StarLink
™
SLE Series Alarm Communicators -- Installation Instructions
15
Wiring Diagram for BACKUP Reporting Configuration
GEM-X255 / GEM-P9600 / GEM-P3200 Control Panels
(+) (–)
AUX POWER
GRN
RED
BRN
GRAY
(CONTROL PANEL HOUSING)
1
2
3
4
5
6
7
8
9
10
11
12
13 14 15 16 17 18 19 20 21 22
26 27 28 29
23 24 25
33
30 31 32
GRAY
BRN
BLACK
YELL
O
W
Control Panel PC Board
16
VAC
*For StarLink module
terminals 1 and 2:
May be wired directly
to Aux Power of the
control panel when
65mA standby cur-
rent is available.
TIP RING TIP RING
TEL LINE
PHONE
HOME
PHONES
TO TELCO
RJ31X
Summary of connections:
RJ31X RED to StarLink module 10
RJ31X GREEN to StarLink module 11
RJ31X BROWN to Panel 32
RJ31X GRAY to Panel 33
Panel 30 to StarLink module 13
Panel 31 to StarLink module 12
GRN
RED
GRN
RED
RING TIP
GRN
RED
YELL
O
W
BLACK
*Refer to section "
SUPPLYING POWER
".
6
7
8
15
14
13
12
11
9 10
2* 3
4
5
1*
+12V (
–
) PGM1 PGM2 PGM3 IN1 IN2 GND IN3
RING
TIP
17
16
RTS
(R)
PANEL
TX (B)
PANEL
RX (G)
CTS
Y
StarLink Radio Terminals
PANEL
RING (+)
PANEL
TIP (–)
(STARLINK RADIO HOUSING)
Optional: When Power Supply
SLE-SMTCHG is not used,
connect Panel Aux Power to
StarLink terminals 1 and 2
(observing polarity)
16VAC
Transformer
TE
LC
O QU
AD
W
IR
E
J600
A
B
Jumper (J600)
(located only on
models SLE-CDMA-
8D and SLE-GSM-
8D-3/4G) must be
placed on "A" (top
two pins) to enable
remote downloading.