5
ArchiTech Mortise Lock & Surface-Mounted Networx Control Unit Mounting and Installation Instructions
7. TAPE ON DOOR: "SURFACE-MOUNTED NETWORX CONTROL UNIT"
TEMPLATE (WI2103)
The
Surface-Mounted Networx Control Unit
(see Fig. A on page 1) is al-
ways mounted on the inside ("protected" side) door surface.
Fold and place the template (WI2103) on the
inside door edge
. Align the
template with the "
HORIZONTAL CENTER LINE OF LEVER
" as shown on
the template. Tape the template in place.
8. MARK TEMPLATE "SURFACE-MOUNTED NETWORX CONTROL UNIT" HOLES
On the inside ("protected") door surface, mark the two
Control Unit Mounting Plate
(Fig. 8) holes using the correct mark-
ings printed on the template (if door is beveled, use correct markings for beveled doors as described in step 1).
The center of the wire passage hole was already marked on the
outside
surface in step 4; for the
inside
door surface,
mark the center of this same
5/8" Diameter Hole
. This
5/8" Diameter Hole
is used for the
Mortise Lock Motor Wire
,
Proximity Reader
and
Door Contact Sensor
wires.
Note:
This
5/8" Diameter Hole
is a thru-hole for wood doors
and an offset NON-thru-hole for fire rated metal doors (template WI2103).
Carefully remove the template.
FIG. 7: EXAMPLE OF INSIDE
DOOR EDGE (ARROW)
FIG. 8: MARK THE TWO "CONTROL UNIT
MOUNTING PLATE" HOLES (ARROWS)