Limit 3: Options
First, circle desired option number(s) at left, below:
[001] Disable Remote Access (Allows Local Phone Access Only)
[002] Panel Programmed for Keypad Fire and/or Keypad Aux Panic
NOTE:
Refer to Panic Activation from Phone
[004] Enable Keypad Panic from Local Phone
NOTE:
Refer to Panic Activation from Phone
[008] Enable Keypad Aux Panic from Local Phone
NOTE:
Refer to Panic Activation from Phone
[016] Enable Keypad Fire Panic from Local Phone
NOTE:
Refer to Panic Activation from Phone
[032] Enable Auto-Reset Keypad (Wizard resets keypad every 90 seconds)
[064] Enable Area Select (Program for Multi-Area Systems)
[128] RESERVED - Do not program!
Then, enter 3-digit sum of circled numbers in blank boxes at right, above.
Valid data is “000” through “127”.
[Default = 000]
LIMIT 3:
*23*
#
COMMAND DATA
Limit 4: Telephone Company Answering Machine Override/”K” Keypad
(SECOND RING ACCESS FEATURE)
To enable this feature, enter “008”. To disable, enter “000”. Enter “016” to
enable the new “K-Series” style keypads.
NOTE:
Refer to Telephone Company Answering Machine Override.
[000] Disable Telephone Company Answering Machine Override
[008] Enable Telephone Company Answering Machine Override
[016] Enable "K Series" style Keypad
Limit 5: Number of Zones
NOTE:
An attempt to bypass a zone number greater than that programmed here
will result in the error message, “Invalid. Please try again.”
Limit 6: Wizard Keypad Address
NOTE:
For Napco Gemini Series Control Panels (GEM-P1632, GEM-P3200 and
GEM-P9600) Only; enter keypad address for Wizard. For Napco Express Series
Control Panels (GEM-P400, GEM-P800, XP-400 & XP-600) leave at default
“000”.
Limit 7: Enable Control Panel Type
Enter “000” for Napco Gemini Series Control Panels
(GEM-P1632, GEM-P3200
& GEM-P9600).
Enter “001” for Napco Express Series Control Panels
(GEM-P400, GEM-P800,
XP-400 & XP-600).
[Default = 014]
LIMIT 5:
*25*
#
COMMAND DATA
[Default = 000]
LIMIT 6:
*26*
#
COMMAND DATA
[Default = 000]
LIMIT 7:
*27*
#
COMMAND DATA
[Default = 000]
LIMIT 4:
*24*
#
COMMAND DATA
CONTROL-OUTPUT DESCRIPTIONS
Enter up to 8 descriptors (from Descriptor Library) for each output in brackets below. Then, enter respective 3-digit code
in box beneath each descriptor.
*41*
C O N T R O L
*
*
*
*
*
*
*
*#
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
*42*
C O N T R O L
*
*
*
*
*
*
*
*#
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
*43*
C O N T R O L
*
*
*
*
*
*
*
*#
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
NOTE:
Press
#
twice in rapid succession to Write and Read Back Data.
NOTE:
Press
#
twice in rapid succession to Write and Read Back Data.
NOTE:
Press
#
twice in rapid succession to Write and Read Back Data.