screws Apply a hea...

Страница 17: ...Napoleon support ring assembly W010 0370 or equivalent noncombustible strap ping to maintain the minimum clearance to combustibles for both vertical and horizontal runs FIGURE31 5 Remove nails from th...

Страница 18: ...eather tight by sealing with caulking Where possi ble cover the sides and top edges of the flashing with roof ing material 8 Apply a heavy bead of waterproof caulking 2 inches above the flashing Slide...

Страница 19: ...IGURE37 GAS INSTALLATION MOBILE HOME INSTALLATION WIRE SIZE MAX LENGTH 14 gauge 100 feet 16 gauge 60 feet 18 gauge 40 feet FRAMING In Canada manufactured mobile home installation may be vented horizon...

Страница 20: ...D33 GD34 BGD34 FIGURE39a d FIGURE40a d GD34 Finishing must be done using a non combustible material placed flush with the front face of the unit and extending from the top of the unit Example cement b...

Страница 21: ...43 c Additional set screws may be installed TOP SLOT FINISHING MATERIAL CORNER POST NAILING TAB A B C CENTRE HOLE BGD33 NAILING TAB INSTALLATION It is best to frame your fireplace after it is position...

Страница 22: ...ombustible materials must be installed flush with the front of the fireplace but must not cover any of the black face area of the fireplace Non combustible material brick stone or ceramic tile may pro...

Страница 23: ...upport Position the top of the log into the pocket provided on the top of the rear log 1 Position the notch located in the bottom end of log 3 against the centre grate post Rest the top of log 3 into...

Страница 24: ...entre grate post Rest the top of log 3 into the pocket at the top end of log 2 Place the bottom of log 4 onto the locating pin on the right side of the log support Rest the top into the pocket pro vid...

Страница 25: ...he clips along the top of the louvre opening Secure using a screw through the centre slot NOTE Hood W335 0028 is re quired on B GD34 models Hood W335 0028 is recommended but not required on B GD33 mod...

Страница 26: ...the fireplace base or the firebox Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the se curing stud at the bottom left of the unit using a...

Страница 27: ...sult in a fire or explosion D Do not use this fireplace if any part has been under water Immediately call a qualified service technician to inspect the fireplace and replace any part of the control sy...

Страница 28: ...mmable vapours and liquids The flow of combustion and ventilation air must not be obstructed 1 In order to properly clean the burner and pilot assembly remove the logs to expose both assemblies 2 Keep...

Страница 29: ...PROPANE GAS VALVE 25 W010 0595 BURNER 29 W135 0082 LOG 5 CHARCOAL PIECE 30 W135 0182 LOG 6 23 W500 0096 FIRESTOP SPACER 32 W500 0208 RESTRICTOR PLATE ACCESSORIES FLEXIBLE VENT KITS TERMINAL KITS ROOF...

Страница 30: ...30 W415 0341 F 11 21 05 NOTE SOME PARTS NOT EXACTLY AS SHOWN...

Страница 31: ...ve replace Wall switch wiring is de fective disconnect switch wires from valve connect a jumper wire across terminals 1 3 if the main burner lights check the wires for de fects and or replace wires Pi...