W415-1698 / 12.20.16
12
EN
4.1.2 MOTOR
TESTING
NO
NO
YES
YES
Replace the PCB
Refer to section 6.2 (Control
Board Replacement)
Replace the motor
Refer to section 6.1
(Motor Replacement)
Replace the wire harness
Refer to section 6.7 (Wire
Harness Replacement)
Unplug the appliance
(If hardwired, turn off circuit breaker)
Unplug the appliance
(If hardwired, turn off circuit breaker)
Plug in the appliance and press power
button on the control panel
(If hardwired, turn on circuit breaker)
Plug in the appliance and press
power button on the control panel
(If hardwired, turn on circuit breaker)
Set multimeter to read
AC voltage
Place positive probe on the MOTOR
terminal of the PCB (Figure 4)
Disconnect the wire on the
MOTOR terminal on the PCB
Reconnect the wire into the
MOTOR terminal on the PCB
Place negative probe on the AC-N / AC-N1
terminal of the PCB (Figure 5)
Is there a voltage reading
approximately 120V AC?
Follow the wire from the motor until
you reach the plastic connectors and
disconnect them (Figure 6)
Using the female wire connector coming from
the PCB, place positive probe into the terminal
with the orange wire and the negative probe
into the terminal with the purple wire (Figure 7)
Is the voltage reading
approximately 120V AC?
START HERE
Содержание Allure NEFL100FH
Страница 7: ...W415 1698 12 20 16 7 EN...
Страница 8: ...W415 1698 12 20 16 8 EN...
Страница 11: ...W415 1698 12 20 16 11 EN FIGURES Fig 1 Fig 3 Fig 2 FLAME LED TERMINALS...
Страница 13: ...W415 1698 12 20 16 13 EN FIGURES MOTOR TERMINAL AC N1 Fig 4 Fig 5 Fig 6 Fig 7...
Страница 15: ...W415 1698 12 20 16 15 EN FIGURES AC N1 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 FAN TERMINAL...
Страница 19: ...W415 1698 12 20 16 19 EN FIGURES Fig 26 Fig 27 Fig 28...
Страница 29: ...W415 1698 12 20 16 29 EN 44 1 7 0 NOTES...