The following information is

applicable only where local

ordinance permits use of your alarm
Control Center for fire detection

Controlling Your

Fire Circuit

If your alarm specialist installed

smoke detectors or heat sensing
thermostats, you have 24 hour fire
protection. This optional Fire Pro-
tection Zone is always active, even
though your system may be dis-
armed. An optional Fire Supervision
and Indicator Station on the Control
Center provides the following fire
circuit controls.

AC Power Check

If the yellow AC light on the Fire

Supervision and Indicator Station is
off, the Control Center is not receiv-
ing AC power. Press the spring-

loaded SILENCE & FIRE RESET

switch to shut off the Mini-Sounder.
Check lights to see if there is a

general power outage. If there is,
you will be operating from your
standby battery. When AC power is
restored. the Mini-Sounder will
come back on. Press the spring-
loaded switch again to silence the

Mini-Sounder.

Fire-Zone Check

The Mini-Sounder on the Fire

Supervision and Indicator Station
signals a problem on the Fire Zone.

Press the spring-loaded SILENCE

8 FIRE RESET switch to shut off the

Mini-Sounder. The red TROUBLE
light will come on until the Fire

Zone is cleared. When the zone is

restored, the Mini-Sounder will

signal again to indicate that the

Fire Zone is functional. Press the

SILENCE & FIRE RESET switch
once again to turn off the  Mini-
Sounder.

Fire-Detector Reset

After a fire alarm, the red FIRE

ALARM light will be on. Press the
SILENCE & FIRE RESET switch to
clear the smoke detectors.

Alarm/Battery Test

The fire alarm bell/siren and

standby battery should be tested
weekly. Disarm the Control Center.

Push the BATTERY & BELL TEST

switch down and listen to the bell/
siren. If the alarm sounds weak,
the battery is faulty. Call for service.

Would You Like More

Safety Informatlon?

For information on home fire de-

tection, burn safety, and home fire
safety, contact the National Fire

Protection Association, Public

Affairs Dept.05A, Battetymarch

Plaza, Quincy, MA 02269.

 If there is no Fire Supervision and Indicator Station on your Control

Center and your Fire Zone uses smoke detectors, have your alarm specialist
show you and explain the switch he has installed for resetting the smoke
detectors after an alarm.

13

Содержание MAGNUM ALERT 825 SYSTEM

Страница 1: ...0 1880 NAPCO OPERATING GUIDE FOR YOUR MAGNUM ALERT 825 MAGNUM ALERT 825HS SECURITY SYSTEM N A P C O ...

Страница 2: ...ORRY The Napco Magnum Alert 8254 825HS has such a wide variety of features that few if any security systems will ever need them all Your alarm professional has chosen appropriate features for your situation Ask him about them Your Magnum Alert 825 825HS is carefully designed and engineered to the highest indus try standards To provide optimum safety and security with this equipment we recommend th...

Страница 3: ...s be erased as after an extended power failure Mlnl Sounder Buzzer at each Napco Digit Key keypad warns that entry delay time has started It also sounds when you attempt to arm the system if a particular zone is in trouble It also verifies contact with a central station when a closing signal is sent optional Panic Buttons Two buttons and on the Digit Key keypad which will alert the central station...

Страница 4: ... power has been lost Reset indication with Key 9 see page 5 Mint Sounder l Steady Tone day zone in trouble entry delay in progress system armed with a priority zone in trouble l Beep 2 seconds system armed with any zone auto shunted or battery power low Arm Disarm Run Load Switch l Used to load program in user arm disarm codes Slide switch to the right LOAD position when entering codes refer to Se...

Страница 5: ...y is restored after you disarm the system See page 10 To perform this func tion the key must be held down until a beep is heard Key 5 DOOR CHIME This will initiate a feature that sounds a chime In the keypad each time the entry door on zone 1 is opened This feature only works when the alarm system is disarmed off To eliminate the door chime feature press this key again A lengthy chime may be reset...

Страница 6: ... what each zone protects 2 The Dlglt Key Keypad Lets you program arm disarm codes arm and disarm the system check the condition status of each zone temporarily bypass shunt individual or group of zones send an ambush alarm cancel exit entry delay test the battery and alarm devices reset the AC failure indica tion and bypass a Priority with Bypass Zone Three lights and a Mini Sounder on the Digit K...

Страница 7: ...er will beep At the keypad enter any combination of up to four digits there is no zero as follows Press l S 1 Four digit First User s Personal Code S 2 Four digit Second User s Personal Code l S 3 Four digit Third User s Personal Code l S 4 Four digit Fourth User s Personal Code After all user codes have been entered return the ARM DISARM RUN LOAD switch at the Control Center to the center RUN pos...

Страница 8: ...rily use the Fall back code to operate the system To restore personal codes see page 7 Selecting Your Codes Arming With A Zone In Trouble If the green STATUS light is flash ing at least one non 24 Hour Zone is in trouble in an open or shorted condition and incapable of being armed Count the number of flashes to determine the zone s in trouble For example if your back door is open on Zone 1 and a w...

Страница 9: ... power failure and your system does not respond to your correct code enter your pre programmed Fallback code to disarm See page 8 To identify which zone s were violated hold down Alarm History Key 2 until it beeps The red ARMED MEMORY light will flash to indicate the last alarm condition Count the number of flashes to determine which zone s require attention NOTE If an alarm occurredand the red li...

Страница 10: ...l come ON whenever you shunt one or more zones Enter your arm disarm code to arm your remaining zones The green light will go OFF and the red ARMED MEMORY light will come ON The yellow light will go OFF when you disarm again indi cating that the shunted zones are no longer shunted Note The shunt light does NOT come on when zones are auto shunted Arming With Instant Protectlon Pressing key 4 until ...

Страница 11: ...system to be monitored by a central station The built in digital communicator can transmit emergency signals to the central station 24 hours a day EMERGENCY SERVICES Police Medical Etc MONITORS YOUR SYSTEM 24 HOURS PR PREMISES ALERT 825 825HS COMMUNICATOR 11 ...

Страница 12: ...ones however must first be repaired Opening and Closing Reporting An optional feature that permits the central station to receive a signal each time the system is armed disarmed or both up to 4 individual users can be identified Central Station Rlngback The central station will acknowl edge the fact that you have armed your system by ringing back with a short beep from the Mini Sounder This is an ...

Страница 13: ...ignals a problem on the Fire Zone Press the spring loaded SILENCE 8 FIRE RESET switch to shut off the Mini Sounder The red TROUBLE light will come on until the Fire Zone is cleared When the zone is restored the Mini Sounder will signal again to indicate that the Fire Zone is functional Press the SILENCE FIRE RESET switch once again to turn off the Mini Sounder Fire Detector Reset After a fire alar...

Страница 14: ...at the assigned spot IMPORTANT Discuss these escape procedures with those who use the building 1 In a residence sleep with the bedroom doorclosed A closed door will hold back deadly smoke while you escape 2 When thefirealarm signals es cape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the window If the door is cool brace your shoulder against it and ope...

Страница 15: ...Zone Area Protected Zone Features Contacts doom wlndows etc 1 6 Central Station Optional Service Person Telephone Telephone 15 ...

Отзывы: